Your search for NCQ2 returned 30 result(s)
There were no hits with the full part number, but there were 2 hits in the keyword search.
There were no hits with the full part number, but there were 1 hits in the keyword search.
Product Information » New Products Search Results
Magnet: Built-in, Rod Type: Standard, Mounting: B [Through Hole (Standard)], Bore Size: 50mm, Stroke: 45mm, Body Option: Rod End Male Thread, Auto Switch Groove: Auto Switch Mounting Grooves, Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -
Magnet: D (Built-in), Rod Type: Standard, Mounting: B [Through Hole (Standard)], Bore Size: 50mm, Stroke: 45mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)
SMC has redesigned the NCQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving ease and safety of work.Compact, double acting, single rod, large bore , Bore size (mm): 125,
Please contact us for the latest version.sales@ocaire.com, NCDQ2B50-20+50, CDN SPL, ACTUATOR, NCQ2 COMPACT CYLINDER, NE, 50MM NCQ2 DBL-ACT AUTO-SW, .00000 lb
This is a legacy product, and replaced byCDQ2B100-45DMZ, CYL, COMPACT *LQA, ACTUATOR, CQ2 COMPACT CYLINDER, SE, 100MM CQ2 DBL-ACT AUTO-SW, 7.10666 lb
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact, water resistant cylinder , Bore sizes
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact, water resistant cylinder , Bore sizes
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Without built-in magnet, Support
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Without built-in magnet, Support
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket: