Your search for LVM returned 30 result(s)
There were no hits with the full part number, but there were 2 hits in the keyword search.
There were no hits with the full part number, but there were 2 hits in the keyword search.
Product Information » New Products Search Results
Symbol: Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket, Lead Wire Length: 600mm, CE Compliant: CE Compliant
Symbol: 10R1 (Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 1 (Bracket), Lead Wire Length: 6 (600mm), CE Compliant: Q (CE Compliant)
Series LVM is a compact, direct acting, 2/3 port solenoid valve for chemicals. The unique construction reduces residual liquid to a minimum. Superior resistance to chemicals requires less maintenance. Service life (based on SMC test conditions) is 10 million cycles or more.Orifice diameter of LVM11: 1.5mm, Orifice diameter of LVM10: 1.4mm , Available with power-saving circuit , 2 port N.C
5/16-24 2 1/2 0.3 1.26 1.06 1 3/8 2.09 2.40 6 9/16 1 3/8 2 11/16 1 3 5/8 6 6 1 3/4 3/8 1/8 3/4-16 9/16 1/2 7/8 3/8 1 1/8 1 5/8 1 1/8 5/16-24 3 1 3/8 6 11/16 250 (2.5) 3.1 1.5 0 1.3 1.06 2.13 2.48 1 3 1/8 3 3/4 3/8 1 6 1/8 6 1/8 2 1/4 3/8 1/8 3/4-16 9/16 1/2 7/8 3/8 1 5/8 115/16 1 1/2 1 1/4 3/8-24 3 3/4 1 5/8 7 7/8 325 (3.25) 3.9 2 0 1.57 1.18 2.59 2.72 1 3/8 3 13/16 4 1/4 1/2 1 1/4 7 3/8
4 3 3/8 5 3/4 6 1 8 1 1/2 9 2 02 1/4 03 3/8 04 1/2 06 3/4 10 1 14 1 1/2 20 2 T H R E A D T H R E A D 1 Male 2 Female (Only NAMC220, 320, 520 Special Order Only) R(PT)* Remove (N) when ordering N NPT Courtesy of Steven Engineering, Inc. !
(K) (Y) 5 6 5 6 5 6 u 4 For single VQ110LJ2-1 Negative COM: VQ110NJ2-1 5 For double (latching) SQ1C41 SQ1B41 SQ1A41 4 2 4 2 4 2 For double (double solenoid) on A side (K) (Y) 5 6 6 VQ110 (N)J3(B)-1 For 3P, dual 3 port on A side N.C. N.C. N.O. N.O. 1 5 3 1 5 3 N.O.
5 4 3 2 1 8 7 6 5 4 3 2 1 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 Station 1 Station 1 Station 1 Station 2 Station 2 Station 2 Station 3 Station 3 Station 3 Station 4 Station 4 Station 4 COM. (+) 9 () () Station 5 Station 5 COM. (+) 10 (+) (+) (+) (+) (+) (+) (+) (+) Positive common Negative common Station 6 Station 6 Station 7 Station 7 Station 8 Station 8 * When using a valve with no polarity
Local Area: (800) 258-9200-www.stevenengineering.com VZS VFS G 1/2 VS4 VQ7 EVS VFN 5-3/8, 1/2 (3/4, 1) ( ): Rc 3/4, 1 Conduit terminal: VP4150-TDIN terminal: VP4150-DG 1/2 Applicable cable O.D. 6 to 12 G 1/2 ( ): Rc 3/4, 1 ( ): Rc 3/4, 1 3-6-5 6 Series VP450/470 Dimensions: VP4250/4350/4450 Grommet: VP4250-G-, VP4350-GVP4450-GBottom ported 5-3/8, 1/2 (3/4, 1) Manual override 4-9 mounting
(FD) D side Filter regulator SMC AP: Auto-drain (INA-13-854DG) Blanking plate (MP3-1) 212.5 (191: MP) MP: Manual drain (INA-13-854G) Plate assembly (VVQ4000 60A-1) 106 17 Drain port 6 AP: 10 MP: 6 Rc 1/2 (Supply port: Po) 4-Rc 1/2 17.5 42 70.5 119 " 185 5(R1), 3(R2) port P0 SMC R2 R1 5 1 P 3 30 PE 18 18 2-Rc 1/8 (Pilot EXH port) 70 (91) 29 38 163 L n Dimensions Formula L1 = 25n + 63, L2
(Stations 1 to 4) VQ1230-5B-C64 sets Valve part no.
C76 1 1 1 1 1 1 2 1 1 2 1 2 1 2 1 q y u i o !0 !1 !2 !3 (Switch type only) 2C C85 2D (2 for switch type) e r C95 5A CP95 (Switch type piston) 5B Nickel plating NCM C85RA B20/25 NCA D!6 i y !4 u q r e !1 t !5 !3 !0 !2 o 2C 2D !
AXT100-FC26-1 1.5 m AXT100-FC20-1 AXT100-FC10-1 AXT100-FC26-2 3 m AXT100-FC20-2 AXT100-FC10-2 AXT100-FC26-3 5 m AXT100-FC20-3 AXT100-FC10-3 Specified Layout COM. COM. 25 26 23 24 COM. COM. 21 22 19 20 19 20 19 20 17 18 17 18 17 18 15 16 15 16 15 16 COM. COM. 13 14 13 14 13 14 11 12 11 12 11 12 9 10 9 10 9 10 9 10 7 8 7 8 7 8 7 8 5 6 5 6 5 6 5 6 3 4 3 4 3 4 3 4 1 2 1 2 1 2 1 2 COM. COM.
VF KQ2P-04 KQ2P-06 KQ2P-08 KQ2P-10 KQ2P-03 KQ2P-07 KQ2P-09 KQ2P-11 4 6 8 10 5/32" 1/4" 5/16" 3/8" 16 18 20.5 22 16 18 20.5 22 32 35 39 43 32 35 39 43 6 8 10 12 6 8.5 10 11.5 VP4 VQ 1/2 VQ 4/5 Port plug VVQ1000-58A VQC 1/2 VQC 1/2 The plug is used to block the cylinder port.
Connector wiring diagram (mixed wiring) Connector type manifold 6 A 4 A 3 A 1 A 5 B 2 B Output 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing
Connector wiring diagram (mixed wiring) Connector type manifold 6 A 4 A 3 A 1 A 5 B 2 B Output 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing