Size: 16, Bearing Type: L (Ball Bushing Bearing), Motor Mounting Position: Top Mounting, Lead: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 200mm, Motor Option: W (w/Lock/Motor Cover), Guide Option: w/o Option, Actuator Cable Type, Length: R3 (3m), Controller: C91 (Ether Net/IPâ„¢), Mounting: 8 (DIN Rail)

Size: 16, Motor Mounting Position: Top Mounting, Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 150mm, Motor Option: C (w/Motor Cover), Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped/Body Bottom Tapped, Top Mounting & In-line, Actuator Cable Type, Length: R3 (3m), Controller: C91 (Ether Net/IPâ„¢), Mounting: 8 (DIN Rail)

Size: 16, Bearing Type: L ( Ball Bushing Bearing), Motor Mounting: D (In-line Type), Motor Type: Step Motor (Servo/24VDC), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 150mm, Motor Option: C (with Motor Cover), Guide Option: w/o Guide, Actuator Cable Type: R (Robotic Cable - Flexible cable), Actuator Cable Length: 3 (3m), Controller Type for (LEC, JXC): C91 (JXC91, EtherNet

Size: 16, Bearing Type: L (Ball Bushing Bearing), Motor Mounting Position: D3 (In-line; Motor Cover Direction: Top), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 150mm, Motor Option: C (w/Motor Cover), Guide Option: w/o Option, Actuator Cable Type, Length: R3 (3m), Controller: C91 (Ether Net/IPâ„¢), Mounting: 8 (DIN Rail)

Size: 25, Motor Mounting Position: In-line, Lead: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 150mm, Motor Option: w/Motor Cover, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped/Body Bottom Tapped, Top Mounting & In-line, Actuator Cable Type, Length: 3m, Controller: Ether Net/IPâ„¢, Mounting: DIN Rail, I/O Cable: -, Communication Plug Connector: -

Size: 25, Motor Mounting Position: D (In-line), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 150mm, Motor Option: C (w/Motor Cover), Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped/Body Bottom Tapped, Top Mounting & In-line, Actuator Cable Type, Length: R3 (3m), Controller: C91 (Ether Net/IPâ„¢), Mounting: 8 (DIN Rail)

Size: 16, Bearing Type: M (Sliding Bearing), Motor Mounting Position: D2 (In-line; Motor Cover Direction: Right), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 150mm, Motor Option: C (w/Motor Cover), Guide Option: w/o Option, Actuator Cable Type, Length: R3 (3m), Controller: C91 (Ether Net/IPâ„¢), Mounting: 8 (DIN Rail)

-XAl Change of rod end shape -XB6 Heat resistant cylinder (10 to 150C) * Not available with switch & with air cushion VMounted on the product. vPlease order separately.

(Option) Amplifier Heater (Option) Ambient temperature: Max. 150C (Sensor) 2-color indicator An optional heater is available. Auto switches are mountable from 4 directions.

Symbol Nil None A B C Changed part XVD Without indicator With indicator Without indicator With indicator XLF100-30-1 XLF100A-30-1 XLF100-30-1H XLF100A-30-1H 5 to 60C 8-1 8-2 XGT 8-1 5 to 150C 8-2 Temperature specifications Symbol Nil 5 to 60C 5 to 150C H0 CYV Temperature Seal material: Same as the seal materials of How to Order Valve Same as How to Order Specifications Valve type Shaft seal

) Symbol -XB6 2 Heat Resistant Cylinder (10 to 150C) Bore size Stroke How to Order Standard model no.

cylinder can create a gas that is hazardous to humans. 1729 C Made to Order Common Specifications: -XB6: Heat Resistant Cylinder (10 to 150C) Symbol -XB6 Heat Resistant Cylinder (10 to 150C) 2 CY3B series How to Order Temperature Range for Operating Cylinder and Piston Speed 1.

Residence time of water at 20C is 5.5 x 10-6 sec, whereas at 150C it is 2.8 x 10-8 sec, or 200 times shorter. As an example, it took 800 minutes to evacuate moist air from a 150mm x 500mm P/A test chamber to 10-9Torr. The same process took only 4 minutes with dry (20ppb) nitrogen.

Residence time of water at 20C is 5.5 x 10-6 sec, whereas at 150C it is 2.8 x 10-8 sec, or 200 times shorter. As an example, it took 800 minutes to evacuate moist air from a 150mm x 500mm SMC test chamber to 10-9Torr. The same process took only 4 minutes with dry (20ppb) nitrogen.

Symbol 1 Heat Resistant Cylinder (10 to 150C) -XB6 Air cylinder which changed the seal material and grease, so that it could be used even at higher temperature up to 150 from 10C.

(Except swivel elbow) Fluid temperature: 65 to 260C (Swivel elbow: 5 to 150C) Grease-free, Can be used with steam. Applicable tubing O.D.

-XAl Change of rod end shape -XB6 Heat resistant cylinder (10 to 150C) -XB7 Cold resistant cylinder (40 to 70C)*1 Mounting Brackets/Part No.

(Option) Amplifier Heater (Option) Ambient temperature: Max. 150C (Sensor) 2-color indicator An optional heater is available. Auto switches are mountable from 4 directions.

Bore size (mm) Effective thread length Width across flats A D H K MM W ZZ 40 50 63 80 100 32 37 37 37 47 18 22 22 26 31 35 40 40 40 50 20 25 25 30 36 58 71 71 72 85 7 11 11 11 15 M18 x 1.5 9 9 9 0 0 153 172 183 205 228 M22 x 1.5 M22 x 1.5 M26 x 1.5 A B M30 x 1.5 With heavy duty scraper -XC4 Heat resistant (150C) -XB6 4 2 The cylinder seals are changed to a heat resistance (to 150C) material