LEH LEY -X5 11LEFS !3 I/O cable length [m]* * When the driver type is selected, the cable is included. Select cable type and cable length.

LEPY LEPS LER LEH Tubing LEY -X5 LEY -X5 Order separately. Vent hole 11LEFS Reduces internal pressure fluctuation to prevent dust and water droplets from entering. Be sure to attach tubing.

LEFS v 11-LEFS v 25A-LEFS v LEFB v LEL v LEM v LEY v 25A-LEY v LEY-X5/X7 v LEYG v LES v LESH v LEPY v LEPS v LER v LEHZ v LEHZJ v LEHF v LEHS v High performance step motor (24 VDC) LEFS v LEFS v 11-LEFS v 25A-LEFS v LEFB v LEY v LEY-X5/X7 v LEYG v LES v LESH v LEPY v LEPS v Servo motor (24 VDC) Step motor (Incremental) LEFS v

Symbol Mounting screw dimensions (Distinction of stroke) Non-standard angle adjustment range -X5 3 Stroke Cushion Mounting style Rotation angle Auto switch MRQ S X X5 32 40 Non-standard angle adjustment range +5 -95 The standard angle adjustment range of 5(one side) is changed to in this type.

3) Although wire length should not affect switch function, use a wire that is 100m or shorter. 4. Monitor the internal voltage drop of the switch.

As an example, for a travel of 100m; Travel distance of the actuator per 1 pulse = 0.001 (mm) *1 100 (mm)/0.001 (mm) = 10 (pulse) *1 The travel distance of the actuator per 1 pulse is set according to the electronic gears (PA06/PA07) outlined in 5.3.4 Recommended Parameter Values by Actuator Model. If the stroke end signals (LSP, LSN) are not turned ON, an alarm may occur.

As an example, for a travel of 100m; Travel distance of the actuator per 1 pulse = 0.001 (mm) *1 100 (mm)/0.001 (mm) = 10 (pulse) *1 The travel distance of the actuator per 1 pulse is set according to the electronic gears (PA06/PA07) outlined in 5.3.4 Recommended Parameter Values by Actuator Model. If the stroke end signals (LSP, LSN) are not turned ON, an alarm may occur.

Size: 25, Motor Mounting: Top Mounting Position, Motor Type: A (Servo Motor, 24 VDC), Lead: A (LEY25, 12; LEY32, 16), Stroke: 100mm, Motor: w/o Lock, Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: Ends Tapped (Standard), Actuator Cable Length: 5m, Controller Type (LEC, JXC): 6N (LECA6, Step Data Input Type, NPN), I/O Cable Length for LEC: 5 (5m), Controller Mounting

Size: 25, Motor Mounting: Top Mounting Position, Motor Type: A (Servo Motor, 24 VDC), Lead: A (LEY25, 12; LEY32, 16), Stroke: 100mm, Motor: w/o Lock, Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: Ends Tapped (Standard), Actuator Cable Length: 5m, Controller Type (LEC, JXC): w/o Controller, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Screw Mounting

Size: 25, Motor Mounting: Top Mounting Position, Motor Type: Servo Motor, 24 VDC, Lead: LEY25, 12; LEY32, 16, Stroke: 100mm, Motor: w/o Lock, Rod End Thread: Rod End Male Thread, 1 Rod End Nut Included, Mounting: Ends Tapped (Standard), Actuator Cable Length: 5m, Controller Type (LEC, JXC): LECA6, Step Data Input Type, NPN, I/O Cable Length for LEC: 5m, Controller Mounting: DIN Rail Mounting

Size: 25, Motor Mounting: Top Mounting Position, Motor Type: Servo Motor, 24 VDC, Lead: LEY25, 12; LEY32, 16, Stroke: 100mm, Motor: w/o Lock, Rod End Thread: Rod End Male Thread, 1 Rod End Nut Included, Mounting: Ends Tapped (Standard), Actuator Cable Length: 5m, Controller Type (LEC, JXC): w/o Controller, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Screw Mounting, Communication

Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Servo motor (24 V DC), Step data (points): 64, Actuator/cable type: LEY25AA-400, I/O cable length / communication plug(m): Without I/O cable, Controller/driver mounting method: Screw mounting type

Size: 25, Motor Mounting Position: Top, Motor: A [Servo Motor (24 VDC)], Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 100mm, Motor Option: None, Rod End Thread: M (Male)

Size: 25, Motor Mounting Position: Top, Motor: A [Servo Motor (24 VDC)], Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 100mm, Motor Option: None, Rod End Thread: Male, Mounting: -, Actuator Cable: -, Actuator Cable Length: -, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug Connector or I/O Cable Length for JXC: -

Size: 25, Motor Mounting Position: Top, Motor: A [Servo Motor (24 VDC)], Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 100mm, Motor Option: None, Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: Without Cable, Actuator Cable Length: Without Cable, Controller Type - LEC, JXC: 6P (LECA6, PNP, Step Data Input Type)

Size: 25, Motor Mounting Position: Top, Motor: A [Servo Motor (24 VDC)], Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 100mm, Motor Option: None, Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: 6P (LECA6, PNP, Step Data Input Type), I/O Cable Length