Valve Type: 23 (3-port, N.C. on one side, N.O. on none side), Voltage: 5 (24VDC), Electrical Entry: K (Plug Connector, 300mm), Light: Z (with Light), Tubing Size: 4 (OD x ID: ø4 x ø2; Length: 100mm)
Valve Type: 23 (3-port, N.C. on one side, N.O. on none side), Voltage: 5 (24VDC), Electrical Entry: KO (Plug Connector, w/o Connector), Light: Z (with Light), Tubing Size: 4 (OD x ID: ø4 x ø2; Length: 100mm)
Note 2) For 10-V124(A) How to Order Valve Manifold Assembly Ordering example Stations 5 4 3 2 1 Valve (N.C.) 10-V114-5GZ 2 1 3 2 Blanking plate assembly V100-77-1A Manifold base (5 stations) 10-VV100-S41-05-M5 10-VV100-S41-05-M51 set (S41 type 5 station manifold part no.)
/ T5/T6 Ex ia IIC T4/T5/T6 Ga Class I, Zone 0 AEx ia IIC T4/T5/T6 Ga Ui 24 V, Ii 380 mA, Pi 5.32 W, Ci 5 nF, Li 10 H.
T2 = [s] L 0.5 V (T1 + T3) V Duty ratio: Ratio of T to T6 T T6 x 100 T = T1 + T2 + T3 + T4 T4 varies depending on the motor type and load. The value below is recommended. = 0.1 + 0.90 + 0.1 + 0.05 = 1.15 [s] 1000 5000 mm/s2 T4 = 0.05 [s] 800 10 mm/s2 Step 3 Check the allowable moment.
kg] 0 10 20 30 40 50 60 Work load [kg] 1500 1500 1500 Mep 1000 1000 1000 L3 [mm] L3 [mm] L3 [mm] m L3 Z 500 500 500 0 0 0 0 10 20 30 40 50 60 Work load [kg] 0 5 10 15 20 Work load [kg] 0 10 20 30 40 Work load [kg] 1500 1500 1500 L4 1000 1000 1000 L4 [mm] L4 [mm] L4 [mm] X 500 500 500 0 0 0 0 5 10 15 20 Work load [kg] 0 10 20 30 40 Work load [kg] 0 10 20 30 40 50 60 Work load [kg] 1500 1500
X 500 500 500 500 0 0 0 0 10 20 30 40 50 0 0 2 4 6 8 10 12 14 0 5 10 15 20 25 30 0 10 20 30 40 50 60 Work load [kg] Work load [kg] Work load [kg] Work load [kg] 2000 2000 2000 2000 Mey 1500 1500 1500 1500 L5 [mm] L5 [mm] L5 [mm] L5 [mm] m 1000 1000 1000 1000 Wall L5 Y 500 500 500 500 0 0 0 0 10 20 30 40 50 0 0 2 4 6 8 10 12 14 0 5 10 15 20 25 30 0 10 20 30 40 50 60 Work load [kg] Work load
5 10 15 20 Work load [kg] 0 10 20 30 40 Work load [kg] 0 10 20 30 40 50 60 Work load [kg] 11LEFS 1500 1500 1500 Mep 11LEJS 1000 1000 1000 L3 [mm] L3 [mm] L3 [mm] m 25AL3 Z 500 500 500 LEC 0 0 0 0 5 10 15 20 Work load [kg] 0 10 20 30 40 Work load [kg] 0 10 20 30 40 50 60 Work load [kg] LEC S 1500 1500 1500 LEC SS-T LEC Y LEC Y L4 1000 1000 1000 L4 [mm] L4 [mm] L4 [mm] X Motorless 500 500
1.0 M3 x 8 0.63 M4 x 10 1.5 8 7.5 19 M4 x 0.7 7.5 46 30 3.7 11 42 NY M2.5 x 10 1.0 M3 x 8 0.63 M4 x 10 1.5 8 7.5 19 M3 x 0.5 5.5 45 30 5 11 38 NX M2.5 x 10 1.0 M3 x 8 0.63 M4 x 10 1.5 8 4.5 19 M4 x 0.7 7.5 46 30 3.7 11 42 NM1 M3 x 5 0.63 M3 x 8 0.63 M4 x 10 1.5 5 11.8 19 3.4 7.0 31 28 3.5 8.5 42 NM2 M2.5 x 10 1.0 M3 x 8 0.63 M4 x 10 1.5 6 48 19 3.4 7.0 31 28 3.5 8.5 42 25 NZ M3 x 12 1.5
9/16 21/32 21/32 11/32 11/32 9/32 9/32 10-FB3 10-FB2 10-FB4 10-FB1 10-FLB1 (Short) 10-FLB2 10-FLB2 (Short) 10-FLB1 21 Page 5 Distributed by Power Aire, Inc.
