53 Horizontal work load [kg] 80 Vertical work load [kg] 40 Lead 4: LEY40C 60 Lead 8: LEY40B Lead 8: LEY40B 27 40 20 30 Lead 16: LEY40A 13 20 Lead 16: LEY40A 0 0 0 300 400 500 200 100 600 0 300 400 500 200 100 600 Speed [mm/s] Speed [mm/s] 225 LEY Series Step Motor (Servo/24 VDC) Servo Motor (24 VDC) Refer to page 224 for the LECP6, LECP1, LECPMJ, and page 225 for the LECPA.
Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 200mm, Motor Option: B (w/Lock), Rod End Thread: M (Male), Mounting: D (Double Clevis), Actuator Cable: S (Standard Cable), Actuator Cable Length: 1 (1.5m), Controller Type - LEC, JXC: C51 (JXC51, Parallel NPN, Step Data Input Type), I/O Cable Length
Setting of response delay time Set range is 0 to 250m sec. to Communication range (simple communication protocol) Setting and checking 23. Press the [SEL] key once. The set screen of communication range (simple communication protocol) is displayed on the digital display. PV SV 24.
Table 5.3-12 List of set values Set values Explanation Initial value (Default setting) Setting/checking are not available unless the serial protocol setting is simple communication protocol. to Setting of response delay time Set range is 0 to 250m sec. Communication range (simple communication protocol) Setting and checking 23. Press the [SEL] key once.
Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Step motor (24‑V DC servo), Step data (points): 64, Actuator/cable type: LEY40C-200, I/O cable length / communication plug(m): 1.5, Controller/driver mounting method: DIN rail mounting type
Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Step motor (24‑V DC servo), Step data (points): 64, Actuator/cable type: LEY40C-50, I/O cable length / communication plug(m): Without I/O cable, Controller/driver mounting method: Screw mounting type
Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 250mm, Motor Option: None, Rod End Thread: M (Male)
Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 250mm, Motor Option: None, Rod End Thread: Male, Mounting: -, Actuator Cable: -, Actuator Cable Length: -, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug Connector or I/O Cable Length for JXC: -
Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 250mm, Motor Option: None, Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 1 (1.5m), Controller Type - LEC, JXC: 6N (LECA6, NPN, Step Data Input Type), I/O Cable Length for
Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 250mm, Motor Option: None, Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: AP (LECPA, PNP, Pulse Input Type), I/O Cable Length for LEC
Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 250mm, Motor Option: None, Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 1 (1.5m), Controller Type - LEC, JXC: C51 (JXC51, Parallel NPN, Step Data Input Type), I/O Cable
Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 250mm, Motor Option: None, Rod End Thread: Male, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 1.5m, Controller Type - LEC, JXC: JXC51, Parallel NPN, Step Data Input Type, I/O Cable Length for LEC: Without
Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 250mm, Motor Option: None, Rod End Thread: Male, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 1.5m, Controller Type - LEC, JXC: LECA6, NPN, Step Data Input Type, I/O Cable Length for LEC: 1.5m, Controller
Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 250mm, Motor Option: None, Rod End Thread: Male, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: LECPA, PNP, Pulse Input Type, I/O Cable Length for LEC: 1.5m, Controller Mounting
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, ACTUATOR, ELECTRIC ACTUATOR, MC, 40MM LE ELECTRIC ACTUATOR, 9.13448 lb
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
Series: LEFS (Ball Screw Drive), Accuracy: Basic Type, Size: 32, Motor Mounting Position: In-line, Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32: 16mm, Size 40: 20mm), Stroke: 400mm, Motor Option: w/o Lock, Auto Switch Mounting Bracket: None, Grease Application: with, Positioning Pin Hole: Housing B, Bottom, Actuator Cable: S (Standard Cable), Actuator
Bearing Type: M (Sliding Bearing), Stroke: 500mm, Motor Option: None, Switch Rail Option: R (w/Magnet/Switch Rail), Actuator Cable Type: S (Standard Cable), Actuator Cable Length, m: 1 (1.5), Controller Type - LEC, JXC: C51 (JXC51, Parallel NPN, Step Data Input Type), I/O Cable Length for LEC: No Cable, Controller Mounting: 7 (Screw Mounting), Communication Plug Connector: 1 (1.5m)
Size: 25, Motor Mounting Position: Top Mounting, Stroke: 200, Motor Option: w/o Option, Stroke Adjustment Unit: None, Actuator Cable Type: S (Standard Cable), Actuator Cable Length: 1 (1.5m), Controller Type - LEC, JXC: C51 (JXC51, Parallel NPN, Step Data Input Type), I/O Cable Length for LEC: w/o Cable, Controller Mounting: 7 (Screw Mounting), Communication Plug Connector or I/O Cable Length