Your search for MXJ returned 30 result(s)
There were no hits with the full part number, but there were 2 hits in the keyword search.
There were no hits with the full part number, but there were 3 hits in the keyword search.
Product Information » New Products Search Results
J I 12 Z ZZ H G 3 +0.03 0 depth 2 GA A 19 3.3 3.5 A 5.8 4 x M4 x 0.7 3 4 3 +0.05 0 depth 2.5 A-A Model G GA H I J K M Z ZZ 11-MXJ8-5 11-MXJ8-10 11-MXJ8-15 11-MXJ8-20 12 18 17 6 17 28.5 44.5 38 45 12 18 17 6 17 28.5 44.5 38 45 19 28 20 8 25 39.5 54.5 48 55 Other dimensions are the same as standard model (Series MXJ). 19 28 20 8 25 39.5 54.5 48 55 829 Air Slide Table 11-MXJ Made to Order Air
and 5C, prevent water droplets from entering the inlet port.
COIL NO. 6 7.8 8.5 12 14 5.4 7 7.7 11 13 3 3.8 4.4 6 7 5C-103-A24 5C-104-A24 5C-105-A24 5C-106-A24 5C-107-A24 5C-3-K24 5C-4-K24 5C-5-K24 5C-6-K24 5C-7-K24 18.5 24 32 39 45 17 22 29 35 41 9 12 16 20 23 5C-108-A24 5C-109-A24 5C-110A24 5C-111-A24 5C-112-A24 5C-8-K24 5C-9-K24 5C-10-K24 5C-11-K24 5C-12-K24 48 54 94 120 153 43 48 85 110 138 24 28 47 60 76 5C-113-A24 5C-114-A24 5C-115-A24 5C-116
Specification: Standard Type (Not Clean Room), Bore Size: 8 mm, Symmetric Type: Standard, Stroke: 5mm, Adjuster: Metal Stopper Both Ends, Function: -, Switch Rail: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Specification: Standard Type (Not Clean Room), Bore Size: 8 mm, Symmetric Type: Standard, Stroke: 5mm, Adjuster: C (Metal Stopper Both Ends)
5C 100 100 Ambient temperature Ambient temperature Ambient temperature Ambient temperature 0 0 10 15 25 20 30 40 35 10 15 25 20 30 40 35 Circulating fluid temperature [C] Circulating fluid temperature [C] HRR010-W-20 [50 Hz] [60 Hz] 400 400 35C Heating capacity [W] Heating capacity [W] 35C 300 300 25C 25C 200 200 5C 5C 100 100 Facility water temperature Facility water temperature Facility
Temperature conditions Water (Standard) Air (Standard) Oil (Standard) Vacuum (3) (V, M) Maximum Minimum 40 1 60 5(1) 40 5 40 40 5 5(2) Pilot port Note 1) Dew point: 5C or less Note 2) 500 cSt or less Note 3) V, M in parentheses are option symbols.
O When the ambient temperature is 20C 5C and rated voltage is applied. P Coil change from AC to DC or DC to AC is impossible because the iron core shapes are different.
OFF 1 5C 3 Check the effect of ambient temperature. Please review the setting value. There may be causes such as large load fluctuation and flow rate fluctuation. Please review the setting value.
OFF 1 5C 3 Check the effect of ambient temperature. Please review the setting value. There may be causes such as large load fluctuation and flow rate fluctuation. Please review the setting value.
Water 15% Ethylene Glycol Aqueous Solution Physical property value Temperature Density [kg/L] Specific heat C [J/(kgK)] Current unit system Physical property value Temperature Density [kg/L] Specific heat C [J/(kgK)] Current unit system Weight volume ratio [kgf/L] Specific heat C [cal/(kgfC)] 5C 1.00 4.2 x 103 1.00 1 x 103 Weight volume ratio [kgf/L] Specific heat C [cal/(kgfC)] 5C 1.02
Water 15% Ethylene Glycol Aqueous Solution Physical property value Temperature Density [kg/L] Specific heat C [J/(kgK)] Current unit system Physical property value Temperature Density [kg/L] Specific heat C [J/(kgK)] Current unit system Weight volume ratio [kgf/L] Specific heat C [cal/(kgfC)] 5C 1.00 4.2 x 103 1.00 1 x 103 Weight volume ratio [kgf/L] Specific heat C [cal/(kgfC)] 5C 1.02
Water 15% Ethylene Glycol Aqueous Solution Physical property value Temperature Density [kg/L] Specific heat C [J/(kgK)] Current unit system Physical property value Temperature Density [kg/L] Specific heat C [J/(kgK)] Current unit system Weight volume ratio [kgf/L] Specific heat C [cal/(kgfC)] 5C 1.00 4.2 x 103 1.00 1 x 103 Weight volume ratio [kgf/L] Specific heat C [cal/(kgfC)] 5C 1.02
Note 3) The values are for ambient temperature of 20C 5C and rated voltage. Note 4) AC to DC or DC to AC coil exchange is not possible due to different armature configuration. Note 5) Values for apparent power inside ( ) are for VXZ2232.
Take measures to prevent moisture from freezing in circuits when below 5C, since this may cause damage to the O-ring and lead to a malfunction. The installation of an air dryer is recommended for eliminating condensate and moisture.
11-MXJ8(L)Without adjusterGrade 3 (Class 100 or equivalent)1