Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 200mm, Motor Option: None, Rod End Thread: Female, Mounting: Double Clevis, Actuator Cable: Standard Cable, Actuator Cable Length: 5m, Controller Type - LEC, JXC: LECA6, PNP, Step Data Input Type, I/O Cable Length for LEC: 5m, Controller Mounting: DIN
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
Lead 8: LEY40B 27 40 20 30 Lead 16: LEY40A 13 20 Lead 16: LEY40A 0 0 0 300 400 500 200 100 600 0 300 400 500 200 100 600 Speed [mm/s] Speed [mm/s] 225 LEY Series Step Motor (Servo/24 VDC) Servo Motor (24 VDC) Refer to page 224 for the LECP6, LECP1, LECPMJ, and page 225 for the LECPA.
Size: 25, Motor Mounting: Top Mounting Type, Motor Type: S6 [AC Servo Motor, (Absolute Encoder), Output 100W], Lead: B [LEY25, 6mm; LEY32, 8(10)mm], Stroke: 200mm, Motor Option: w/o Option, Rod End: Rod End Female Thread, Mounting: Double Clevis, Actuator Cable Type: -, Cable Length: -, Controller Type: -, I/O Connector: -
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
JCM CYLINDER, JCM, ROUND BODY CYLINDER 875, 0.00000 lb
Magnet: Built-in Magnet, Mounting: Male Thread on Both Covers, Direct Mounting, Bore Size: 40mm, Port Thread: NPT1/8, Stroke: 200mm, Rod End Thread: Male Thread, Mounting Nut: w/Mounting Nut, 1 pc, Rod End Bracket: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: None, Mounting: Axial Foot, w/Mounting Bracket, Bore Size: 25mm, Port Thread: M5, Stroke: 200mm, Rod End Thread: Male Thread, Mounting Nut: w/Mounting Nut, 1 pc, Rod End Bracket: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: None, Mounting: Male Thread on Both Covers, Direct Mounting, Bore Size: 25mm, Port Thread: NPT1/8, Stroke: 200mm, Rod End Thread: Male Thread, Mounting Nut: w/Mounting Nut, 1 pc, Rod End Bracket: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
This is a legacy product, and replaced byNCQ8B150-200
Accuracy: Basic Type, Size: 32, Motor Mounting Position: R (Right Side Parallel), Motor Type: NY (Mounting Type Y), Lead Screw: A [LEY25, 12mm; LEY32, 16mm, (20); LEY63, 20mm], Stroke: 200mm, Dust/Drip Proof: Size 25, 32: w/o Enclosure; Size 63: IP5x, Dust Proof Specification, Rod End Thread: Rod End Female Thread, Mounting: D (Double Clevis)
Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 200mm, Motor Option: None, Rod End Thread: Female, Mounting: D (Double Clevis)
Size: 25, Motor Mounting Position: Top, Motor: A [Servo Motor (24 VDC)], Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 200mm, Motor Option: None, Rod End Thread: Female, Mounting: D (Double Clevis)
Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 200mm, Motor Option: None, Rod End Thread: Female, Mounting: D (Double Clevis)
Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 200mm, Motor Option: None, Rod End Thread: Female, Mounting: D (Double Clevis)
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Support bracket: With mounting nut (1 pc.), Port thread
Size: 32, Motor Mounting: L (Left Side Parallel Type), Motor Type: S3 [AC Servo Motor, (Incremental Encoder), Output 200W], Lead: B [LEY25, 6mm; LEY32, 8(10)mm], Stroke: 200mm, Motor Option: w/o Option, Rod End: Rod End Female Thread, Mounting: D (Double Clevis)
Accuracy: Basic, Motor Mounting Position: Top Mounting, Motor Type: T8 [AC Servo Motor, (Absolute Encoder), 400W], Lead: L (2.86mm), Stroke: 200mm, Dust/Drip Proof: IP5x (Dust Proof Specification), Motor Option: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: D (Double Clevis)
Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 200mm, Motor Option: None, Rod End Thread: Female, Mounting: D (Double Clevis)
Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 200mm, Motor Option: None, Rod End Thread: Female, Mounting: D (Double Clevis)