Delay time selection of contact signal alarm delay time of 0 to 300s OFF detection time selection of contact signal alarm off detection time of 0 to 10s Table 2-5 Setting of contact input signal form Type Display Item Setting Upper line SEL INP.1 Signal type OFF:Disabled, RN.ST:Run/Stop signal, RUNRun signal, SWExternal switch signal Lower line(Initial value) RN.ST Upper line TYPE INP.1
Magnet: D (Built-in), Mounting: F (Flange), Bore: Ø16 (5/8 Inch), Stroke: 300 (3 Inch), Action: S (Spring Return), Port Location: Perpendicular, Auto Switch: H7A2--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)
Magnet: Built-in, Mounting: Flange, Bore: Ø16 (5/8 Inch), Stroke: 3 Inch, Action: Spring Return, Port Location: Perpendicular, Auto Switch: H7A2--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 1 pc.
This is a legacy product, and replaced byCDJ2D16-20Z-H7A2S-B, CYL, RND BODY, D/CLVS, D/ACT, ACTUATOR, CJ2 ROUND BODY CYLINDER, GE, 16MM CJ2 DBL-ACT AUTO-SW, .22573 lb
Magnet: D (Built-in), Mounting: L (Foot), Bore: Ø16 (5/8 Inch), Stroke: 300 (3 Inch), Action: S (Spring Return), Port Location: Perpendicular, Auto Switch: C73--Reed, DC Volt >5 <24, AC Volt <100, LED
Magnet: D (Built-in), Mounting: L (Foot), Bore: Ø16 (5/8 Inch), Stroke: 300 (3 Inch), Action: S (Spring Return), Port Location: Perpendicular, Auto Switch: C73--Reed, DC Volt >5 <24, AC Volt <100, LED, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)
Magnet: D (Built-in), Mounting: L (Foot), Bore: Ø16 (5/8 Inch), Stroke: 300 (3 Inch), Action: S (Spring Return), Port Location: Perpendicular, Auto Switch: H7A2--Solid State, Gen. Purpose, 3 Wire PNP
Magnet: D (Built-in), Mounting: L (Foot), Bore: Ø16 (5/8 Inch), Stroke: 300 (3 Inch), Action: S (Spring Return), Port Location: Perpendicular, Auto Switch: B (Band Mounting)
Magnet: D (Built-in), Mounting: L (Foot), Bore: Ø16 (5/8 Inch), Stroke: 300 (3 Inch), Action: S (Spring Return), Port Location: Perpendicular, Auto Switch: H7A2--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire or Prewired Connector: Z (5m), Number: S (1 pc.)
Magnet: Built-in, Mounting: Foot, Bore: Ø16 (5/8 Inch), Stroke: 3 Inch, Action: Spring Return, Port Location: Perpendicular, Auto Switch: C73--Reed, DC Volt >5 <24, AC Volt <100, LED, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in, Mounting: Foot, Bore: Ø16 (5/8 Inch), Stroke: 3 Inch, Action: Spring Return, Port Location: Perpendicular, Auto Switch: C73--Reed, DC Volt >5 <24, AC Volt <100, LED, Lead Wire or Prewired Connector: 3m, Number: 1 pc.
Magnet: Built-in, Mounting: Foot, Bore: Ø16 (5/8 Inch), Stroke: 3 Inch, Action: Spring Return, Port Location: Perpendicular, Auto Switch: H7A2--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in, Mounting: Foot, Bore: Ø16 (5/8 Inch), Stroke: 3 Inch, Action: Spring Return, Port Location: Perpendicular, Auto Switch: Band Mounting, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in, Mounting: Foot, Bore: Ø16 (5/8 Inch), Stroke: 3 Inch, Action: Spring Return, Port Location: Perpendicular, Auto Switch: H7A2--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire or Prewired Connector: 5m, Number: 1 pc.
temperature (C) Voltage & power consumption 10% Installation features 0.3 to 1.0 0.3 to 0.9 5 to 50 2 to 50 100 VAC, 200 VAC (50/60 Hz) 30 W Indoor Note) Inlet air pressure: 0.7 MPa, Inlet air temperature: 35C, Outlet air dew point (atmospheric pressure): 30C Accessory (Option)/Replacement Parts ID20 ID30 ID40 ID60 Applicable model 6604113 6604113 660651 660651 AM150 AM250 AM250 AM350 ID-200S ID-300S
temperature (C) Voltage & power consumption 10% Installation features 0.3 to 1.0 0.3 to 0.9 5 to 50 2 to 50 100 VAC, 200 VAC (50/60 Hz) 30 W Indoor Note) Inlet air pressure: 0.7 MPa, Inlet air temperature: 35C, Outlet air dew point (atmospheric pressure): 30C Accessory (Option)/Replacement Parts ID20 ID30 ID40 ID60 Applicable model 6604113 6604113 660651 660651 AM150 AM250 AM250 AM350 ID-200S ID-300S
(Inlet air pressure: 0.7 MPa, Inlet air temperature: 20C) Accessory (Option)/Replacement Parts Applicable model ID20 ID30 ID40 ID60 6604113 6604113 660651 660651 ID-200S ID-300S ID-400S ID-600S ID-200Z ID-300Z ID-400Z ID-600Z ID-DPM8 Bracket Adsorbent set Note) Adsorbent set (for low dew point) Note) Indicator set Note) Adsorbent and adsorption tube filter for one air dryer (two adsorption
Standard dew point 22F (30C) Adsorbent set for standard dew point 4.7 4.7 6.7 6.7 ID-200S ID-300S ID-400S ID-600S Dimensions 240 240 320 320 9.4 9.4 12.6 12.6 520 615 850 961 Heatless Air Dryer Series ID AM150-N02 AM250-N04 AM250-N04 AM350-N06 Mist separator Model Compact and light weight without heater and electric control board 20.5 24.2 33.5 37.8 110V Single-Phase 60hz Bracket 6604113
Magnet: D (Built-in), Mounting: L (Foot), Bore Size: Ø16 (5/8"), Stroke: 050 (1/2"), Port Location: Perpendicular, Auto Switch: H7A2--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire, 0.5M, Number: S (1 pc.)
Magnet: D (Built-in), Mounting: L (Foot), Bore Size: Ø16 (5/8"), Stroke: 100 (1"), Port Location: Perpendicular, Auto Switch: H7A2--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire, 0.5M, Number: S (1 pc.)