Your search for NCM returned 30 result(s)
There were no hits with the full part number, but there were 0 hits in the keyword search.
There were no hits with the full part number, but there were 1 hits in the keyword search.
Product Information » New Products Search Results
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 075 (3/4 Inch), Stroke: 0100 (1 Inch), Cushion: No Cushion, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 075 (3/4 Inch), Stroke: 0100 (1 Inch), Cushion: No Cushion, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 075 (3/4 Inch), Stroke: 0100 (1 Inch), Cushion: No Cushion, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: Z (5m)
Magnet: Built-in, Mounting: Basic, Bore Size: 3/4 Inch, Stroke: 1 Inch, Cushion: No Cushion, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -
Magnet: Built-in, Mounting: Basic, Bore Size: 3/4 Inch, Stroke: 1 Inch, Cushion: No Cushion, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 1 pc., Speed Control Type: -, Applicable Tubing: -, Suffix: -
Magnet: Built-in, Mounting: Basic, Bore Size: 3/4 Inch, Stroke: 1 Inch, Cushion: No Cushion, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 5m, Number: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -
Magnet: Built-in, Mounting: Basic, Bore Size: 3/4 Inch, Stroke: 1 Inch, Cushion: No Cushion, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Speed Control Type: Right Angle, Applicable Tubing: 1/4", Suffix: Required Selection w/Speed Control
Series NCM stainless steel cylinder offers space savings, high performance, and interchangeability with other stainless steel cylinders. A wear ring extends the seal life and a bronze rod bushing is standard on all bore sizes. The NCM is available in 4 mounting styles * as well as double rod and spring return or spring extend models. The NCM is auto-switch capable without any change in cylinder
Series NCM stainless steel cylinder offers space savings, high performance, and interchangeability with other stainless steel cylinders. A wear ring extends the seal life and a bronze rod bushing is standard on all bore sizes. The NCM is available in 4 mounting styles * as well as double rod and spring return or spring extend models. The NCM is auto-switch capable without any change in cylinder
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, .75 INCH NCM NON-ROT AUTO-SW, ACTUATOR, NCM ROUND BODY CYLINDER, HL, .75 INCH NCM NON-ROT AUTO-SW
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, .75 INCH NCM NON-ROT AUTO-SW, ACTUATOR, NCM ROUND BODY CYLINDER, HL, .75 INCH NCM NON-ROT AUTO-SW, 2.19214 lb
Please contact us for the latest version.sales@ocaire.com, NCDMKB075-0075, CDN SPL, ACTUATOR, NCM ROUND BODY CYLINDER, HL, .75 INCH NCM NON-ROT AUTO-SW, .00000 lb
D-A90(V)/D-A93(V)/D-A96(V) Direct Mounting Style .
When bank 2 is selected 0 0001 0010 0011 0100 0101 0110 0111 1000 1001 BCD Ex.) 1294.53 is expressed as follows. 0001 0010 1001 0100 0101 0011 16 17 18 19 20 Bank 2 Bank 3 Bank 4 11 12 13 14 15 6 7 8 9 10 1 2 3 4 5 Bank 1 RS-232C This is the interface standard for the serial transmission method, which is standard equipment on a personal computer.
When bank 2 is selected Decimal no. 1 2 3 4 5 6 7 8 9 0 BCD 0 0001 0010 0011 0100 0101 0110 0111 1000 1001 16 17 18 19 20 Bank 2 Bank 3 Bank 4 11 12 13 14 15 Ex.) 1294.53 is expressed as follows. 0001 0010 1001 0100 0101 0011 6 7 8 9 10 Bank 1 1 2 3 4 5 RS-232C 1 2 3 4 5 Output terminal 6 7 8 9 10 Preset no.
When bank 2 is selected 0 Decimal no. 1 2 3 4 5 6 7 8 9 Bank 2 Bank 3 Bank 4 16 17 18 19 20 BCD 0 0001 0010 0011 0100 0101 0110 0111 1000 1001 11 12 13 14 15 Ex.) 1294.53 is expressed as follows. 0001 0010 1001 0100 0101 0011 6 7 8 9 10 Bank 1 1 2 3 4 5 RS-232C 1 2 3 4 5 6 7 8 9 10 Output terminal This is the interface standard for the serial transmission method, which is standard equipment