Maximum measured Maximum measured Minimum measured Minimum measured Part no. flow rate value [l/min] flow rate value [l/min] flow rate value [l/min] flow rate value [l/min] PF2A510--1 PF2A550--1 PF2A511--1 PF2A521--1 PF2A551--1 PF2A510--2 PF2A550--2 PF2A511--2 PF2A521--2 PF2A551--2 10 50 100 200 500 10 50 100 200 500 1.1 5.4 11 21 54 10.7 53.5 107 214 535 1.1 5.4 11 21 54 10.7 53.5 107 214
Maximum measured Maximum measured Minimum measured Minimum measured Part no. flow rate value [l/min] flow rate value [l/min] flow rate value [l/min] flow rate value [l/min] PF2A510--1 PF2A550--1 PF2A511--1 PF2A521--1 PF2A551--1 PF2A510--2 PF2A550--2 PF2A511--2 PF2A521--2 PF2A551--2 10 50 100 200 500 10 50 100 200 500 1.1 5.4 11 21 54 10.7 53.5 107 214 535 1.1 5.4 11 21 54 10.7 53.5 107 214
Connector pin numbers PF2W504T--1 PF2W520T--1 PF2W540T--1 PF2W504T--2 PF2W520T--2 PF2W540T--2 4 0.5 4 0.5 4 3 16 2 16 2 40 5 40 5 2 1 Pin no.
flow Min. measured flow Max. measured flow Min. measured flow Max. measured flow Min. measured flow Max. measured flow Part no. rate value [l/min] Part no. rate value [l/min] rate value [l/min] rate value [l/min] rate value [l/min] rate value [l/min] rate value [l/min] rate value [l/min] PF2A510--1 PF2A550--1 PF2A511--1 PF2A521--1 PF2A551--1 PF2A510--2 PF2A550--2 PF2A511--2 PF2A521--2 PF2A551
Connector pin numbers PF2W504T--1 PF2W520T--1 PF2W540T--1 PF2W504T--2 PF2W520T--2 PF2W540T--2 4 0.5 4 0.5 4 3 16 2 16 2 40 5 40 5 2 1 Pin no.
Input of the Set point 2 L/min, L CFM x 10-2, CFM x 10-1, ft3 x 10-2, ft3 x 10-1, gal(US)/min, gal(US) 1 Brown DC(+) Non-Reverse output Reverse output Refer to the product catalogue or SMC website (URL http://www.smcworld.com) for more information about panel cut-out dimensions.
Hysteresis mode 2 Panel Item Default settings Model button (UP) Panel mount adapter Item Default setting ( ) PF2A30 series [10L] 1 to 10 L/min type (PF2A510) Indicator LED (OUT1) Set point 1 Set point 2 Hysteresis 1 Hysteresis 1 50% of max. rated flow [n_1] Input of the Set point 1 (OUT1) PF2A31 series [11L] 10 to 100 L/min type (PF2A511) button (SET) ON 50% of max. rated flow [n_2] Input
(In case of output OUT2, n_1, 2 to be n_3, 4 and P_1, 2 to be P_3, 4.)
Main circuit Brown DC(+) + Connector 2 6 Blue DC(-) 12 to 24 VDC 2 1 5 Metal piping attachment 1 DC(+) To obtain more detailed information about operating this product, please refer to the SMC website (URL http://www.smcworld.com) or contact SMC directly. 2 N.C. / Analogue output : This drawing is the model of PF2W504/520.
Flow Range: 1~10l/min, Thread: Rc, Port Size: Port Size 1/8, Wiring Specification: w/o Lead Wire, Output Specification: -
Flow Range: 10 (1~10l/min), Thread: Rc, Port Size: 01 (Port Size 1/8), Wiring Specification: N (w/o Lead Wire)
Flow Range: 0 (PF2A510: 1-10l/min, PF2A550: 5-50l/min), Output Specification: 0 (NPN Open Collector 2 Outputs), Unit: M (S1 Fixed Unit)
Flow Range: 0 (PF2A510: 1-10l/min, PF2A550: 5-50l/min), Output Specification: 0 (NPN Open Collector 2 Outputs)
Flow Range: 0 (PF2A510: 1-10l/min, PF2A550: 5-50l/min), Output Specification: 1 (PNP Open Collector 2 Outputs)
Flow Range: 0 (PF2A510: 1-10l/min, PF2A550: 5-50l/min), Output Specification: 1 (PNP Open Collector 2 Outputs), Unit: M (S1 Fixed Unit)