SMC Corporation of America
Elite Part Number Search
Search Results "MDBF32-500Z-A93L"

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches

Magnet: D (Built-in Magnet), Mounting: F (Rod Flange), Bore: 32mm, Port Thread: Rc, Stroke: 500mm, Cushion: Rod Boot None; Air Cushion on Both Sides, Pivot Bracket: No Bracket, Rod End: No Bracket, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)

The MB series medium duty tie rod cylinder offers an improved design that enhances cylinder operation and ease of use. The standard air cushion utilizes a floating cushion seal to eliminate piston rod bouncing. The cushion volume has been elevated permitting about 30% more allowable kinetic energy absorption. The port and captive cushion adjustment valve are located on the same side of cap

The MB series medium duty tie rod cylinder offers an improved design that enhances cylinder operation and ease of use. The standard air cushion utilizes a floating cushion seal to eliminate piston rod bouncing. The cushion volume has been elevated permitting about 30% more allowable kinetic energy absorption. The port and captive cushion adjustment valve are located on the same side of cap

Operating Conditions Cylinder MY1H40-500Z Average operating speed a 300 mm/s Mounting orientation Wall mounting Cushion Air cushion ( = 1/100) Mounting Orientation z 1. Horizontal mounting 2. Wall mounting y x y x z MY1H40-500Z Wb: MGGLB25-200 (4.35 kg) 3. Ceiling mounting 4.

AL With One Unit A & One Unit L each AH With One Unit A & One Unit H each LH With One Unit L & One Unit H each ACCESSORIES AUTO SWITCHES Note: Pre-wired Switches with 3/4 Pin Connectors available Bore Size Model Switch Type Load Voltage Load Current Power Internal Voltage Indicator Grommet Connector Source Drop Lamp 16 & 20 D-A90L Reed 24 V/48V/100 V AC/DC 50mA/40mA/20mA None 16 & 20 D-A93L

Thrust energy E2 Fs Fs+Mgs Fs-Mgs Absorption energy E3 ACCESSORIES AUTO SWITCHES E1+E2 Note: Pre-wired Switches with 3/4 Pin Connectors available, please consult SMC Customer Service Bore Model Switch Load Load Power Internal Indicator Size Grommet Connector Type Voltage Current Source Voltage drop Lamp 16 & 20 D-A90L Reed 24V AC/DC 50 mA None 48V AC/DC 40mA 100V AC/DC 20 mA 16 & 20 D-A93L

Magnet: D (Built-in Magnet), Mounting: F (Rod Flange), Bore: 32mm, Port Thread: Rc, Stroke: 500mm, Cushion: Rod Boot None; Air Cushion on Both Sides

Magnet: Built-in Magnet, Mounting: Rod Flange, Bore: 32mm, Port Thread: Rc, Stroke: 500mm, Cushion: Rod Boot None; Air Cushion on Both Sides, Pivot Bracket: -, Rod End: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

A93 M9N M9P M9B F9NW F9PW F9BW F9BA A93V M9NV M9PV M9BV F9NWV F9PWV F9BWV 3-wire (NPN) 2-wire Relay, PLC 5 V, 12 V IC circuit 3-wire (PNP) 12 V 2-wire 24 V Relay, PLC 3-wire (NPN) 3-wire (PNP) Grommet 5 V, 12 V IC circuit Diagnostic indication (2-color indication) 12V 2-wire Water resistant (2-color indication) Lead wire length symbols: 0.5 m Nil (Example) A93 3 m L (Example) A93L

F9BA * Lead wire length 0.5m (Example) A93 3m L (Example) A93L 5m Z (Example) F9NWZ * : Manufactured upon receipt of order. 2.2-2 Compact Cylinder/Standard: Double Acting Single Rod Series CQS Specifications Style Pneumatic (Non-lube) Action Double acting, single rod Fluid Air Proof pressure 1.5MPa Max. operating pressure 1.0MPa Without auto switch 10C to 70C (No freezing) Ambient & fluid

Ultra low speed (7 to 50 mm/s) (kg) Bore size (mm) 6 10 15 20 25 32 40 0.231 0.428 0.743 1.317 1.641 2.870 4.508 Basic weight CY1S 0.053 0.082 0.111 0.184 0.186 0.284 0.430 Additional weight for 50 stroke CY3B CY3R 0.236 0.435 0.743 1.331 1.662 2.903 4.534 Basic weight CY1SG 0.050 0.079 0.108 0.176 0.178 0.273 0.411 Additional weight for 50 stroke CY1S CY1S Calculation: (Example) CY1SG25-500Z

This is a legacy product, and replaced byCY1SG32-500Z, CYL, RODLESS, SLIDER, SW CAP, ACTUATOR, CY1S GUIDED CYLINDER, LM, 32MM CY1S SLIDE BEARING, 13.22971 lb

This is a legacy product, and replaced byMDBT80-500Z-A53L, CYL, TIE ROD, AUTO-SW, ACTUATOR, MB TIE-ROD CYLINDER, RE, 80MM MB DBL-ACT AUTO-SW, 18.62906 lb

This is a legacy product, and replaced byMY1B32-500Z, CYL, RODLESS, MECH JOINT, ACTUATOR, MY1B GUIDED CYLINDER, LE, 32MM MY1B DBL-ACT AUTO-SW, 8.60924 lb