Size: 40, Motor Mounting: In-line Type, Motor Type: Step Motor, Servo/24 VDC, Lead: LEY25, 3; LEY32/40, 4, Stroke: 50mm, Motor: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped, Body Bottom Tapped, Actuator Cable Length: 1.5m, Controller Type (LEC, JXC): JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Screw Mounting,
6 (160.5) Cable length y 250 65 M4 x 0.7 thread depth 8 (F.G. terminal) 15 15 20 20 20 24 ( ) 3H9 depth 3 0.025 0 20 Lock cable (3.5) 24 n x 4.5 4 48 [mm] Model L 335.5 380.5 435.5 480.5 535.5 580.5 635.5 680.5 735.5 780.5 835.5 880.5 A B n D E 120 D x 120 (= E) B 10 LEFS25;-100 LEFS25;-100B LEFS25;-200 LEFS25;-200B LEFS25;-300 LEFS25;-300B LEFS25;-400 LEFS25;-400B LEFS25;-500 LEFS25;-500B
Example: LEFS16B-100B-R1C917 1 D T 7 C Compatible actuators Electric Actuator/Rod LEY Series Electric Actuator/Guide Rod LEYG Series Electric Actuator/Slider LEF Series Electric Slide Table LES/LESH Series Electric Rotary Table LER Series Electric Actuator/Guide Rod Slider LEL Series Electric Actuator/Miniature LEPY/LEPS Series Electric Gripper LEH Series Electric Actuator/Low-Profile Slider
Precautions for wiring and cables when handling the wiring and cables. 7 No.JXC-OMU0030-A 2.3 How to Order The part number construction for this product is as follows: Controller Electric actuator model Controller Example LEMB25T-500B-R12N1D Specify LEMB25UT-500 Compatible (Enter from the electric actuator part P Step motor (Servo DC24V) number LE to stroke / rotating angle) Number of step
Size: 40, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 500mm, Motor Option: B (w/Lock)
Size: 40, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 500mm, Motor Option: w/Lock, Rod End Thread: -, Mounting: -, Actuator Cable: -, Actuator Cable Length: -, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug Connector or I/O Cable Length for
Size: 40, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 500mm, Motor Option: B (w/Lock), Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IPâ„¢ Direct
Size: 40, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 500mm, Motor Option: B (w/Lock), Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IPâ„¢ Direct
Size: 40, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 500mm, Motor Option: w/Lock, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 5m, Controller Type - LEC, JXC: JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length
Size: 40, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 500mm, Motor Option: w/Lock, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 5m, Controller Type - LEC, JXC: JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length
New Products Guide 1 Directional Control Valves Actuators Vacuum Equipment CAT.E00-6A INDEX New Products Guide 1 Directional Control Valves 5 Port Solenoid Valve Fieldbus System (For Input/Output) 2/3 Port Mechanical Valve Series SY3000/5000/7000 Series EX600 Series VM100/200 P .6 P .264 P .322 Actuators Foot Pedal Type 5 Port Mechanical Valve XT34-60/67 Air Cylinder Air Cylinder Series CJ2
2Heat resistant -X7 Page 229 !3Both sides angle adjustable -X10 Page 229 !4One side angle adjustable, One side with cushion -X11 Page 230 !
Size: 25, Motor Mounting: D (In-line Type), Motor Type: Step Motor, Servo/24 VDC, Lead: C (LEY25, 3; LEY32/40, 4), Stroke: 150mm, Motor: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped, Body Bottom Tapped, Actuator Cable Length: 1.5m, Controller Type (LEC, JXC): C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type), I/O Cable Length for LEC: w/o Cable, Controller Mounting:
Size: 25, Motor Mounting: D (In-line Type), Motor Type: Step Motor, Servo/24 VDC, Lead: B (LEY25, 6; LEY32/40, 8), Stroke: 100mm, Motor: w/o Lock, Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: Ends Tapped, Body Bottom Tapped, Actuator Cable Length: 1.5m, Controller Type (LEC, JXC): C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type), I/O Cable Length for LEC: w/o Cable
Size: 25, Motor Mounting: D (In-line Type), Motor Type: Step Motor, Servo/24 VDC, Lead: A (LEY25, 12; LEY32/40, 16), Stroke: 350mm, Motor: w/o Lock, Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: F (Rod Flange), Actuator Cable Length: 1.5m, Controller Type (LEC, JXC): C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type), I/O Cable Length for LEC: w/o Cable, Controller
Size: 25, Motor Mounting: In-line Type, Motor Type: Step Motor, Servo/24 VDC, Lead: LEY25, 3; LEY32/40, 4, Stroke: 150mm, Motor: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped, Body Bottom Tapped, Actuator Cable Length: 1.5m, Controller Type (LEC, JXC): JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Screw Mounting
Size: 25, Motor Mounting: In-line Type, Motor Type: Step Motor, Servo/24 VDC, Lead: LEY25, 6; LEY32/40, 8, Stroke: 100mm, Motor: w/o Lock, Rod End Thread: Rod End Male Thread, 1 Rod End Nut Included, Mounting: Ends Tapped, Body Bottom Tapped, Actuator Cable Length: 1.5m, Controller Type (LEC, JXC): JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length for LEC: w/o Cable, Controller Mounting
Not applicable to 6. sign "X", "X7", "Z", "U" and "E4". Omron D2VW-01, gold plated contacts, 100 mA 30 V DC / 125 V AC. Temperature range: -40 to +85 C / -40 to +185 F. Not applicable to 6. sign "X", "X7", "Z", "U" and "E4". FOUNDATION fieldbus and Profibus Uo(Voc) = 5.0V, Io(Isc) = 17.8mA, Po = 22.2mW, Co(Ca) = 10nF, Lo(La) = 10H. K06 G Exhaust adapter.
-X7: Heat Resistant Type Please consult with SMC for further information on specifications, dimensions and delivery. 2 1 Shaft, Bolt, Parallel key Made of Stainless Steel Spec. Heat Resistant Type -X7 -X6 CRA1 Refer to How to Order on pages 11-7-2 and 24. X7 Refer to How to Order on pages 11-7-2, 13 and 18.
-X7: Heat Resistant Type Please consult with SMC for further information on specifications, dimensions and delivery. 2 1 Shaft, Bolt, Parallel key Made of Stainless Steel Spec. Heat Resistant Type -X7 -X6 CRA1 Refer to How to Order on pages 11-7-2 and 24. X7 Refer to How to Order on pages 11-7-2, 13 and 18.