Calculation example) T1 to T4 can be calculated as follows. L Speed: V [mm/s] a1 a2 T1 = V/a1 = 300/10 = 0.03 [s], T3 = V/a2 = 300/10 = 0.03 [s] Time T = T1 + T2 + T3 + T4 [s] [s] L 0.5 V (T1 + T3) V T1: Acceleration time and T3: Deceleration time can be found by the following equation.
ISO Class 6 upper limit ISO Class 6 upper limit 10 10 LEJ LEL 10 10 Suction flow rate: 0 L/min Particle concentration [particles/m3] Particle concentration [particles/m3] LEM ISO Class 5 upper limit Suction flow rate: 0 L/min LEY 10 10 LES ISO Class 5 upper limit Suction flow rate: 10 L/min LEPY LEPS 1000 1000 Suction flow rate: 20 L/min LER ISO Class 4 upper limit ISO Class 4 upper limit
type LEPY Series Page 374 25 to 50 6.0 1.5 200 5 24 to 40 4.0 1.5 200 10 12.5 to 25 3.0 1.0 350 10 12 to 20 2.0 1.0 350 14 to 20 1.0 0.5 150 4 6 Slide table type LEPS Series 7 to 10 0.75 0.25 300 8 25 50 Page 383 25 to 50 2.0 1.5 200 5 24 to 40 2.0 1.5 200 10 12.5 to 25 1.5 1.0 350 10 12 to 20 1.5 1.0 350 370 LEPY/LEPS Series Mounting Variations Mounting from various directions Side mounting
Valve Type: 21 (N.C.), Voltage: 5 (24VDC), Electrical Entry: G (Grommet, 300mm), Light: Z (with Light), Tubing Size: 4 (OD x ID: ø4 x ø2; Length: 100mm), Lead Wire Length: 10 (1000mm)
Valve Type: 23 (3-port, N.C. on one side, N.O. on none side), Voltage: 6 (12VDC), Electrical Entry: G (Grommet, 300mm), Light: Z (with Light), Tubing Size: 4 (OD x ID: ø4 x ø2; Length: 100mm), Lead Wire Length: 6 (600mm)
mm] L1 [mm] L1 [mm] m X 100 100 100 100 0 0 2 4 6 8 10 0 0 2 4 6 8 10 0 0 2 4 6 8 10 0 0 2 4 6 8 10 Work load [kg] Work load [kg] Work load [kg] Work load [kg] Horizontal/Bottom mounting 300 300 300 300 L2 200 200 200 200 L2 [mm] L2 [mm] L2 [mm] L2 [mm] m Y 100 100 100 100 0 0 2 4 6 8 10 0 0 2 4 6 8 10 0 0 2 4 6 8 10 0 0 2 4 6 8 10 Work load [kg] Work load [kg] Work load [kg] Work load [kg
10 ISO Class 8 10 10 0 L/min (ANR) ISO Class 7 ISO Class 7 10 10 Particle concentration [particles/m3] Particle concentration [particles/m3] ISO Class 6 ISO Class 6 10 10 0 L/min (ANR) 50 L/min (ANR) ISO Class 5 ISO Class 5 10 10 1000 1000 20 L/min (ANR) ISO Class 4 ISO Class 4 100 100 70 L/min (ANR) 30 L/min (ANR) 10 10 1 1 0 0.1 0.2 0.3 0.4 0.5 0.6 0 0.1 0.2 0.3 0.4 0.5 0.6 Particle diameter
15 0 5 10 15 20 25 0 5 10 15 20 Vertical L7 Work load [kg] Work load [kg] Work load [kg] 1000 1000 1000 800 800 800 600 600 600 Z 400 400 400 200 200 200 Mep m 0 0 0 0 5 10 15 0 5 10 15 20 25 0 5 10 15 20 L8 Work load [kg] Work load [kg] Work load [kg] Calculation of Guide Load Factor Mounting orientation 1.
If unit is to be used in a washdown application, avoid directing fluid into the exhaust port. 10 Accessories Spacer Dimensions mm Epoxy Coated Aluminum, Stainless Screws, NBR Seals Model A Y20-T4 Y30-T4 Y40-T4 10 11 14 F.R.L. center Interface With T Bracket Interface with T-type bracket T-type bracket Epoxy Coated Aluminum, Stainless Screws, NBR Seals G F.R.L.