Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 500mm, Motor Option: W (with Lock/Motor Cover), Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: 6P (LECA6, PNP, Step Data Input Type),
Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 500mm, Motor Option: with Lock/Motor Cover, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 5m, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -,
Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 500mm, Motor Option: with Lock/Motor Cover, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 5m, Controller Type - LEC, JXC: LECA6, PNP, Step Data Input Type, I/O Cable Length for
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 500mm, Motor Option: W (with Lock/Motor Cover), Rod End Thread: Female, Mounting: F (Rod Flange), Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5m)
Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 500mm, Motor Option: with Lock/Motor Cover, Rod End Thread: Female, Mounting: Rod Flange, Actuator Cable: Standard Cable, Actuator Cable Length: 5m, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
13 20 Lead 16: LEY40A 0 0 0 300 400 500 200 100 600 0 300 400 500 200 100 600 Speed [mm/s] Speed [mm/s] 225 LEY Series Step Motor (Servo/24 VDC) Servo Motor (24 VDC) Refer to page 224 for the LECP6, LECP1, LECPMJ, and page 225 for the LECPA.
Cooling capacity: 220W; Heating capacity: 500W; Dimensions: 130mm x 150mm x 210mm; Temperature range setting: 10 to 60°C; Temperature stability: ±0.1°C; Power supply requirement: 24 VDC ±10%; Circulating fluid: Tap water or ethylene glycol solution (20% or less); Standards: CE, UKCA, UL (NRTL), RoHS
Cooling capacity: 220W; Heating capacity: 500W; Dimensions: 130mm x 150mm x 210mm; Temperature range setting: 10 to 60°C; Temperature stability: ±0.1°C; Power supply requirement: 24 VDC ±10%; Circulating fluid: Tap water or ethylene glycol solution (20% or less); Standards: CE, UKCA, UL (NRTL), RoHS
Cooling capacity: 220W; Heating capacity: 500W; Dimensions: 130mm x 150mm x 210mm; Temperature range setting: 10 to 60°C; Temperature stability: ±0.03°C or better depending on load stability; Power supply requirement: 24 VDC ±10%; Circulating fluid: Tap water or ethylene glycol solution (20% or less); Standards: CE, UL, RoHS
Protective device Three phase AC200/200-280V10% (50/60Hz) Power supply 500W x 765D x 1705H Dimensions (mm) Deposition of fluororesin film. Fluororesin film changed from conventional adhesive application to a unique deposition method, facilitating longer life and high temperature operation.
Size: 40, Motor Mounting Position: Top Mounting, Motor Type: Step Motor (Servo/24 VDC), Lead Screw: A (LEY16: 10mm; LEY25: 12mm; LEY32/40: 16mm), Stroke: 500mm, Motor Option: W (with Lock/Motor Cover), Rod End Thread: Female Rod End, Mounting: Ends Tapped (Standard), Actuator Cable Type: S (Standard Cable), Cable Length: 5 (5m), Controller/Driver Type: 1P (LECP1, PNP, Programless Type), I
Size: 40, Motor Mounting Position: Top Mounting, Motor Type: Step Motor (Servo/24 VDC), Lead Screw: LEY16: 10mm; LEY25: 12mm; LEY32/40: 16mm, Stroke: 500mm, Motor Option: with Lock/Motor Cover, Rod End Thread: Female Rod End, Mounting: Ends Tapped (Standard), Actuator Cable Type: Standard Cable, Cable Length: 5m, Controller/Driver Type: LECP1, PNP, Programless Type, I/O Cable Length: 5m,
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, ACTUATOR, ELECTRIC ACTUATOR, MC, 40MM LE ELECTRIC ACTUATOR
Size: 32, Motor Mounting Position: Top Mounting, Stroke: 500, Motor Option: w/o Option, Stroke Adjustment Unit: W (Both Sides)
Magnet: Built-in, Mounting: Axial Foot, Bore Size: 125mm, Stroke: 500mm, Rod Boot: Single Rod, Rod Type: Double Rod, Auto Switch: -, Lead Wire or Prewired Connector: -
Magnet: Built-in, Mounting: Basic, w/o Bracket, Bore Size: 125mm, Stroke: 500mm, Rod Boot: Single Rod, Rod Type: Double Rod, Auto Switch: -, Lead Wire or Prewired Connector: -
Magnet: Built-in, Mounting: Center Trunnion, Bore Size: 125mm, Stroke: 500mm, Rod Boot: Single Rod, Rod Type: Double Rod, Auto Switch: -, Lead Wire or Prewired Connector: -