Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: F [G (ISO 1179-1 Compliant)], Port Size: 14 (1 1/2), Output Specifications: FS (Out: PNP; Func: Analog Current Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: M (SI Unit Only)
Rated Flow Range: 60 to 6000 l/min, Thread Type: F [G (ISO 1179-1 Compliant)], Port Size: 1 1/2, Output Specifications: Out: PNP; Func: Analog Current Output <-> External Input, Lead Wire: w/o Lead Wire and M12 Connector, Unit Specification: SI Unit Only, Calibration Certificate: -
A G E G A S K E T: N I P P L E: M-3N M-5N U N I V E R S A L T E E: M-3UT M-5UT P L U G: M-3P M-5P M-5G1 M-3G P R O D U C T S E L E C T O R P R O D U C T S E L E C T O R P R O D U C T S E L E C T O R P R O D U C T S E L E C T O R P R O D U C T S E L E C T O R E L B O W: M-5L G A S K E T: M-5GH T E E: M-5T H O S E N I P P L E: M-5H-4 M-5H-6 H O S E E L B O W: M-5HL-4 M-5HL-6 Similar to Picture
B O L S ADH4 00 04 T H R E A D .Rc(PT) N .NPT M A X.
[F 5] [ FnC] Select FUNC (switching Analogue output 2/ External input) [ oUt] Analogue output PF3A706H Equivalent to M5 3 Nm10% 8 PF3A712H 9 Equivalent to M6 5.2 Nm10% : Arbitrary display mode can be added to the sub display by setting the [F10] sub display.
(For accumulated increment) [H_1 ] Setting of Hysteresis [ 300] 300 L/min (PF3A706H) Do not use the product in a place where static electricity is a problem. Otherwise it can cause failure or malfunction of the system.
Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: N (NPT), Port Size: 14 (1 1/2), Output Specifications: DS (Out: NPN; Func: Analog Current Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: M (SI Unit Only)
Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: N (NPT), Port Size: 14 (1 1/2), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: M (SI Unit Only)
Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: N (NPT), Port Size: 14 (1 1/2), Output Specifications: FS (Out: PNP; Func: Analog Current Output <-> External Input), Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: M (SI Unit Only)
Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: N (NPT), Port Size: 14 (1 1/2), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input), Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: M (SI Unit Only)
Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: N (NPT), Port Size: 14 (1 1/2), Output Specifications: CS (Out: NPN; Func: Analog Voltage Output <-> External Input), Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: M (SI Unit Only)
Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: N (NPT), Port Size: 14 (1 1/2), Output Specifications: DS (Out: NPN; Func: Analog Current Output <-> External Input), Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: M (SI Unit Only)
Rated Flow Range: 60 to 6000 l/min, Thread Type: NPT, Port Size: 1 1/2, Output Specifications: Out: NPN; Func: Analog Current Output <-> External Input, Lead Wire: w/o Lead Wire and M12 Connector, Unit Specification: SI Unit Only, Calibration Certificate: -
Rated Flow Range: 60 to 6000 l/min, Thread Type: NPT, Port Size: 1 1/2, Output Specifications: Out: PNP; Func: Analog Voltage Ouput <-> External Input, Lead Wire: w/o Lead Wire and M12 Connector, Unit Specification: SI Unit Only, Calibration Certificate: -
Rated Flow Range: 60 to 6000 l/min, Thread Type: NPT, Port Size: 1 1/2, Output Specifications: Out: PNP; Func: Analog Current Output <-> External Input, Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: SI Unit Only, Calibration Certificate: -
Rated Flow Range: 60 to 6000 l/min, Thread Type: NPT, Port Size: 1 1/2, Output Specifications: Out: PNP; Func: Analog Voltage Ouput <-> External Input, Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: SI Unit Only, Calibration Certificate: -
Rated Flow Range: 60 to 6000 l/min, Thread Type: NPT, Port Size: 1 1/2, Output Specifications: Out: NPN; Func: Analog Voltage Output <-> External Input, Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: SI Unit Only, Calibration Certificate: -
Rated Flow Range: 60 to 6000 l/min, Thread Type: NPT, Port Size: 1 1/2, Output Specifications: Out: NPN; Func: Analog Current Output <-> External Input, Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: SI Unit Only, Calibration Certificate: -
Rated Flow Range: 60 to 6000 l/min, Thread Type: NPT, Port Size: 1 1/2, Output Specification: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: w/o Lead Wire and M12 Connector, Unit Specification: SI Unit Only, Calibration Certificate: -
Rated Flow Range: 60 to 6000 l/min, Thread Type: NPT, Port Size: 1 1/2, Output Specification: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: Lead Wire and M12-M12 Connector, 3m, Unit Specification: SI Unit Only, Calibration Certificate: -