Bore Size: 25mm, Action: Single Acting N.O., Dust Cover: Chloroprene Rubber (CR), Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -

Bore Size: 25mm, Action: S (Single Acting N.O.), Dust Cover: Chloroprene Rubber (CR), Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)

Bore Size: 25mm, Action: S (Single Acting N.O.), Dust Cover: Chloroprene Rubber (CR), Auto Switch: M9NWV--Solid State, 2-color Indication, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)

Bore Size: 25mm, Action: S (Single Acting N.O.), Dust Cover: Chloroprene Rubber (CR), Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)

Please contact us for the latest version.sales@ocaire.com, GRIPPER, W/DUST COVER, ACTUATOR, MHQJ2 GRIPPER, IT, 25MM MHQJ2 SGL ACT AUTO-SW, .00000 lb, Operating systemModelCylinder bore (mm)Note 1)Gripping force(Effective value) NOpening/Closing stroke (mm)Note 2)Mass (g)Single actingNormally openMHQJ2-25S25491/4643

Please contact us for the latest version.sales@ocaire.com, GRIPPER, W/DUST COVER, ACTUATOR, MHQJ2 GRIPPER, IT, 25MM MHQJ2 SGL ACT AUTO-SW, 1.76369 lb, Operating systemModelCylinder bore (mm)Note 1)Gripping force(Effective value) NOpening/Closing stroke (mm)Note 2)Mass (g)Single actingNormally openMHQJ2-25S25491/4643

Please contact us for the latest version.sales@ocaire.com, GRIPPER, W/DUST COVER, ACTUATOR, MHQJ2 GRIPPER, IT, 25MM MHQJ2 SGL ACT AUTO-SW, 1.76369 lb, Operating systemModelCylinder bore (mm)Note 1)Gripping force(Effective value) NOpening/Closing stroke (mm)Note 2)Mass (g)Single actingNormally openMHQJ2-25S25491/4643

) (mm) Action Model Cylinder bore (mm) (Note 2) Weight (g) MHQJ2-10D 10 10.7(1.1) 4 90 B O R E S I Z E MHQJ2-16D 16 34.3(3.5) 6 180 Double acting 10 10mm 16 16mm 20 20mm 25 25mm MHQJ2-20D 20 42.2(4.3) 10 340 MHQJ2-25D 25 62.8(6.4) 14 640 Note 1: At 0.5MPa The outside and inside holding forces for the double acting type are indicated.

) (mm) Action Model Cylinder bore (mm) (Note 2) Weight (g) MHQJ2-10D 10 10.7(1.1) 4 90 B O R E S I Z E MHQJ2-16D 16 34.3(3.5) 6 180 Double acting 10 10mm 16 16mm 20 20mm 25 25mm MHQJ2-20D 20 42.2(4.3) 10 340 MHQJ2-25D 25 62.8(6.4) 14 640 Note 1: At 0.5MPa The outside and inside holding forces for the double acting type are indicated.

How to Order MHZ Bore size MHF MHS 3 D 20 16 to 25 M9N MHL Number of auto switches MHR Nil S 2 pcs. 1 pc.

Station 3 1 13 47.04 Station 4 Station 5 Connector JBZ-25S-3 made by Station 6 J.S.T. Mfg. Co.,Ltd. 1425 Socket side Station 7 Station 8 22 Terminal no.

MHZ2-6S/MHZA2-6S MHZ2-25S/MHZL2-25S 4 80 Pressure 0.7 MPa Pressure 0.7 MPa Pressure 0.7 MPa Pressure 0.7 MPa Gripping force (N) Gripping force (N) MHZ 0.6 MPa 0.6 MPa 3 60 0.6 MPa 0.6 MPa 0.5 MPa 0.5 MPa MHF 0.5 MPa 0.5 MPa F 2 40 0.4 MPa 0.4 MPa 0.4 MPa 0.4 MPa MHL 0.3 MPa 0.3 MPa 1 20 0.3 MPa 0.3 MPa MHR 0.25 MPa 0.25 MPa 0 10 20 30 0 20 40 60 80 100 MHK Gripping point L (mm) Gripping point

MHZ2-6S/MHZA2-6S MHZ2-25S/MHZL2-25S 4 80 Pressure 0.7 MPa Pressure 0.7 MPa Pressure 0.7 MPa Pressure 0.7 MPa Gripping force (N) Gripping force (N) MHZ 0.6 MPa 0.6 MPa 3 60 0.6 MPa 0.6 MPa 0.5 MPa 0.5 MPa MHF 0.5 MPa 0.5 MPa F 2 40 0.4 MPa 0.4 MPa 0.4 MPa 0.4 MPa MHL 0.3 MPa 0.3 MPa 1 20 0.3 MPa 0.3 MPa MHR 0.25 MPa 0.25 MPa 0 10 20 30 0 20 40 60 80 100 MHK Courtesy of Steven Engineering,

S D 1 F MHKL 2 20 S D 1 F M9N Long stroke type Number of auto switches Number of fingers Nil S 2 pcs. 1 pc.

resistant F9BA (2-color indication) Lead wire length symbols: 0.5 m Nil (Example) M9N 3 m L (Example) M9NL 5 m Z (Example) M9NZ Auto switches marked with a symbol are produced upon receipt of order.

Description FGGS NBR (Part no.: AL-25S) FKM (Part no.: AL-22S) FGGL 1 O-ring Refer to pages 256 and 257 for the replacement element type. Case fastening parts V-band coupling (Part no.: CY-27S) Note) The quantity used for 1 filter is 1 each of the above O-ring etc.

Model Bore size (mm) Gripping moment (Nm) (Effective value) (1) Opening/closing angle (Both sides) Weight (2) (g) Action Model MHC2-10D MHC2-16D MHC2-20D MHC2-25D 39 91 180 311 0.10 0.39 0.70 1.36 10 16 20 25 30 to 10 Double acting MHC2-10S MHC2-16S MHC2-20S MHC2-25S 0.070 0.31 0.54 1.08 39 92 183 316 10 16 20 25 MHC2-16S 30 to 10 Single acting Note 1) At the pressure of 0.5 MPa.

Model Bore size (mm) Gripping moment (Nm) (Effective value) (1) Opening/closing angle (Both sides) Weight (2) (g) Action Model MHC2-10D MHC2-16D MHC2-20D MHC2-25D 39 91 180 311 0.10 0.39 0.70 1.36 10 16 20 25 30 to 10 Double acting MHC2-10S MHC2-16S MHC2-20S MHC2-25S 0.070 0.31 0.54 1.08 39 92 183 316 10 16 20 25 MHC2-16S 30 to 10 Single acting Note 1) At the pressure of 0.5 MPa.

How Grip: Pinch, Parallel Type, Number of Fingers: 2 Pcs., Open Dimension L1(mm): 33, Closed Dimension L2(mm): 19, Type: [Main Body] Body, Operation Method: Single Acting Type (Normally Open), Main Body Shape: Square Shape, Gripping Force (Closed Side at 0.5 Mpa)(N): 49, Gripping Force (Open Side at 0.5 Mpa)(N): -, Environment, Applications: Dust Resistant / Drip-Proof, Additional Function