(mm) Color Symbol N R BU B Translucent Red (Translucent) Blue (Translucent) Black (Opaque) Inch nominal size Inch nominal size 5/32" 5/16" Operating Temperature: Max. 200C It varies depending on the operating pressure. Refer to the graph for the maximum operating pressure.
Features PFA Super PFA Modified PTFE FEP Material Chemical resistance 260C 260C 260C 200C Heat resistance Flexibility Ion elution Internal smoothness Air, Water, Inert gas Fluid Chemical liquids, Deionized water Chemical liquids, Deionized water 4 to 19 2 to 25 4 to 12 4 to 12 Tubing O.D.
Bending value (Reference) 20 Complies with FDA (Food and Drug Administration) 177-1550 Operating temperature Air, Inert gas: 20 to 200C, Water: 0 to 100C (No freezing) dissolution test.
Table symbols : Can be used Compatibility is indicated for fluid temperatures of 200C or less. Consult SMC regarding fluids other than the above. Consult SMC regarding operating conditions.
Up to 215psi @ 200C. NO Cold-Flow Loosening of Compression Nuts Unique locking mechanism and tapered mounting surfaces. Swept Flow Path No reduction in i.d., and high conductivity. High Side-Loading Trapezoidal thread and tubing strain relief coupled for high-resistance. Changing Tube Diameters Fast & Easy Within each body size, a range of tube sizes available.
Size: 32, Bearing Type: M (Sliding Bearing), Motor Mounting: Top Mounting Type, Motor Type: Step Motor (Servo/24VDC), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 200mm, Motor Option: C (with Motor Cover)
Size: 32, Bearing Type: Sliding Bearing, Motor Mounting: Top Mounting Type, Motor Type: Step Motor (Servo/24VDC), Lead: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 200mm, Motor Option: with Motor Cover, Guide Option: -, Actuator Cable Type: -, Actuator Cable Length: -, Controller Type for (LEC, JXC): -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug Connector
Applicable to TD TID Maximum operating temperature 200C chemical liquids such as acid, alkali and deionized water. As the tube runs through the fitting itself, a setting is available for any optional position. TH TIH Taper thread Thread type: R, NPT Body Material: New PFA Collet The tube is held securely in place by the tightening nut and collet.
FEP Tubing (Fluoropolymer) Heat resistance:200C It changes according to the operating pressure.
Fluoropolymer Fittings Hyper Fitting/Flare type Series LQ3 Specifications LQ310 LQ320 LQ330 Model Material Max. operating pressure (at 20C) New PFA 1.0 MPa 0 to 150C 0 to 200C 3 to 25 1/8" to 1 1/4" Nut material: PVDF Operating temperature Nut material: PFA Metric Inch Applicable tube size Refer to Best Pneumatics No. 7 for further details.
Nut Tubing support Insert bushing Tubing Before tightening Seal locations Excellent heat resistance The use of a nut with locking mechanism and trapezoidal screw threads maximizes seal performance even when subjected to heat cycles, maintaining integrity up to 200C.
Size: 32, Bearing Type: M (Sliding Bearing), Motor Mounting: Top Mounting Type, Motor Type: Step Motor (Servo/24VDC), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 200mm, Motor Option: w/o Option, Guide Option: w/o Guide, Actuator Cable Type: R (Robotic Cable - Flexible cable), Actuator Cable Length: 3 (3m), Controller Type for (LEC, JXC): 6P (LECA6, Step Data Input Type
Size: 32, Bearing Type: M (Sliding Bearing), Motor Mounting: Top Mounting Type, Motor Type: Step Motor (Servo/24VDC), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 200mm, Motor Option: B (with Lock), Guide Option: w/o Guide, Actuator Cable Type: R (Robotic Cable - Flexible cable), Actuator Cable Length: 3 (3m), Controller Type for (LEC, JXC): 6P (LECA6, Step Data Input
Size: 32, Bearing Type: M (Sliding Bearing), Motor Mounting: Top Mounting Type, Motor Type: Step Motor (Servo/24VDC), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 300mm, Motor Option: w/o Option, Guide Option: w/o Guide, Actuator Cable Type: R (Robotic Cable - Flexible cable), Actuator Cable Length: 3 (3m), Controller Type for (LEC, JXC): 6P (LECA6, Step Data Input Type
Size: 32, Bearing Type: M (Sliding Bearing), Motor Mounting: Top Mounting Type, Motor Type: Step Motor (Servo/24VDC), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 30mm, Motor Option: w/o Option, Guide Option: w/o Guide, Actuator Cable Type: R (Robotic Cable - Flexible cable), Actuator Cable Length: 3 (3m), Controller Type for (LEC, JXC): 6P (LECA6, Step Data Input Type
Size: 32, Bearing Type: Sliding Bearing, Motor Mounting: Top Mounting Type, Motor Type: Step Motor (Servo/24VDC), Lead: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 200mm, Motor Option: with Lock, Guide Option: w/o Guide, Actuator Cable Type: Robotic Cable - Flexible cable, Actuator Cable Length: 3m, Controller Type for (LEC, JXC): w/Controller, PNP, I/O Cable Length for LEC: 3m