There were no hits with the full part number, but there were 19 hits in the keyword search.
There were no hits with the full part number, but there were 4 hits in the keyword search.
Product Information » New Products Search Results
Bore Size: 40mm, Port Thread: TN (NPT), Piping: Standard, Stroke: 300mm, Stroke Adjustment Unit: H (Left: w/High Load Shock Absorber & Adjustment Bolt; Right: w/High Load Shock Absorber & Adjustment Bolt)
Type: Rodless Cylinder, Cylinder Inner Diameter(Ø): 40, Stroke(mm): 300, Max. Load Mass (Horizontal Mounting)(kg): 40~57, Table Size Length L(mm): 170, Table Material: [Aluminum] Aluminum Alloy, Rodless Cylinder Joint Type: Mechanically Jointed, Guide: [Guideless] Prototype, Table Size Width W(mm): 64, Table Size Height H(mm): 84, Table Surface Treatment: [Anodize] Hard Anodize, Environment
Bore Size: 40mm, Port Thread: TF (G), Piping: Standard, Stroke: 300mm, Stroke Adjustment Unit: H (Left: w/High Load Shock Absorber & Adjustment Bolt; Right: w/High Load Shock Absorber & Adjustment Bolt), Auto Switch: M9NW--Solid State, 2-color Indication, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector)
Bore Size: 40mm, Port Thread: G, Piping: Standard, Stroke: 300mm, Stroke Adjustment Unit: Left: w/High Load Shock Absorber & Adjustment Bolt; Right: w/High Load Shock Absorber & Adjustment Bolt, Auto Switch: M9NW--Solid State, 2-color Indication, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M12-4 Pin Connector, Number: -
Note 2) Vibration resistance Conditions when tested with one sweep of 10 to 300Hz in the axial direction and at a right angle to the armature, in both energized and deenergized states Impact resistance Conditions when tested with a drop tester in the axial direction and at a right angle to the armature, one time each in energized and deenergized states Characteristic Specifications Maximum
Note 2) Vibration resistance Conditions when tested with one sweep of 10 to 300Hz in the axial direction and at a right angle to the armature, in both energized and deenergized states Impact resistance ...Conditions when tested with a drop tester in the axial direction and at a right angle to the armature, one time each in energized and deenergized states Characteristic Specifications Note
, 110VAC, 200VAC, 220VAC, 230VAC (50/60Hz) Allowable voltage fluctuation 10% of rated voltage Coil insulation type Class H Power consumption W 50/60Hz VCB2: 4.9/4.1, VCB3: 7.7/6.6, VCB4: 10.5/9.3 Inrush VCB2: 22/19, VCB3: 36/30, VCB4: 45/37 Apparent power VA 50/60Hz VCB2: 10/8, VCB3: 15/13, VCB4: 19/16 Holding Note 1) Vibration resistance Conditions when tested with one sweep of 10 to 300Hz
PB53] 1 Hz 300 Hz 300Hz 1 1 [Pr. PB20] ( () ) [Pr. PB19] -90 deg. 7 11 7. (b) () () t t [Hz] [Hz] [Hz] [Hz] 3. 7.1.6 3 4.5Hz2250Hz [Pr. PB45 ] ()150ms (1) t t 7 12 7. (2) Pr. PB45 ] [Hz] [Pr.
Op Frequency 300Hz), Lead Wire: G (300 mm)
Op Frequency 300Hz), Lead Wire: J (1000 mm)
Note 2) Vibration resistance Conditions when tested with one sweep of 10 to 300Hz in the axial direction and at a right angle to the armature, in both energized and deenergized states Impact resistance Conditions when tested with a drop tester in the axial direction and at a right angle to the armature, one time each in energized and deenergized states Characteristic Specifications Maximum
, 110VAC, 200VAC, 220VAC, 230VAC (50/60Hz) Allowable voltage fluctuation 10% of rated voltage Coil insulation type Class H Power consumption W 50/60Hz VCB2: 4.9/4.1, VCB3: 7.7/6.6, VCB4: 10.5/9.3 Inrush VCB2: 22/19, VCB3: 36/30, VCB4: 45/37 Apparent power VA 50/60Hz VCB2: 10/8, VCB3: 15/13, VCB4: 19/16 Holding Note 1) Vibration resistance Conditions when tested with one sweep of 10 to 300Hz
Note 2) Vibration resistance Conditions when tested with one sweep of 10 to 300Hz in the axial direction and at a right angle to the armature, in both energized and deenergized states Impact resistance ...Conditions when tested with a drop tester in the axial direction and at a right angle to the armature, one time each in energized and deenergized states Characteristic Specifications Note
Op Frequency 300Hz), Lead Wire: J (1000 mm)
Op Frequency 300Hz), Lead Wire: G (300 mm)