SMC Corporation of America
Elite Part Number Search
Search Results "LEY25DC-50B"

Size: 25, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 50mm, Motor Option: B (w/Lock), Rod End Thread: M (Male)

Size: 25, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 50mm, Motor Option: w/Lock, Rod End Thread: Male, Mounting: -, Actuator Cable: -, Actuator Cable Length: -, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug Connector or I/O Cable Length

Size: 25, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 50mm, Motor Option: B (w/Lock), Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: 6P (LECA6, PNP, Step Data Input Type), I/

Size: 25, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 50mm, Motor Option: w/Lock, Rod End Thread: Male, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 5m, Controller Type - LEC, JXC: LECA6, PNP, Step Data Input Type, I/O Cable Length for LEC: Without

Size: 25, Motor Mounting: D (In-line Type), Motor Type: Step Motor, Servo/24 VDC, Lead: C (LEY25, 3; LEY32, 4), Stroke: 50mm, Motor: B (w/Lock), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: F (Rod Flange), Actuator Cable Length: 5m, Controller Type (LEC, JXC): 1P (LECP1, Programless Type, PNP), I/O Cable Length for LEC: 5 (5m), Controller Mounting: D (DIN Rail

Size: 25, Motor Mounting: In-line Type, Motor Type: Step Motor, Servo/24 VDC, Lead: LEY25, 3; LEY32, 4, Stroke: 50mm, Motor: w/Lock, Rod End Thread: Rod End Male Thread, 1 Rod End Nut Included, Mounting: Rod Flange, Actuator Cable Length: 5m, Controller Type (LEC, JXC): LECP1, Programless Type, PNP, I/O Cable Length for LEC: 5m, Controller Mounting: DIN Rail Mounting, Communication Plug Connector

Size: 25, Motor Mounting: D (In-line Type), Motor Type: Step Motor, Servo/24 VDC, Lead: C (LEY25, 3; LEY32, 4), Stroke: 50mm, Motor: B (w/Lock), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: F (Rod Flange), Actuator Cable Length: 5m, Controller Type (LEC, JXC): C61 (JXC61, Parallel PNP, Step Data Input Type), I/O Cable Length for LEC: w/o Cable, Controller Mounting

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, ACTUATOR, ELECTRIC ACTUATOR, IC, 25MM LE ELECTRIC ACTUATOR, 7.89376 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, ROD TYPE, ACTUATOR, ELECTRIC ACTUATOR, IC, 25MM LE ELECTRIC ACTUATOR, 7.89376 lb

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size.áDirectáor bracket mountings are available in three directionsáor types.á áThrust, speed and positioning * can beámanaged with the use o, Rod Type Electric Actuator, ELECTRIC ACTUATOR, A38, 1.67 lb

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Enclosure: IP65,

T-slot B dimension T-slot A dimension T-slot B 27.5 4H9 D 4 4 4 4 6 E 6 6 8 8 8 F 107 112 122 132 112 G 55 65 75 85 65 I 1 1 1 1 2 J 65 75 65 70 75 K 2 2 3 3 3 L 6 6 6 6 8 N 55 65 75 85 65 P 2 2 2 2 3 U 52 47 47 47 47 Model Cross section C-C LXSH2BD-50B LXSH2BD-75B LXSH2BD-100B LXSH2BD-125B LXSH2BD-150B Refer to page 301 for mounting.

T-slot B dimension T-slot A dimension T-slot B 27.5 4H9 D 4 4 4 4 6 E 6 6 8 8 8 F 107 112 122 132 112 G 55 65 75 85 65 I 1 1 1 1 2 J 65 75 65 70 75 K 2 2 3 3 3 L 6 6 6 6 8 N 55 65 75 85 65 P 2 2 2 2 3 U 52 47 47 47 47 Model Cross section C-C LXSH2BD-50B LXSH2BD-75B LXSH2BD-100B LXSH2BD-125B LXSH2BD-150B Refer to page 301 for mounting.

Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Step motor (24‑V DC servo), Step data (points): 64, Actuator/cable type: LEY25DC-50, I/O cable length / communication plug(m): Without I/O cable, Controller/driver mounting method: Screw mounting type

Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Step motor (24‑V DC servo), Step data (points): 64, Actuator/cable type: LEY25DC-150, I/O cable length / communication plug(m): Without I/O cable, Controller/driver mounting method: Screw mounting type

Note VVQ4000-50B-C8 One-touch fitting assembly for 8 VVQ4000-50B-C10 One-touch fitting assembly for 10 VVQ4000-50B-C12 One-touch fitting assembly for 12 VVQ4000-50B-N9 One-touch fitting for 5 16" VVQ4000-50B-N11 One-touch fitting for 3 8" SY9000-58A-02 at the end of part number denotes the thread type. threaded type port block assembly 1 4 SY9000-58A-03 at the end of part number denotes