Product Information ยป New Products Search Results
PF2W504--1 PF2W520--1 PF2W540--1 PF2W511--1 PF2W504--2 PF2W520--2 PF2W540--2 PF2W511--2 4 0.5 4 0.5 16 2 16 2 40 5 40 5 100 10 100 10 16-11-24 21 Series PF2W Digital Flow Switch For Water Dimensions: Remote Type Display Unit for Water PF2W3-A Panel mounting type Internal circuit and wiring example to are terminal numbers.
PF2W504--1 PF2W520--1 PF2W540--1 PF2W511--1 PF2W504--2 PF2W520--2 PF2W540--2 PF2W511--2 4 0.5 4 0.5 16 2 16 2 40 5 40 5 100 10 100 10 16-11-24 21 Series PF2W Digital Flow Switch For Water Dimensions: Remote Type Display Unit for Water PF2W3-A Panel mounting type Internal circuit and wiring example to are terminal numbers.
PF2W504--1 PF2W520--1 PF2W540--1 PF2W511--1 PF2W504--2 PF2W520--2 PF2W540--2 PF2W511--2 4 0.5 4 0.5 16 2 16 2 40 5 40 5 100 10 100 10 19 Series PF2W For Water Digital Flow Switch to are terminal numbers.
PF2W504--1 PF2W520--1 PF2W540--1 PF2W511--1 PF2W504--2 PF2W520--2 PF2W540--2 PF2W511--2 4 0.5 4 0.5 16 2 16 2 40 5 40 5 100 10 100 10 310 A Series PF2W For Water Digital Flow Switch Dimensions: Remote Type Monitor Unit For Water PF2W3-A Panel mount adapter type Internal Circuits and Wiring Examples -0 NPN (2 outputs) Position Detection Switch Flow Sensor Pressure Control Pressure Sensor 41.8
PF2W504--1 PF2W520--1 PF2W540--1 PF2W511--1 PF2W504--2 PF2W520--2 PF2W540--2 PF2W511--2 4 0.5 4 0.5 16 2 16 2 40 5 40 5 100 10 100 10 19 Series PF2W For Water Digital Flow Switch Dimensions: Remote Type Display Unit for Water PF2W3-A Panel mounting type Internal circuits and wiring examples OUT2 NC Sensor 8 Load 41.8 4 4.3 40.3 OUT1 40 Black Main circuit Main circuit 7 3 Load Brown 6 2 +
PF2W504--1 PF2W520--1 PF2W540--1 PF2W511--1 PF2W504--2 PF2W520--2 PF2W540--2 PF2W511--2 4 0.5 4 0.5 16 2 16 2 40 5 40 5 100 10 100 10 23 Digital Flow Switch Series PF2W For Water Dimensions: Remote Type Display Unit for Water PF2W3-A Panel mounting type Internal circuits and wiring examples to are the terminal numbers.
to 186 1.0 to 38.0 2 to 76 8 to 186 CFM x 10-2 CFM x 10-2 CFM x 10-1 CFM x 10-1 CFM x 10-1 flow Flow Min. setting/display unit 0.5 2.0 0.5 1.0 2.0 CFM x 10-2 CFM x 10-2 CFM x 10-1 CFM x 10-1 CFM x 10-1 Accumulated Setting/display flow range 0 to 9 ft3 x 10-2 0 to 9 ft3 x 10-1 flow Min. setting/display unit 1 ft3 x 10-3 1 ft3 x 10-1 Conversion of accumulated pulse 0.5 2.0 0.5 1.0 2.0 ft3 x
1.0 to 38.0 2 to 76 8 to 186 CFM x 10-2 CFM x 10-2 CFM x 10-1 CFM x 10-1 CFM x 10-1 flow Flow Min. setting/display unit 0.5 2.0 0.5 1.0 2.0 CFM x 10-2 CFM x 10-2 CFM x 10-1 CFM x 10-1 CFM x 10-1 Accumulated Setting/display flow range 0 to 9 ft3 x 10-2 0 to 9 ft3 x 10-1 flow Min. setting/display unit 1 ft3 x 10-3 1 ft3 x 10-1 Conversion of accumulated pulse 0.5 2.0 0.5 1.0 2.0 ft3 x 10-2/
Hysteresis mode 2 Panel Item Default settings Model button (UP) Panel mount adapter Item Default setting ( ) PF2A30 series [10L] 1 to 10 L/min type (PF2A510) Indicator LED (OUT1) Set point 1 Set point 2 Hysteresis 1 Hysteresis 1 50% of max. rated flow [n_1] Input of the Set point 1 (OUT1) PF2A31 series [11L] 10 to 100 L/min type (PF2A511) button (SET) ON 50% of max. rated flow [n_2] Input
set unit Note 1) Accumulated pulse flow rate exchange value (Pulse width: 50 ms) Note 1) 0.1 l/pulse 0.5 l/pulse 1 l/pulse 2 l/pulse 5 l/pulse l/min, CFM x 10-2 l, ft3 x 10-2 l/min, CFM x 10-1 l, ft3 x 10-1 Display units Real-time flow rate Accumulated flow Note 1, 2) 0 to 9 l, 0 to 9 ft3 x 10-2 0 to 9 l, 0 to 9 ft3 x 10-1 Accumulated flow range Note 1) Power supply voltage Current consumption
Input of the Set point 2 L/min, L CFM x 10-2, CFM x 10-1, ft3 x 10-2, ft3 x 10-1, gal(US)/min, gal(US) 1 Brown DC(+) Non-Reverse output Reverse output Refer to the product catalogue or SMC website (URL http://www.smcworld.com) for more information about panel cut-out dimensions.
Flow Range: 3 (PF2W511: 10~100), Output Specification: 1 (PNP Open Collector 2 Outputs)
Flow Range: 3 (PF2W511: 10~100), Output Specification: 1 (PNP Open Collector 2 Outputs), Unit: M (S1 Fixed Unit)
White Analogue output Danger: Switch output 1 4 Installing Install the product (with bracket) using the M4 screws (4 pcs). Bracket thickness is approximately 1.6 mm (approximately 2.0 mm for PF2W511).
Flow Range: 3 (PF2W511: 10~100), Output Specification: 0 (NPN Open Collector 2 Outputs), Unit: M (S1 Fixed Unit)
Flow Range: 3 (PF2W511: 10~100), Output Specification: 0 (NPN Open Collector 2 Outputs)
Flow Range: PF2W511: 10~100, Output Specification: NPN Open Collector 2 Outputs, Unit: S1 Fixed Unit
Flow Range: PF2W511: 10~100, Output Specification: NPN Open Collector 2 Outputs, Unit: -
Flow Range: PF2W511: 10~100, Output Specification: PNP Open Collector 2 Outputs, Unit: -