LEC Speed [mm/s] Speed [mm/s] LEC S LEY32m LEY32m for acceleration/deceleration: 2000 mm/s2 90 50 LEC SS-T 80 Lead 4: LEY32C 40 43 Horizontal work load [kg] LEC Y 70 Vertical work load [kg] Lead 4: LEY32C 60 Lead 8: LEY32B 30 Motorless 50 Lead 8: LEY32B 22 40 20 LAT 30 Lead 16: LEY32A 11 20 10 LZ Lead 16: LEY32A 10 0 0 LC3F2 0 300 200 400 100 500 600 0 300 200 400 100 500 600 Speed [mm/s
0 300 200 400 100 500 600 Speed [mm/s] Speed [mm/s] LEPY LEPS LEY32m LEY32m for acceleration/deceleration: 2000 mm/s2 LER 90 50 80 Lead 4: LEY32C LEH 40 42 Horizontal work load [kg] Vertical work load [kg] 70 Lead 4: LEY32C LEY -X5 60 Lead 8: LEY32B 30 50 11LEFS 40 20 21 Lead 8: LEY32B 30 11LEJS Lead 16: LEY32A 20 10 Lead 16: LEY32A 10 25A0 0 0 300 200 400 100 500 600 0 300 200 400 100 500
400 600 800 1000 1200 0 200 400 600 800 1000 1200 Speed [mm/s] Speed [mm/s] LEY32lV7 (Motor mounting position: Top/Parallel) Vertical Horizontal 50 80 Lead 5: LEY32C Lead 5: LEY32C 40 60 Lead 10: LEY32B Regenerative resistor area Work load [kg] Work load [kg] 30 Lead 10: LEY32B 40 Lead 20: LEY32A 20 Lead 20: LEY32A 20 10 0 0 0 200 400 600 800 1000 1200 1400 0 200 400 600 800 1000 1200 1400
VAC For single phase 200 VAC L1 CNP1 NFB MC CNP3 L1 CNP1 NFB MC CNP3 Single phase 200 to 230 VAC Three phase 200 to 230 VAC L2 L2 U U U Motor V U Motor V L3 L3 V V W M N () W M N W W P1 P1 PE PE P2 P2 CNP2 CNP2 P (+) P Regeneration option Regeneration option C C D D Detector Detector CN2 CN2 L11 L11 L21 L21 Note) For single phase 200 to 230 VAC, power supply should be connected to L1 and
After returning to the origin position, the SETON and INP signals are output. 0 Absolute: 200 Operation w [Specify Step No.2 to input the DRIVE signal.] 200 Absolute: 100 Step data No. defining operation The operation starts by specifying a registered step data No. to input the DRIVE signal.
/ USB 120.3 120.3 mm mm 200 200 mm/s mm/s 100 500 100 500 1 1 200 1000 200 1000 2 2 CN4 50 200 50 200 3 3 CN3 CN2 CN1 DC24V /P.9 2.1 P.13 3.1 () AWG20(0.5mm 2) 8mm C24VM24VEMG DC24V OV UL ,UL1310 Class2 (DC24V) DC24V 24V 0V 0V M24V C24V EMG (DC24V) DC24V 24V 0V 0V M24V C24V EMG 1.2 (1) /CD-ROM (PDF) (2) ACT Controller -4- Easy OK (3) ON OK OFF OK SVRE ALARM
Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: NPN, Motor Type: Step motor (24‑V DC servo), Step data (points): 64, Actuator/cable type: LEY32C-300, I/O cable length / communication plug(m): 3, Controller/driver mounting method: DIN rail mounting type
Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Step motor (24‑V DC servo), Step data (points): 64, Actuator/cable type: LEY32C-100, I/O cable length / communication plug(m): 5, Controller/driver mounting method: DIN rail mounting type
Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Step motor (24‑V DC servo), Step data (points): 64, Actuator/cable type: LEY32C-30, I/O cable length / communication plug(m): Without I/O cable, Controller/driver mounting method: Screw mounting type
Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Step motor (24‑V DC servo), Step data (points): 64, Actuator/cable type: LEY32C-100, I/O cable length / communication plug(m): Without I/O cable, Controller/driver mounting method: Screw mounting type
Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Step motor (24‑V DC servo), Step data (points): 64, Actuator/cable type: LEY32C-100, I/O cable length / communication plug(m): Without I/O cable, Controller/driver mounting method: DIN rail mounting type
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 50mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 1 (1.5m), Controller Type - LEC, JXC: 6N (LECA6, NPN, Step Data Input Type), I/O Cable Length
Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 400mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 1 (1.5m), Controller Type - LEC, JXC: 6N (LECA6, NPN, Step Data Input Type), I/O Cable Length
Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 100mm, Motor Option: B (w/Lock), Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 1 (1.5m), Controller Type - LEC, JXC: 6N (LECA6, NPN, Step Data Input Type), I/O Cable