Product number Suitable screws Tightening torque Thread depth PF3A703H Equivalent to M4 1.5 Nm 10 7 PF3A706H Equivalent to M5 3 Nm 10 8 PF3A712H Equivalent to M6 5.2 Nm 10 9 Prepared by the user.

L/min 0 to 1 L/min 0 to 3 L/min 0.5 to 0.5 L/min 5 to 500 L/min 5 to 500 L/min 10 to 1000 L/min 20 to 2000 L/min 2 to 200 L/min 1 to 1 L/min 10 to 1000 L/min 3 to 3 L/min 20 to 2000 L/min Power supply voltage 24 VDC 10% 12 to 24 VDC 10% 12 to 24 VDC 10% 24 VDC 10% 12 to 24 VDC 10% 12 to 24 VDC 10% Temperature characteristics 2% F.S. 2% F.S. (15 to 35C) 2% F.S. (15 to 35C) (25C standard)

Item PF3A703H PF3A706H PF3A712H The operation manual is intended for those who have knowledge of machinery using pneumatic equipment, and have sufficient knowledge of assembly, operation and maintenance of such equipment. Only those persons are allowed to perform assembly, operation and maintenance.

Before Use Digital Flow Switch PF3A703H/PF3A706H/PF3A712H-L Use the correct tightening torque for piping. (Refer to the table below for the required torque values.) If the tightening torque is exceeded, the product can be damaged. If the tightening torque is insufficient, the fittings may become loose. Avoid any sealing tape getting inside the fluid passage.

Approx. 1.1 mm Insulator Colours Brown, blue, black, white Sheath Finish O.D. 4 -53No.PF-OMX0007-A Characteristics data Flow rate/Analogue output 0 L/min A 2 B 0 L/min C 2 D Voltage output (1 to 5 V) 1 1 V 1.04 V 5 V Voltage output (0 to 10 V) 1, 3 0 V 0.1 V 10 V Current output 1 4 mA 4.16 mA 20 mA Models Minimum value of rated flow range *4 Maximum value of rated flow range PF3A701H 10 L

V) 1 0 V 0.10 V 10 V 1: The analogue output current from the connected equipment should be 20 A or less when selecting 0 to 10 V.

Cushion NCA D-X Mounting 20Standard Stroke Data Bore size (in) 1.50 2, 2.50 3.25, 4 Standard stroke 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20, 24 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20, 24, 28 Smooth movements even at 0.4 to 2 inch/sec Auto switch mounting available.

, 12, 14, 16, 18, 20 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20, 24 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20, 24, 28 Example: NCDA1B150-0200R+0300-XC11 will stroke 2" then an additional 3" for a total stroke of 5".

Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specifications: DS (Out: NPN; Func: Analog Current Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector)

Rated Flow Range: 30 to 3000 l/min, Thread Type: NPT, Port Size: 1, Output Specifications: Out: NPN; Func: Analog Current Output <-> External Input, Lead Wire: w/o Lead Wire and M12 Connector, Unit Specification: -, Calibration Certificate: -

Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specifications: DS (Out: NPN; Func: Analog Current Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: M (SI Unit Only)

Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specifications: DS (Out: NPN; Func: Analog Current Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: M (SI Unit Only), Calibration Certificate: A (Made to Order)

Rated Flow Range: 30 to 3000 l/min, Thread Type: NPT, Port Size: 1, Output Specifications: Out: NPN; Func: Analog Current Output <-> External Input, Lead Wire: w/o Lead Wire and M12 Connector, Unit Specification: SI Unit Only, Calibration Certificate: -

Rated Flow Range: 30 to 3000 l/min, Thread Type: NPT, Port Size: 1, Output Specifications: Out: NPN; Func: Analog Current Output <-> External Input, Lead Wire: w/o Lead Wire and M12 Connector, Unit Specification: SI Unit Only, Calibration Certificate: Made to Order

Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: Rc, Port Size: 10 (1), Output Specifications: FS (Out: PNP; Func: Analog Current Output <-> External Input)

Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: Rc, Port Size: 10 (1), Output Specifications: DS (Out: NPN; Func: Analog Current Output <-> External Input)

Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: Rc, Port Size: 10 (1), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input)

Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: Rc, Port Size: 10 (1), Output Specifications: CS (Out: NPN; Func: Analog Voltage Output <-> External Input)

Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: Rc, Port Size: 10 (1), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector)

Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: Rc, Port Size: 10 (1), Output Specifications: CS (Out: NPN; Func: Analog Voltage Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector)