Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 300mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: 6N (LECA6, NPN, Step Data Input Type), I/O Cable Length for LEC

Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 300mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: LECA6, NPN, Step Data Input Type, I/O Cable Length for LEC: 3m, Controller

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting

T4 = 0.05 [s] T1 = V/a1 = 300/5000 = 0.06 [s], T3 = V/a2 = 300/5000 = 0.06 [s] T2 = = = 0.94 [s] L 0.5 V (T1 + T3) V 300 0.5 300 (0.06 + 0.06) 300 T4 = 0.05 [s] Therefore, the cycle time can be obtained as follows.

0 300 200 400 100 500 600 Speed [mm/s] Speed [mm/s] LEPY LEPS LEY32m LEY32m for acceleration/deceleration: 2000 mm/s2 LER 90 50 80 Lead 4: LEY32C LEH 40 42 Horizontal work load [kg] Vertical work load [kg] 70 Lead 4: LEY32C LEY -X5 60 Lead 8: LEY32B 30 50 11LEFS 40 20 21 Lead 8: LEY32B 30 11LEJS Lead 16: LEY32A 20 10 Lead 16: LEY32A 10 25A0 0 0 300 200 400 100 500 600 0 300 200 400 100 500

T4 = 0.05 [s] T1 = V/a1 = 300/5000 = 0.06 [s], T3 = V/a2 = 300/5000 = 0.06 [s] T2 = = = 0.94 [s] L 0.5 V (T1 + T3) V 300 0.5 300 (0.06 + 0.06) 300 T4 = 0.05 [s] Therefore, the cycle time can be obtained as follows.

T1 = V/a1 = 300/5000 = 0.06 [s], T3 = V/a2 = 300/5000 = 0.06 [s] T2 = = = 0.94 [s] L 0.5 V (T1 + T3) V 300 0.5 300 (0.06 + 0.06) 300 T4 = 0.05 [s] Therefore, the cycle time can be obtained as follows.

900 50 900 25 900 8 150 1000 75 1000 38 1000 9 200 1200 100 1200 50 1200 10 250 1400 125 1400 63 1400 11 300 1600 150 1600 75 1600 12 350 1800 175 1800 88 1800 13 400 2000 200 2000 100 2000 14 450 2500 225 2500 113 2500 15 500 3000 250 3000 125 3000 LEY32A LEYG32A LEY32B LEYG32B LEY25C LEYG32C 2] 2] 2] [mm/s] [mm/s [mm/s] [mm/s [mm/s] [mm/s 0 24 200 12 200 6 200 1 32 300 19 300 15 300 2

30 50 100 150 200 250 300 350 400 30 50 100 150 200 250 300 350 400 450 500 (kg) 0.580.62 0.73 0.87 0.98 1.09 1.20 1.181.25 1.42 1.68 1.86 2.03 2.21 2.382.56 2.09 2.20 2.49 2.77 3.17 3.46 3.74 4.03 4.32 4.60 4.89 LEY 16 D LEY 25 D LEY 32 D [mm] 1) 30 50 100 150 200 250 300 30 50 100 150 200 250 300 350 400 30 50 100 150 200 250 300 350 400 450 500 (kg) 0.580.62 0.73 0.87 0.98 1.09 1.20

Series MELSEC-A AJ71PT32-S3, AJ71T32-S3 A1SJ71PT32-S3 Max. 64 stations, connected to remote I/O stations (Max. 512 points). 16 outputs, 2 stations occupied. T unit Can be connected with PLC I/O card for serial transmission. EX300-TMB1For models of Mitsubishi Electric Corp. EX300-TTA1For models of OMRON Corp. EX300-TFU1For models of Fuji Electric Company Ltd.

750 150 300 450 600 750 150 300 450 600 750 150 300 450 600 750 SY3120 -C6 Cv = 0.23 SY5120 -01 Cv = 0.59 SY7120 -02 Cv = 0.87 SY9120 -03 Cv = 2.1 The speed of CJ2 and CM2 cylinders is controlled by a fixed orifice built into the cylinder.

EX300-T001General purpose MELSECNET/MINI-S3 Data Link System Master unit: AJ71PT32-S3 AJ71T32-S3 A1SJ71PT32-S3 No. of output point, 16 points No. of sta. occupied, 2 stations Each T unit has 32 control points.

Item Specification MELSECNET/MINI-S3 Data Link System Master unit: AJ71PT32-S3 AJ71T32-S3 A1SJ71PT32-S3 16 outputs, occupying two stations Connection to T unit PLC manufacturer's I/O card enables serial transmission. EX300-TMB1 ... for Mitsubishi Electric Corporation EX300-TTA1 ... for OMRON Corporation EX300-TFU1 ... for Fuji Electric Co., Ltd. EX300-T001 ...

ERR Item Specifications MELSECNET/MINI-S3 Data Link System Master unit : AJ71PT32-S3 AJ71T32-S3 A1SJ71PT32-S3 No. of output points, 16 points, No. of stations. occupied, 2 stations Connection to T unit PLC manufacturers I/O card enables serial transmission. EX300-TMB1 for Mitsubishi Electric Corporation EX300-TTA1 for OMRON Corporation EX300-TFU1 for Fuji Electric Co., Ltd.

No. of output points, 16 points Master station: PLC made by Mitsubishi Electric Corporation Series MELSEC-A AJ71PT32-S3, AJ71T32-S3 A1SJ71PT32-S3 Max. 64 stations, connected to remote I/O stations (Max. 512 points). No. of output points, 16 points. No. of sta. occupied, 2 stations Stations are counted from station 1 on the D side.

Series MELSEC-A AJ71PT32-S3, AJ71T32-S3 A1SJ71PT32-S3 Max. 64 stations, connected to remote I/O stations (Max. 512 points). 16 outputs, 2 stations occupied.