Your search for LEY16 returned 30 result(s)
There were no hits with the full part number, but there were 14 hits in the keyword search.
There were no hits with the full part number, but there were 5 hits in the keyword search.
Product Information » New Products Search Results
Size: 16, Motor Mounting Position: R (Right), Motor: A [Servo Motor (24 VDC)], Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 100mm, Motor Option: None, Rod End Thread: Female, Mounting: L (Foot)
Size: 16, Motor Mounting Position: Right, Motor: A [Servo Motor (24 VDC)], Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 100mm, Motor Option: None, Rod End Thread: Female, Mounting: Foot, Actuator Cable: -, Actuator Cable Length: -, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug Connector or I/O Cable Length for JXC
Size: 16, Motor Mounting Position: R (Right), Motor: A [Servo Motor (24 VDC)], Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 200mm, Motor Option: B (w/Lock), Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 1 (1.5m), Controller Type - LEC, JXC: 6N (LECA6, NPN, Step Data Input Type), I
Size: 16, Motor Mounting Position: Right, Motor: A [Servo Motor (24 VDC)], Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 200mm, Motor Option: w/Lock, Rod End Thread: Male, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 1.5m, Controller Type - LEC, JXC: LECA6, NPN, Step Data Input Type, I/O Cable Length for LEC: 1.5m
Size: 16, Motor Mounting Position: Right, Motor: A [Servo Motor (24 VDC)], Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 200mm, Motor Option: w/Lock, Rod End Thread: Male, Mounting: Body Bottom Tapped, Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 1.5m, Controller: NPN Controller, I/O Cable Length: 1.5m, Communication Plug Connector: -, Controller Mounting
Size: 16, Motor Mounting Position: R (Right), Motor: A [Servo Motor (24 VDC)], Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 100mm, Motor Option: None, Rod End Thread: Female, Mounting: L (Foot), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: 6N (LECA6, NPN, Step Data Input Type), I/O Cable Length for LEC: 1 (1.5m
Size: 16, Motor Mounting Position: Right, Motor: A [Servo Motor (24 VDC)], Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 100mm, Motor Option: None, Rod End Thread: Female, Mounting: Foot, Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: LECA6, NPN, Step Data Input Type, I/O Cable Length for LEC: 1.5m, Controller Mounting: -,
Series LECP6 Series LECA6 Controller Actuator part number Compatible motor (Except cable specifications and actuator options) Example: Enter [LEFS16A-400] for LEFS16A-400B-R16N1 Step motor (Servo/24 VDC) P A Servo motor (24 VDC) Note 1) Option I/O cable length [m] Nil D Note 2) Screw mounting DIN rail mounting Number of step data (Points) Nil 1 3 5 Without cable 1.5 3 5 6 64 Note 2) DIN rail
Controller Actuator part number Part number except cable specifications and actuator options Example: Enter LEFS16A-400 for the LEFS16A-400B-R16N1. BC Blank controller Note) Compatible motor P Step motor (Servo/24 VDC) A Servo motor (24 VDC) Note) The dedicated software (LEC-BCW) is required.
x 125l x 150l M6 x 65l x 70l x 75l x 80l x 85l x 90l x 95l x 100l x 105l x 130l x 155l M8 x 65l x 70l x 75l x 80l x 85l x 90l x 95l x 100l x 105l x 130l x 155l M10 x 70l x 75l x 80l x 85l x 90l x 95l x 100l x 105l x 110l x 135l x 160l M10 x 80l x 85l x 90l x 95l x 100l x 105l x 110l x 115l x 120l x 145l x 170l CU 6.1 CQS 13.5 6.5 CQM 7.5 CQ2 RQ MU 12.5 9 7 D-X 20Data 8 13 12.5 7-6-31 32
x 100l x 115l 115 50 (M) 100 50 (M) M5 x 55l x 140l 140 75 (M) 55 CHKDB25 5 (M) x 60l x 165l 165 100 (M) 60 10 (M) x 65l M12 x 75l 75 CHKDB63 5 (M) 65 15 (M) x 70l x 80l 80 10 (M) 70 20 (M) x 75l x 85l 85 15 (M) 75 25 (M) 10.4 x 80l x 90l 90 20 (M) 80 30 (M) x 85l x 95l 95 25 (M) 85 35 (M) x 90l x 100l 100 30 (M) 90 40 (M) 16 x 95l x 105l 105 35 (M) 95 45 (M) x 100l x 110l 110 40 (M) 100
x 125l x 150l M6 x 65l x 70l x 75l x 80l x 85l x 90l x 95l x 100l x 105l x 130l x 155l M8 x 65l x 70l x 75l x 80l x 85l x 90l x 95l x 100l x 105l x 130l x 155l M10 x 70l x 75l x 80l x 85l x 90l x 95l x 100l x 105l x 110l x 135l x 160l M10 x 80l x 85l x 90l x 95l x 100l x 105l x 110l x 115l x 120l x 145l x 170l CU 6.1 CQS 13.5 6.5 CQM 7.5 CQ2 Courtesy of Steven Engineering, Inc.-230 Ryan
/pulse) enables remote monitoring of accumulated flow. 100l/pulse M/C A COM COM COM B DC12V GND F.G.
Main line flow control The accumulated pulse output function (100l/pulse) enables remote detection of accumulated flow. Flow control for each equipment line 100l/pulse Flow rate measurement range Machine PFA703H: 150 to 3000l/min PFA706H: 300 to 6000l/min PFA712H: 3000 to 12000l/min Machine Pulse counter Analog output (1 to 5VDC, 4 to 20mA) and switch output can also be accommodated.
/pulse) enables remote monitoring of accumulated flow. 100l/pulse M/C A COM COM COM B DC12V GND F.G.
D C D D CQ-M5 x 55L x 60L x 65L x 70L x 75L x 80L x 85L x 90L x 95L x 100L x 125L x 150L CQ-M5 x 55L x 60L x 65L x 70L x 75L x 80L x 85L x 90L x 95L x 100L x 125L x 150L CQ-M6 x 65L x 70L x 75L x 80L x 85L x 90L x 95L x 100L x 105L x 110L x 135L x 160L x 185L x 210L CQ-M8 x 75L x 80L x 85L x 90L x 95L x 100L x 105L x 110L x 115L x 120L x 145L x 170L x 195L x 220L x 245L C Model Mounting bolt