Your search for LEY32 returned 30 result(s)
There were no hits with the full part number, but there were 14 hits in the keyword search.
There were no hits with the full part number, but there were 8 hits in the keyword search.
Product Information » New Products Search Results
)] Stroke 4 [2] 2 [4] (142) [Origin] Note 4) Origin Note 3) 65 6.5 30 79 Motor cable (2 x 5) 60 46.8 Motor option: With lock Step motor Servo motor 7.5 M4 x 0.7 thread depth 8 (F.G. terminal) Cable length y 250 (194) 65 15 15 20 20 24 20 5H9 depth 5 ( ) 0.030 0 24 20 Lock cable (3.5) n x 5.5 [mm] 6 Model L 582 634 682 734 782 834 882 934 982 1034 1082 1134 A B n D E LEFS32;-300 LEFS32;-300B
20 Lead 16: LEY32DA 20 10 0 0 0 200 400 600 800 1000 1200 0 200 400 600 800 1000 1200 Speed [mm/s] Speed [mm/s] Regenerative resistor area Applicable Motor/Driver * When using the actuator in the Regenerative resistor area, download the AC servo capacity selection program/SigmaJunmaSize+ from the SMC website.
LEL 20 LEM 0 LEY LEY 0 200 400 600 800 1000 1400 1200 Speed [mm/s] LES LEY32 (Motor mounting position: Top/Parallel) LEY32D (Motor mounting position: In-line) LEPY LEPS 80 80 Lead 4: LEY32DC Lead 5: LEY32C LER Lead 8: LEY32DB 60 60 Lead 10: LEY32B Work load [kg] Work load [kg] Lead 16: LEY32DA LEH Area where the regeneration option is required.
Motor mounting position: Top/Parallel, In-line) 40 Lead 3: LEY25C 30 Work load [kg] 20 Lead 6: LEY25B 16 Lead 12: LEY25A 10 8 0 0 200 600 1000 1400 Speed [mm/s] LEY32l (Motor mounting position: Top/Parallel) LEY32D (Motor mounting position: In-line) 50 60 Lead 4: LEY32DC 50 Lead 5: LEY32C 40 46 37 40 Work load [kg] Work load [kg] 30 30 Lead 8: LEY32DB Lead 10: LEY32B 20 24 19 20 Lead 16: LEY32DA
LEL 20 LEM 0 LEY LEY 0 200 400 600 800 1000 1400 1200 Speed [mm/s] LES LEY32 (Motor mounting position: Top/Parallel) LEY32D (Motor mounting position: In-line) LEPY LEPS 80 80 Lead 4: LEY32DC Lead 5: LEY32C LER Lead 8: LEY32DB 60 60 Lead 10: LEY32B Work load [kg] Work load [kg] Lead 16: LEY32DA LEH Area where the regeneration option is required.
Size: 32, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 300mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 8 (8m), Controller Type - LEC, JXC: 6P (LECA6, PNP, Step Data Input Type),
Size: 32, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 500mm, Motor Option: B (w/Lock), Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 8 (8m), Controller Type - LEC, JXC: 6P (LECA6, PNP, Step Data Input Type
Size: 32, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 300mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 8m, Controller Type - LEC, JXC: LECA6, PNP, Step Data Input Type, I/O Cable Length for
Size: 32, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 500mm, Motor Option: w/Lock, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 8m, Controller Type - LEC, JXC: LECA6, PNP, Step Data Input Type, I/O Cable Length for
When an analog output unit or analog input unit is connected to Slot 0, and channel 0 needs to be changed to analog range 4-20mA. 3) Select Channel0 (Sub Index 01) from the Slot _AnalogRange (Index 300B) folder.
Note No intermediate bracket is attached to IZS30-300B (SB), IZS30-780B (SB)). Intermediate bracket A. Tap M5 thread on the brackets mounting positions at the installation side, and fix the ionizer body and brackets with M5 threads. M5 tap M5 threads 4. Adjust angle of the ionizer body to ensure proper static charge elimination, and fix it with detent threads (M5) of brackets.
Please contact us for the latest version.sales@ocaire.com, CL1TF140-300B, ACTUATOR, CL1 TIE-ROD CYLINDER, UD, 140MM CL1 DOUBLE-ACTING, .00000 lb, SeriesDescriptionModelActionNoteVol. no. (for std model)CLLocked-up cylinderCL1Double acting, Single rodApplicable to ?125 to 160999
Size: 32, Bearing Type: L ( Ball Bushing Bearing), Motor Mounting: D (In-line Type), Motor Type: Step Motor (Servo/24VDC), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 300mm, Motor Option: B (with Lock), Guide Option: w/o Guide, Actuator Cable Type: R (Robotic Cable - Flexible cable), Actuator Cable Length: 8 (8m), Controller Type for (LEC, JXC): 6P (LECA6, Step Data
Size: 32, Bearing Type: Ball Bushing Bearing, Motor Mounting: In-line Type, Motor Type: Step Motor (Servo/24VDC), Lead: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 300mm, Motor Option: with Lock, Guide Option: w/o Guide, Actuator Cable Type: Robotic Cable - Flexible cable, Actuator Cable Length: 8m, Controller Type for (LEC, JXC): w/Controller, PNP, I/O Cable Length for LEC:
Size: 32, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 300mm, Motor Option: B (w/Lock)
Size: 32, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 300mm, Motor Option: w/Lock, Rod End Thread: -, Mounting: -, Actuator Cable: -, Actuator Cable Length: -, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug Connector or I/O Cable Length for