Your search for LVM returned 30 result(s)
There were no hits with the full part number, but there were 2 hits in the keyword search.
There were no hits with the full part number, but there were 2 hits in the keyword search.
Product Information » New Products Search Results
size 25 (1B) 40 (1 1/2B) 50 (2B) 65 (2 1/2B) 80 (3B) 100 (4B) 150 (6B) 10 14 20 24 30 40 60 Note) The connection method is JIS 10KFF flange connection.
x 0.8 12 10 12 10 1 (P) 3 (R) 1 (P) XT34 Poppet VM200 2 port 3 port (A) 2 (A) 2 Side ported 1/4 Page 337 12 12 10 10 1 (P) 3 (R) 1 (P) VM400 3 port (OUT) 2 3 10 12 1 (N.C.)
(Including r and t) Manifold Block Assembly SQ Replacement Parts VFS VVQ5000 1 No. Part no. Description Material Q'ty VFR VVQ5000-80A-1 Gasket HNBR 10 Type VVQ5000-80A-2 Gasket HNBR 10 Option VQ7 A For 1 station Note) Spare parts consist of sets containing 10 pcs. each.
MXQA-A2087 47 4.4 17 6 10 36 11.2 16.2 M12 x 1 M6 x 12 MXQ25(A) MXQA-CS25 MXQA-CT25 MXQA-A2587 54 5.5 19 6 11 44 13.5 19.3 M14 x 1.5 M8 x 16 MXQ8B MXQB-CS8 MXQB-CT8 MXQB-A887 35 2 10 4 6.5 24 7.1 10.4 M8 x 1 M4 x 8 6.8 MXQ12B MXQB-CS12 MXQB-CT12 MXQB-A1287 40 2.8 12 5 8 29.4 9.2 12.6 M10 x 1 M5 x 10 8.8 MXQ16B MXQB-CS16 MXQB-CT16 MXQB-A1687 47 3.6 17 6 10 36 11.2 16.2 M12 x 1 M6 x
Connection thread Metric 2, 3.2, 4, 6, 8 M3 x 0.5, M5 x 0.8, M6 x 1.0 Metric 3.2, 4, 6, 8, 10, 12, 16 M5 x 0.8 R, Rc, G1/8, 1/4, 3/8, 1/2 10, 12, 16 R, Rc1/8, 1/4, 3/8, 1/2 Inch 1/8", 5/32", 1/4", 5/16" 3/8", 1/2" 10-32UNF NPT1/8, 1/4, 3/8, 1/2 1/8", 5/32", 3/16", 1/4" 10-32UNF 5/16", 3/8", 1/2" NPT1/16, 1/8, 1/4, 3/8, 1/2 Inch 1/8", 3/16", 1/4" 5/16", 3/8", 1/2" M5 x 0.8 R, Rc1/8, 1/4, 3
COM. 13 14 13 14 11 12 11 12 9 10 9 10 9 10 7 8 7 8 7 8 5 6 5 6 5 6 3 4 3 4 3 4 1 2 1 2 1 2 (P, PC: 26 pins) (PG, PGC: 20 pins) (PH, PHC: 10 pins) A mixture of single and double wiring can be specified on the manifold specification sheet. The maximum number of stations is determined according to the number of solenoids.
110 110 130 180 Q 26 28 28 34 34 50 50 60 76 R 4.5 5 5 5 5 9 9 10 12 S 1.6 2.0 2.0 2.3 2.3 3.2 3.2 4.5 4.5 5.5 6 6 7 7 9 9 9 11 159 172 178 204 210 225 232 259 311 13 13 16 16 19 19 22 22 32 100 113 119 145 151 166 173 200 253 63 76 76 90 90 106 106 122 160 20 20 20 20 20 20 20 20 20 63 76 76 90 90 106 106 122 160 10 10 10 10 10 10 10 10 10 1 8 1 4 3 8 AMG150 , , 1 4 3 8 , AMG250 1 2 3 8
Light load Motor load Voltage IFW510 1 to 10 20 1 or less N.C.
