Dimensions [mm] Model L A B n D E F G H Without lock With lock LEKFS25Em-100m 335.5 380.5 106 210 4 100 45 LEKFS25Em-200m 435.5 480.5 206 310 6 2 240 220 LEKFS25Em-300m 535.5 580.5 306 410 8 3 360 340 LEKFS25Em-400m 635.5 680.5 406 510 8 3 360 340 LEKFS25Em-500m 735.5 780.5 506 610 10 4 480 460 35 14 LEKFS Series Battery-less Absolute (Step Motor 24 VDC) Dimensions: In-line Motor LEKFS32E
/s 1 8 l = 100mm V = 200m/s MGPL12 to 25 MGPL12 to 25 10 10 25 20 25 5 5 25 25 25 20 Load weight m (kg) Load weight m (kg) 20 20 25 16 20 20 16 16 12 16 16 16 12 12 1 1 12 12 12 0.5 10 20 30 31 50 100 101 200 300 0.5 10 20 30 31 50 100 101 200 300 Stroke (mm) Stroke (mm) MGPL32 to 63 MGPL32 to 63 50 50 Load weight m (kg) Load weight m (kg) 50, 63 50, 63 50, 63 50, 63 50, 63 32, 40 32, 40
Size: 16, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 200mm, Motor Option: None, Rod End Thread: M (Male)
Size: 16, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 200mm, Motor Option: None, Rod End Thread: Male, Mounting: -, Actuator Cable: -, Actuator Cable Length: -, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug Connector or I/O Cable Length for
T0425B-500X3 Available 150m for 10, 200m for 8, 500m for 4 and 6. Contact SMC for other lengths. Suffix -X3 to the end of part number. Ex.)
/s 30 l2 = 100mm, V = 200m/s MLGPL20, 25 MLGPL20, 25 10 10 25 25 25 20 25 20 20 Load weight m (kg) Load weight m (kg) Load weight m (kg) 20 25 20 25 20 1 10 30 31 100 101 200 300 1 10 30 31 100 101 200 300 Stroke (mm) Stroke (mm) MLGPL32 to 63 MLGPL32 to 63 30 30 50, 63 50, 63 Load weight m (kg) 50, 63 50, 63 50, 63 32, 40 32, 40 10 10 32, 40 32, 40 50, 63 32, 40 32, 40 5 10 50 51 100 101
/s 30 l2 = 100mm, V = 200m/s MLGPL20, 25 MLGPL20, 25 10 10 25 25 25 20 25 20 20 Load weight m (kg) Load weight m (kg) Load weight m (kg) 20 25 20 25 20 1 10 30 31 100 101 200 300 1 10 30 31 100 101 200 300 Stroke (mm) Stroke (mm) MLGPL32 to 63 MLGPL32 to 63 30 30 50, 63 50, 63 Load weight m (kg) 50, 63 50, 63 50, 63 32, 40 32, 40 10 10 32, 40 32, 40 50, 63 32, 40 32, 40 5 10 50 51 100 101
Size: 16, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 50mm, Motor Option: W (with Lock/Motor Cover), Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: A (10m), Controller Type - LEC, JXC: C91 (JXC91, EtherNet
Size: 16, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 50mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: A (10m), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IPâ„¢ Direct Input
Size: 16, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 50mm, Motor Option: with Lock/Motor Cover, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 10m, Controller Type - LEC, JXC: JXC91, EtherNet/IPâ„¢ Direct Input Type
Size: 16, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 50mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 10m, Controller Type - LEC, JXC: JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length
Size: 16, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 200mm, Motor Option: None, Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 8 (8m), Controller Type - LEC, JXC: 6P (LECA6, PNP, Step Data Input Type),
Size: 16, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 200mm, Motor Option: None, Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 8 (8m), Controller Type - LEC, JXC: 6P (LECA6, PNP, Step Data Input Type),
Size: 16, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 200mm, Motor Option: None, Rod End Thread: Male, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 8m, Controller Type - LEC, JXC: LECA6, PNP, Step Data Input Type, I/O Cable Length for LEC
Size: 16, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 200mm, Motor Option: None, Rod End Thread: Male, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 8m, Controller Type - LEC, JXC: LECA6, PNP, Step Data Input Type, I/O Cable Length for LEC
Size: 16, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 200mm, Motor Option: None, Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IPâ„¢ Direct Input
D. 2.9 Standard 2m Cord extension (Individual metal piping) Max. 100m 4 M5 X 0.5 Tightening nut Toothed lock washer E2E-X2D1-N (RSH50/63/80) 30 7 26 13 Indicator light Tightening nut M8 X 1 *Polyvinyl chloride round cord 3.5 (18/0.12) 2 wire Standard 2m Cord extension (Individual metal piping) Max. 200m Toothed lock washer 4 Output Circuit E2E-X1C1/3-wire E2E-X2D1-N/2-wire Brown (White) Load
15 Lever detection switch Indicator light Vinyl insulation round cord (oil proof, vibration proof) 0.14mm2, 3-wires, O.D. 2.9, Standard 2m, Cord extension (Individual metal piping), Max. 100m 4 M5 x 0.5 Tightening nut Washer with teeth E2E-X2D1-N (For RS1H50/63/80) 13 7 30 26 Vinyl insulation round cord 3.5 (18/0.12), 2-wire, Standard 2m, Cord extension (Individual metal piping), Max. 200m
15 Lever detection switch Indicator light Vinyl insulation round cord (oil proof, vibration proof) 0.14mm2, 3-wires, O.D. 2.9, Standard 2m, Cord extension (Individual metal piping), Max. 100m 4 M5 x 0.5 Tightening nut Washer with teeth E2E-X2D1-N (For RS1H50/63/80) 13 7 30 26 Vinyl insulation round cord 3.5 (18/0.12), 2-wire, Standard 2m, Cord extension (Individual metal piping), Max. 200m
CE1-R 5 5m 10 10m C 15 15m 20 20m A B CD E F G () 16 5. 5-1 17 18 5-2 19 5-3 20 6. 6-1 1 3 4 7 5 2 6 8 9 10 11 6-2 1 11 10 9 2 3 4 5 6 7 8 12 AC DC LCD 21 7. 7-1 7-1-1 1 ISO VG32 060 1m 7-1-2 M4 DIN [050] [25%85%] [1055Hz 0.75mmXYZ 2 ] 7-2 7-2-1 AC100V15AC85VAC115V 50/60Hz DC24V100.4A 2 0.75mm 2D FG0.75mm 100 FG FG 7-2-2 5m 20m5m20m CE1-H0374 22 CE1-R 20m 200m