Your search for LEY25 returned 30 result(s)
There were no hits with the full part number, but there were 14 hits in the keyword search.
There were no hits with the full part number, but there were 10 hits in the keyword search.
Product Information » New Products Search Results
Series MELSEC-A AJ71PT32-S3, AJ71T32-S3 A1SJ71PT32-S3 Max. 64 stations, connected to remote I/O stations (Max. 512 points). 16 outputs, 2 stations occupied. T unit Can be connected with PLC I/O card for serial transmission. EX300-TMB1For models of Mitsubishi Electric Corp. EX300-TTA1For models of OMRON Corp. EX300-TFU1For models of Fuji Electric Company Ltd.
No. of output points, 16 points Master station: PLC made by Mitsubishi Electric Corporation Series MELSEC-A AJ71PT32-S3, AJ71T32-S3 A1SJ71PT32-S3 Max. 64 stations, connected to remote I/O stations (Max. 512 points). No. of output points, 16 points. No. of sta. occupied, 2 stations Stations are counted from station 1 on the D side.
MELSECNET/MINI-S3 Data Link System Master unit: AJ71PT32-S3 AJ71T32-S3 A1SJ71PT32-S3 16 outputs, 2 occupied stations Connect to the I/O card of transmission PLC manufacturers to enable serial transmission. EX300-TMB1for Mitsubishi Electric Corporation EX300-TTA1.for OMRON corporation EX300-TFU1.for Fuji Electric Co., Ltd. EX300-T001.
Item Specification MELSECNET/MINI-S3 Data Link System Master unit: AJ71PT32-S3 AJ71T32-S3 A1SJ71PT32-S3 16 outputs, occupying two stations Connection to T unit PLC manufacturer's I/O card enables serial transmission. EX300-TMB1 ... for Mitsubishi Electric Corporation EX300-TTA1 ... for OMRON Corporation EX300-TFU1 ... for Fuji Electric Co., Ltd. EX300-T001 ...
ERR Item Specifications MELSECNET/MINI-S3 Data Link System Master unit : AJ71PT32-S3 AJ71T32-S3 A1SJ71PT32-S3 No. of output points, 16 points, No. of stations. occupied, 2 stations Connection to T unit PLC manufacturers I/O card enables serial transmission. EX300-TMB1 for Mitsubishi Electric Corporation EX300-TTA1 for OMRON Corporation EX300-TFU1 for Fuji Electric Co., Ltd.
EX300-T001General purpose MELSECNET/MINI-S3 Data Link System Master unit: AJ71PT32-S3 AJ71T32-S3 A1SJ71PT32-S3 No. of output point, 16 points No. of sta. occupied, 2 stations Each T unit has 32 control points.
Series MELSEC-A AJ71PT32-S3, AJ71T32-S3 A1SJ71PT32-S3 Max. 64 stations, connected to remote I/O stations (Max. 512 points). 16 outputs, 2 stations occupied.
Size: 40, Motor Mounting Position: Top Mounting, Lead: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 100mm, Motor Option: w/Lock/Motor Cover, Rod End Thread: Rod End Male Thread, 1 Rod End Nut is Included, Mounting: Foot, Top Mounting, Actuator Cable Type, Length: -, Controller: -, Mounting: -, I/O Cable: -, Communication Plug Connector: -
Size: 40, Motor Mounting Position: Top Mounting, Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 100mm, Motor Option: W (w/Lock/Motor Cover), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: L (Foot, Top Mounting)
A Controller type Motor type Power supply voltage Symbol Type AC servo motor (S2) Capacity Encoder LECSA1-S1 LECSA1-S3 LECSA2-S1 LECSA2-S3 LECSA2-S4 LECSB1-S5 LECSB1-S7 LECSB2-S5 LECSB2-S7 LECSB2-S8 AC servo motor (S2) 100 to 120 VAC 50/60 Hz S1 S3 S4 S5 S7 S8 100 W B Pulse input type (For absolute encoder) AC servo motor (S3) Pulse input type (For incremental encoder) Incremental AC servo
EX300-TMB1For models of Mitsubishi Electric Corporation EX300-TTA1For OMRON EX300-TFU1For Fuji Electric EX300-T001General purpose T units have 32 control points per unit No. of output points, 16 points Master station PLC made by Mitsubishi Electric Corporation Series MELSEC-A AJ71PT32-S3, AJ71T32-S3 A1SJ71PT32-S3 Max. 64 stations, connected to remote I/O stations (Max. 512 points).
Master station PLC made by Mitsubishi Electric Corporation Series MELSEC-A AJ71PT32-S3, AJ71T32-S3 A1SJ71PT32-S3 Max. 64 stations, connected to remote I/O stations (Max. 512 points). No. of output points, 16 points. No. of sta. occupied, 2 stations T unit Can be connected with PLC I/O card for serial transmission.
How to Order 25A-LEFS 32 H R S3 B 200 S 2 A2 Series compatible with secondary batteries q w e r t u !1 y i o !
Note 1) 25P Note 1) 26P 20P Side entry Side entry Side entry Connector entry direction Connector entry direction Connector entry direction P. 523 P. 527 P. 531 P. 535 Top entry Side entry Top entry Top entry Side entry Side entry Without cable S0 S1 S2 S3 U0 U1 U2 U3 S0 S1 S2 S3 0 1 2 3 U0 U1 U2 U3 U0 U1 U2 U3 S0 S1 S2 S3 Without cable Without cable With cable (1.5 m) With cable (3 m) With
Note 1) 25P Note 1) 26P 20P Side entry Side entry Side entry Connector entry direction Connector entry direction Connector entry direction P. 523 P. 527 P. 531 P. 535 Top entry Side entry Top entry Top entry Side entry Side entry Without cable S0 S1 S2 S3 U0 U1 U2 U3 S0 S1 S2 S3 0 1 2 3 U0 U1 U2 U3 U0 U1 U2 U3 S0 S1 S2 S3 Without cable Without cable With cable (1.5 m) With cable (3 m) With
3.40 3.60 3.80 4.00 4.20 4.40 4.60 4.80 5.00 5.20 5.40 5.60 5.80 6.00 6.20 6.40 6.60 6.80 7.00 7.20 S7 3.34 3.54 3.74 3.94 4.14 4.34 4.54 4.74 4.94 5.14 5.34 5.54 5.74 5.94 6.14 6.34 6.54 6.74 6.94 7.14 Motor type T7 3.31 3.51 3.71 3.91 4.11 4.31 4.51 4.71 4.91 5.11 5.31 5.51 5.71 5.91 6.11 6.31 6.51 6.71 6.91 7.11 Additional weight for lock[kg] S3:0.4/S7:0.7/T7:0.5 Series LEFS40 Stroke[