COM COM 1A 2A 3A 4A 5A 6A 7A 8A 9A 10A COM 25 26 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B COM COM 1 2 3 4 5 6 7 8 9 10 11 12 13 23 24 14 15 16 17 18 19 20 21 22 23 24 25 21 22 19 20 19 20 19 20 17 18 17 18 17 18 15 16 15 16 15 16 13 14 13 14 13 14 11 12 11 12 11 12 9 10 9 10 9 10 7 8 7 8 7 8 5 6 5 6 5 6 3 4 3 4 3 4 COM 1 2 1 2 1 2 COM COM T kit Terminal block (SQ2000 only) J kit Flat ribbon cable connector
thread Rc 1/4: Rc 1/4 thread 2 4 VQZ B A B A 7 SMC SMC SMC SMC SMC SMC B A 2 4 B A B A 6 B A VQD 2 4 B A B A 5 D side B A 6.5 L1 2 4 B A B A 4 B A 2 4 Manual override B A B A 3 B A 4 2 B A A 2 A 4 2 B A A 1 SMC Indicator light A 2 4 R4.5 Stations 12 X 16.5 (External pilot port) Rc 1/8 9 9 106 10 163 43.5 96.5 1(P), 5(R1), 3(R2) port 3-Rc 1/2 SMC (Pilot EXH port) Rc 1/8 1 P 5 3 R2 R1 42 17.5
Purchasing order is available in units of 10 pieces. VF KQ2P-04 KQ2P-06 KQ2P-08 KQ2P-10 KQ2P-03 KQ2P-07 KQ2P-09 KQ2P-11 4 6 8 10 5/32" 1/4" 5/16" 3/8" 16 18 20.5 22 16 18 20.5 22 32 35 39 43 32 35 39 43 6 8 10 12 6 8.5 10 11.5 VP4 VQ 1/2 VQ 4/5 Port plug VVQ1000-58A VQC 1/2 VQC 1/2 The plug is used to block the cylinder port.
Connector wiring diagram (mixed wiring) Connector type manifold 6 A 4 A 3 A 1 A 5 B 2 B Output 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing
102 1.0197 X 102 9.8692 X 103 1.0197 X 102 1 7.5006 1 X 106 1 X 103 1.0197 X 105 7.5006 X 103 1.4503 X 102 1 1 X 10 1.0197 X 10 9.8692 1 X 105 1 X 102 1 X 101 9.8692 X 101 1.0197 X 104 7.5006 X 102 1 1.0197 1.4503 X 10 9.8067 X 104 9.8067 X 102 9.8067 X 101 9.6784 X 101 1 X 104 7.3556 X 102 1 1.4217 X 10 9.8067 X 10 1.0133 X 105 1.0133 X 102 1.0133 X 101 1.0332 X 104 7.6000 X 102 1.0332 1.4706
Connector wiring diagram (mixed wiring) Connector type manifold 6 A 4 A 3 A 1 A 5 B 2 B Output 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing
Single wiring 5 6 7 8 9 10 19 20 19 20 19 20 19 20 19 20 19 20 19 20 19 20 1 2 3 4 5 6 7 8 9 10 1 2 3 4 NEW CONCEPT N.C. valve N.C. valve N.C. valve N.O. valve N.O. valve N.O. valve 5 6 7 8 9 10 1 2 3 4 R2 B R1 A P IP65 enclosure compliant kit (Lead wire) M 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 5 (R1) 3 (R2) 5 (R1) 3 (R2) 5 (R1) 3 (R2) 1 2 3 4 4 (A) 2 (B) 4 (A) 2 (B) 4 (A
: Serial transmission L Kit: Lead wire F, L, M and P kits 1 to 12 stations M Kit: Multiple connector C8 (For 8) C10 (For 10) T kit 1 to 10 stations 4150 S kit (without unit) Solenoid weight is not included.