Your search for LEY32 returned 30 result(s)
There were no hits with the full part number, but there were 14 hits in the keyword search.
There were no hits with the full part number, but there were 8 hits in the keyword search.
Product Information » New Products Search Results
20 Lead 16: LEY32DA 20 10 0 0 0 200 400 600 800 1000 1200 0 200 400 600 800 1000 1200 Speed [mm/s] Speed [mm/s] Regenerative resistor area Applicable Motor/Driver * When using the actuator in the Regenerative resistor area, download the AC servo capacity selection program/SigmaJunmaSize+ from the SMC website.
LEL 20 LEM 0 LEY LEY 0 200 400 600 800 1000 1400 1200 Speed [mm/s] LES LEY32 (Motor mounting position: Top/Parallel) LEY32D (Motor mounting position: In-line) LEPY LEPS 80 80 Lead 4: LEY32DC Lead 5: LEY32C LER Lead 8: LEY32DB 60 60 Lead 10: LEY32B Work load [kg] Work load [kg] Lead 16: LEY32DA LEH Area where the regeneration option is required.
Motor mounting position: Top/Parallel, In-line) 40 Lead 3: LEY25C 30 Work load [kg] 20 Lead 6: LEY25B 16 Lead 12: LEY25A 10 8 0 0 200 600 1000 1400 Speed [mm/s] LEY32l (Motor mounting position: Top/Parallel) LEY32D (Motor mounting position: In-line) 50 60 Lead 4: LEY32DC 50 Lead 5: LEY32C 40 46 37 40 Work load [kg] Work load [kg] 30 30 Lead 8: LEY32DB Lead 10: LEY32B 20 24 19 20 Lead 16: LEY32DA
LEL 20 LEM 0 LEY LEY 0 200 400 600 800 1000 1400 1200 Speed [mm/s] LES LEY32 (Motor mounting position: Top/Parallel) LEY32D (Motor mounting position: In-line) LEPY LEPS 80 80 Lead 4: LEY32DC Lead 5: LEY32C LER Lead 8: LEY32DB 60 60 Lead 10: LEY32B Work load [kg] Work load [kg] Lead 16: LEY32DA LEH Area where the regeneration option is required.
Size: 32, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 50mm, Motor Option: None, Rod End Thread: M (Male)
Size: 32, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 50mm, Motor Option: None, Rod End Thread: Male, Mounting: -, Actuator Cable: -, Actuator Cable Length: -, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug Connector or I/O Cable Length for
output) Lights up when output is ON OUT1: Green; OUT2: Red 1sec. or less Hysteresis mode: Variable (can be set from 0), Window comparator mode: 3-digit fixed Note 5) Status LED's Response time Hysteresis Power supply voltage 12 to 24VDC (ripple 10% or less) IP65 Operating: 0 to 50C, Stored: 25 to 85C (with no condensation and freezing) 1000VAC for 1 min. between external terminal and case 50M
output) Lights up when output is ON OUT1: Green; OUT2: Red 1sec. or less Hysteresis mode: Variable (can be set from 0), Window comparator mode: 3-digit fixed Note 5) Status LED's Response time Hysteresis Power supply voltage 12 to 24VDC (ripple 10% or less) IP65 Operating: 0 to 50C, Stored: 25 to 85C (with no condensation and freezing) 1000VAC for 1 min. between external terminal and case 50M
Make sure workpieces mounted on the table do not interfere with other workpieces or the facilities around the table. *3 Position after returning to origin *4 [ ] for when the direction of return to origin has changed Model L A B n D E Without lock With lock LEFS32Em-50m 332 384 56 180 4 LEFS32Em-100m 382 434 106 230 4 LEFS32Em-150m 432 484 156 280 4 LEFS32Em-200m 482 534 206 330 6
Size: 32, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 50mm, Motor Option: None, Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: 1P (LECP1, PNP, Programless Type), I/O
Size: 32, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 50mm, Motor Option: None, Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IPâ„¢ Direct Input
Size: 32, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 50mm, Motor Option: None, Rod End Thread: Male, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length
Size: 32, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 50mm, Motor Option: None, Rod End Thread: Male, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 5m, Controller Type - LEC, JXC: LECP1, PNP, Programless Type, I/O Cable Length for LEC: 1.5m
Example) D-Y59AL Impact resistance 1000m/S Insulation resistance 50M or more at 500VDC (between lead wire and case) Withstand voltage 1000VAC for 1min.
Auto Switch Common Specifications Type Reed switch Solid state switch 3 wire: 10A or less 2 wire: 1mA or less None Leakage current 1ms or less Note 3) 1.2ms Operating time 1000m/s {102G} 300m/s {30.6G} Impact resistance 50M or more with a 500VDC megohmmeter (between lead wire & case) Insulation resistance 1000VAC for 1 min.
consumption Withstand voltage Insulation resistance Noise resistance Vibration resistance Impact resistance Weight Enclosure Port size (Rc, NPT, G) 1s or less Note 3) Hysteresis mode: Variable (can be set from 0), Window comparator mode: Fixed (3 digits) 12 to 24VDC (ripple 10% or less) 160mA or less 170mA or less 150mA or less 1000VAC for 1 min. between external terminal block and case 50M