Only air, N2, are applicable. [6000] 6000 L/min (PF3A712H) [F 1] [ 150] 150 L/min (PF3A703H) The accumulated flow has exceeded the accumulated flow range. (For accumulated increment) [H_1 ] Setting of Hysteresis [ 300] 300 L/min (PF3A706H) Do not use the product in a place where static electricity is a problem. Otherwise it can cause failure or malfunction of the system.
4 mA 4.16 mA 20 mA E F G Voltage output (0 to 10 V) 1 0 V 0.10 V 10 V 1: The analogue output current from the connected equipment should be 20 A or less when selecting 0 to 10 V.
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: Rc, Port Size: 10 (1), Output Specifications: CS (Out: NPN; Func: Analog Voltage Output <-> External Input)
Type: [Flow Switches] Flow Switch, Fluid Type: Air / Nitrogen Gas, Flow Range(l/min): 500~Less than 5000, Sensor, Monitor Structure: [Integrated Type] Display Integrated, Output Method: NPN Open Collector / Analog, Analog Output Specification: Voltage, Pipe Port Type: Female Thread, Plumbing Thread Type: [Rc (R)] Rc, Plumbing Thread Nominal: [1] 1, Pressure Type: Standard, Pressure Resistance
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: Rc, Port Size: 10 (1), Output Specifications: CS (Out: NPN; Func: Analog Voltage Output <-> External Input), Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: M (SI Unit Only)
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: Rc, Port Size: 10 (1), Output Specifications: CS (Out: NPN; Func: Analog Voltage Output <-> External Input), Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: M (SI Unit Only), Calibration Certificate: A (Made to Order)
Rated Flow Range: 30 to 3000 l/min, Thread Type: Rc, Port Size: 1, Output Specifications: Out: NPN; Func: Analog Voltage Output <-> External Input, Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: SI Unit Only, Calibration Certificate: -
Rated Flow Range: 30 to 3000 l/min, Thread Type: Rc, Port Size: 1, Output Specifications: Out: NPN; Func: Analog Voltage Output <-> External Input, Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: SI Unit Only, Calibration Certificate: Made to Order
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specifications: CS (Out: NPN; Func: Analog Voltage Output <-> External Input), Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: Units Selection Function, Calibration Certificate: A (Made to Order)
Rated Flow Range: 30 to 3000 l/min, Thread Type: NPT, Port Size: 1, Output Specifications: Out: NPN; Func: Analog Voltage Output <-> External Input, Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: Units Selection Function, Calibration Certificate: Made to Order
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specifications: CS (Out: NPN; Func: Analog Voltage Output <-> External Input)
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: F [G (ISO 1179-1 Compliant)], Port Size: 10 (1), Output Specifications: CS (Out: NPN; Func: Analog Voltage Output <-> External Input)
Rated Flow Range: 30 to 3000 l/min, Thread Type: NPT, Port Size: 1, Output Specifications: Out: NPN; Func: Analog Voltage Output <-> External Input, Lead Wire: -, Unit Specification: -, Calibration Certificate: -
Rated Flow Range: 30 to 3000 l/min, Thread Type: F [G (ISO 1179-1 Compliant)], Port Size: 1, Output Specifications: Out: NPN; Func: Analog Voltage Output <-> External Input, Lead Wire: -, Unit Specification: -, Calibration Certificate: -
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specifications: CS (Out: NPN; Func: Analog Voltage Output <-> External Input), Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: M (SI Unit Only)
Rated Flow Range: 30 to 3000 l/min, Thread Type: NPT, Port Size: 1, Output Specifications: Out: NPN; Func: Analog Voltage Output <-> External Input, Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: SI Unit Only, Calibration Certificate: -
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: F [G (ISO 1179-1 Compliant)], Port Size: 10 (1), Output Specifications: CS (Out: NPN; Func: Analog Voltage Output <-> External Input), Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: M (SI Unit Only)
As a rule, use electrical wire with a cross sectional area of 0.5 to 1.25 mm2 for wiring. 2. External force applied to the lead wire If an excessive force is applied to the lead wire, this may cause faulty wiring. Take appropriate measures so that a force of 10 N or more is not applied to the lead wire.
Inquire LSS Address This service allows the determination of the LSS Address parameters of a LSS Slave in configuration mode. cs: LSS command specifier (5Ah for Inquire Vendor-ID) cs: LSS command specifier (5Bh for Inquire Product-Code) cs: LSS command specifier (5Ch for Inquire Revision-Number) cs: LSS command specifier (5Dh for Inquire Serial-Number) reserved: reserved for further use by
MXQ12-10 MXQ12-10 MXQ12-10 MXQ12-10 0.01 0.02 0.004 0 0 0 160 40 80 120 20 40 60 80 100 20 40 60 80 100 Load (N) Load (N) Load (N) 8-5-12 13 Air Slide Table Series MXQ Table Displacement due to Pitch Moment Load Table Displacement due to Yaw Moment Load Table Displacement due to Roll Moment Load Displacement at A when a load is applied to F with the slide table retracted.