SMC Corporation of America
Elite Part Number Search
Search Results "LVM09R1-5A-KZ-Q"

A Valve q: SY3000-23-24A w: SY5000-221-1A e: SY7000-221-1A SUP stop valve spacer assembly with residual pressure release valve q: SY3000-222-1A w: SY5000-222-1A e: SY7000-222-1A B A B Double check spacer assembly with residual pressure release valve q: SY30M-56-5A w: SY50M-56-5A e: SY70M-56-5A SY30M-56-5A (2 pcs.)

0 t t r i w e r i u w y e q Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com q VQ7-8-FG-DVQ7-8-FG-D-R !0 !0 t t r i w y e q r i w e q VQ7-8-D-R FHG FJG FIG VQ7-8-DFHG FJG FIG !0 !0 t t r i w y e q r i w e q VQ7-8-FPG-D!

Includes bushing assembly (SY3000-52-5A) 3 pcs. 1 SY360--(-Q) Valve P, R port (1: One-touch fitting for 8, 2: One-touch fitting for 5/16") Includes bushing assembly (SY3000-52-5A) 3 pcs. 1 2 2 SUP/EXH block assembly SY3000-55A(-Q) 3 End block assembly SY3000-56-1A(-Q) For D side (Bushing assembly: Not available for SY3000-52-5A) 4 End block assembly SY3000-56-1B(-Q) For U side (Bushing assembly

VQ 5 0 0 5 1 1 Terminal block box kit CE-compliant Type of actuation Nil Q CE-compliant VV5Q51-0603TU(-Q)1 setManifold base part no. *VQ5100-51(-Q)2 setsValve part no. (Stations 1 and 2) *VQ5200-51(-Q)2 setsValve part no. (Stations 3 and 4) *VQ5300-51(-Q)1 setValve part no.

): SQ1241 Double (latching): SQ1240 t e q w t e q w SQ1241 SQ1240 (A)(B) (A)(B) 4 2 4 2 5 1 3 5 1 3 (R1) (P)(R2) (R1)(P)(R2) Double (double solenoid): SQ1241D Double (double solenoid): SQ1240D y e e q w y e q w e SQ1240D SQ1241D (A)(B) (A)(B) 4 2 4 2 5 1 3 u 5 1 3 u (R1)(P)(R2) (R1)(P)(R2) 3 position: SQ1 41 3 4 5 3 position: SQ1 40 3 4 5 y e e q y w e e q w u u SQ1540 SQ1440 SQ1340 SQ1541

e r w q e r w 5 (EA) 4 (A) 3 (EB) 2 (B) 1 (P) 2-position single 2-position double (A)4 2(B) (A)4 2(B) 3(EB) (EA)5 1 3(EB) (EA)5 1 (P) (P) 4-position dual 3-port valve 3-position closed center/exhaust center/pressure center q e r w q e r w 3-position closed center 3-position exhaust center 4-position dual 3-port valve N.C. valve x 2 pcs.

How to Find the Flow Rate (at air temperature of 20C) Subsonic flow when P1 + 0.1013 < 1.89 (P2 + 0.1013) Q = 226S P(P2 + 0.1013) Sonic flow when P1 +0.1013 1.89 (P2 + 0.1013) Q = 113S (P1 + 0.1013) Q : Air flow rate [l/min (ANR)] S : Effective area (mm) P : Pressure drop (P1 P2) [MPa] P1: Upstream pressure [MPa] P2: Downstream pressure [MPa] Correction for different air temperatures Multiply

4 y q r e i !2 o !0 5A 2A 2B 2C 2D CJ1 CJP Y Front nose in line port N Basic style integrated clevis E Double end F Front nose u !

w q t VSR8-2-FG-DVSS8-2-FG-De r e r w q t w q t VSS8-2-DFHG FIG FJG VSR8-2-DFHG FIG FJG e r e r w q t w q t VSR8-2-DFDAG FDBG FDCG e r w q t Replacement Parts VSR8-2-DFDAG FDBG FDCG VSR8-2-DFHG FIG FJG VSR8-2-FG-DVSR8-2-FG-SVSS8-2-DFHG FIG FJG VSS8-2-FG-DVSS8-2-FG-SDescription No.

w e q w VQC1100 VQC1101 2(B) (A)4 2(B) (A)4 r r (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) e q w e w q VQC1201 VQC1200 2(B) (A)4 2(B) (A)4 (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) r r e q w e q w VQC1300 VQC1400 VQC1301 VQC1401 2(B) (A)4 2(B) (A)4 2(B) (A)4 2(B) (A)4 (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) VQC1500 VQC1501 r r 2(B) (A)4 2(B) (A)4 (R1)5 1 (P) 3(R2) (R1)5

ZS-20-A 16 NPN Open Collector 2 output w/o analog output, 3 revolution adjustment ISl IWith lead wire ZS-20-5A 17 NPN Open Collector 2 output w/o analog output, 200 revolution adjustment Note) When ordering switch with 5m long lead wire, indicate both part numbers. Ex.) ZSE1-01-15CN1 pc. ZS-20-5A-501 pc.

In the case of liquid: P Q = 1.9 x 106Av (9) G Q : Flow rate [l/min] Av : Flow coefficient [m2] P : Pressure difference [MPa] G : Relative density [water = 1] In the case of saturated aqueous vapor: Q = 8.3 x 106Av P(P2 + 0.1) (10) Q : Flow rate [m3/s] Av : Flow coefficient [m2] P : Pressure difference [Pa] P1 : Relative density [MPa]: P = P1 P2 P2 : Relative density [MPa] Front matter 4

Use a circuit breaker having a sensitivity current of 30mA or less and a rated current of 5A.

How to Find the Flow Rate (at air temperature of 20C) Subsonic flow when P1 + 0.1013 < 1.89 (P2 + 0.1013) Q = 226S P(P2 + 0.1013) Sonic flow when P1 + 0.1013 1.89 (P2 + 0.1013) Q = 113S (P1 + 0.1013) Q: Air flow rate [l/min (ANR)] S: Effective area [mm] P: Pressure drop rate (P1P2) [MPa] P1: Upstream pressure [MPa] P2: Downstream pressure [MPa] Correction for different air temperatures

(arrangement as seen from lead wire side) 2-M2.6 x 0.45 D-sub Connector Cable Assembly Terminal No. q !5 !4 @4 !3 !2 @3 @2 !1 !0 o i !6 !7 w e r !8 Lead wire color Dot marking Terminal no. @1 @6 @5 Black None q !9 Brown None w y t @0 u Red None e Orange None r Yellow None t Pink None y Circular Connector Cable Assembly Terminal No.