Your search for LEY16 returned 30 result(s)
There were no hits with the full part number, but there were 14 hits in the keyword search.
There were no hits with the full part number, but there were 5 hits in the keyword search.
Product Information » New Products Search Results
Size: 16, Motor Mounting Position: L (Left), Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 50mm
Size: 16, Motor Mounting Position: Left, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 50mm, Motor Option: -, Rod End Thread: -, Mounting: -, Actuator Cable: -, Actuator Cable Length: -, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug Connector or I/O Cable Length for JXC: -
Protocol: EtherNet/IPâ„¢, Mounting: DIN Rail Mounting, Cable Connector: w/o Plug Connector, Actuator: LEY, Type: Rod Type, Body Size: 16, Bearing Type: Ball Bushing Bearing, Motor Mounting: Top Mounting Type, Lead: 16: 2.5mm; 25: 3mm; 32, 40: 4mm, Stroke: 50mm
Compatible Motor: Step Motor, Servo/24 VDC, Parallel I/O Type: PNP, I/O Cable Length: 3m, DIN Rail: Screw Mounting, Type: Rod Type, Body Size: 16, Bearing Type: Ball Bushing Bearing, Motor Mounting: Top Mounting Type, Motor Type: Step Motor (Servo/24 VDC), Lead: 16: 2.5mm; 25: 3mm; 32: 4mm, Stroke: 50mm
Protocol: 9 (EtherNet/IPâ„¢), Mounting: 8 (DIN Rail Mounting), Cable Connector: w/o Plug Connector, Actuator: LEY, Type: Rod Type, Body Size: 16, Bearing Type: L (Ball Bushing Bearing), Motor Mounting: Top Mounting Type, Lead: C (16: 2.5mm; 25: 3mm; 32, 40: 4mm), Stroke: 50mm
Size: 10, Motor Size: Standard, Lead Screw Type, mm: LEPS6: 8; LEPS10: 10, Stroke: 50mm, Motor Cable Mounting Direction: Top Entry, Actuator Cable Type: Standard Cable, Actuator Cable Length, m: 3, Controller Type: LECP6, Step Data Input Type, PNP, I/O Cable Length, m: 3, Communication Plug Connector: -, Controller Mounting: -
Size: 10, Motor Size: Standard, Lead Screw Type, mm: LEPS6: 4; LEPS10: 5, Stroke: 50mm, Motor Cable Mounting Direction: Top Entry, Actuator Cable Type: Standard Cable, Actuator Cable Length, m: 3, Controller Type: LECP6, Step Data Input Type, PNP, I/O Cable Length, m: 3, Communication Plug Connector: -, Controller Mounting: -
Size: 10, Motor Size: Standard, Lead Screw Type, mm: LEP*6: 8; LEP*10: 10, Stroke: 50mm, Motor Cable Mounting Direction: Top Entry, Actuator Cable Type: Standard Cable, Actuator Cable Length, m: 3, Controller Type: LECP6, Step Data Input Type, PNP, I/O Cable Length, m: 3, Communication Plug Connector: -, Controller Mounting: -
Size: 10, Motor Size: Compact Type, Lead Screw Type, mm: LEP*6: 4; LEP*10: 5, Stroke: 50mm, Motor Cable Mounting Direction: Top Entry, Actuator Cable Type: Standard Cable, Actuator Cable Length, m: 3, Controller Type: LECP6, Step Data Input Type, PNP, I/O Cable Length, m: 3, Communication Plug Connector: -, Controller Mounting: -
Size: 10, Motor Size: Standard, Lead Screw Type, mm: LEP*6: 4; LEP*10: 5, Stroke: 50mm, Motor Cable Mounting Direction: Top Entry, Actuator Cable Type: Standard Cable, Actuator Cable Length, m: 3, Controller Type: LECP6, Step Data Input Type, PNP, I/O Cable Length, m: 3, Communication Plug Connector: -, Controller Mounting: -
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Three body sizes
Size: 32, Bearing Type: L ( Ball Bushing Bearing), Motor Mounting: Top Mounting Type, Motor Type: Step Motor (Servo/24VDC), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 50mm, Motor Option: w/o Option, Guide Option: w/o Guide, Actuator Cable Type: S (Standard Cable), Actuator Cable Length: 3 (3m), Controller Type for (LEC, JXC): 6P (LECA6, Step Data Input Type, PNP), I
Size: 40, Bearing Type: M (Sliding Bearing), Motor Mounting: D (In-line Type), Motor Type: Step Motor (Servo/24VDC), Lead: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 50mm, Motor Option: w/o Option, Guide Option: w/o Guide, Actuator Cable Type: S (Standard Cable), Actuator Cable Length: 3 (3m), Controller Type for (LEC, JXC): 6P (LECA6, Step Data Input Type, PNP), I/O Cable
Size: 25, Bearing Type: M (Sliding Bearing), Motor Mounting: D (In-line Type), Motor Type: Step Motor (Servo/24VDC), Lead: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 50mm, Motor Option: w/o Option, Guide Option: w/o Guide, Actuator Cable Type: S (Standard Cable), Actuator Cable Length: 3 (3m), Controller Type for (LEC, JXC): 6P (LECA6, Step Data Input Type, PNP), I/O Cable
Size: 25, Bearing Type: M (Sliding Bearing), Motor Mounting: Top Mounting Type, Motor Type: Step Motor (Servo/24VDC), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 50mm, Motor Option: w/o Option, Guide Option: w/o Guide, Actuator Cable Type: S (Standard Cable), Actuator Cable Length: 3 (3m), Controller Type for (LEC, JXC): 6P (LECA6, Step Data Input Type, PNP), I/O Cable
Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 50mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: 6P (LECA6, PNP, Step Data Input Type), I/O Cable Length for LEC