SMC Corporation of America
Elite Part Number Search
Search Results "PF3W520-N04-1-A"

Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: NPT, Port Size: 1/2, Output Specification/Temperature Sensor: Out 1 Flow Rate: Analog 1 to 5 V; Out 2 Temperature: None; Temperature Sensor: None, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min, Temperature: °C, Bracket: None, Calibration Certificate: w/

Designed to work with fluids up to 90ºC, these switches incorporate a built-in temperature sensor so both flow and fluid temperature can be effectively monitored at the same time. 

N M8 M8 R / ZS-40-K PF3W504/520 4 3X8 ZS-40-L PF3W540 4 3X8 ZS-40-M PF3W511 4 4X10 M8 ZS-40-A 3 m 2 250 L/min PVC 25 A ZS-40-U25 25 A PVC 1 PVC 30 A ZS-40-U30 30 A PVC 1 25 A ZS-40-U25-A 1 M5x80 2 30 A ZS-40-U30-A 1 M5x65 2 PVC 1~2% -13No.PF-OMN0009CN-F FLOW POWER (OUT ) M8 1 DC+ (4 ) () 2 NC/ () () 3 DC() 4 (IN ) () M8 IN OUT POWER FLOW POWER FLOW -14No.PF-OMN0009CN-F

For example, when analogue output is 1 to 5 V, F.S. = 5[V] 1[V] = 4[V], (ref. 1%F.S. = 4[V] x 1% = 0.04[V]) F.S. (Full span, Full scale) H A function to store the accumulated flow value in the products internal memory. The flow value will be stored at a set time interval of either 2 or 5 minutes.

Accumulated pulse output A type of output where a pulse is generated every time a predefined accumulated flow passes. It is possible to calculate the total accumulated flow by counting the pulses. Outputs a value proportional to the flow rate. When the analogue output is in the range 1 to 5 V, it will vary between 1 to 5 V according to the rate of flow.

Type Symbol sensor Flow rate Flow rate Temp. 1 Analogue 1 to 5 V None 2 Analogue 4 to 20 mA Remote sensor 1T Analogue 1 to 5 V Analogue 1 to 5 V With temp. sensor 2T 1 Analogue 4 to 20 mA Analogue 4 to 20 mA A NPN NPN B PNP PNP C NPN Analogue 1 to 5 V D NPN Analogue 4 to 20 mA None E PNP Analogue 1 to 5 V F PNP Analogue 4 to 20 mA G 1 NPN External input 2 Integrated display type H 1 PNP External

rate) M For Digital Flow Switch for Water / PF3W511 B A B PF3W504 0 4 PF3W520 0 16 PF3W540 0 40 PF3W511 0 100 Display A Set A and B to the values shown in the table on the left.

RoHS 50 g 100 g 1OFF (2 5 ) 5 100 (24 5 min100 500 min9.5 ) 290(7 s) 390(7 s) -67No.PF-OMN0011CN-C 0100 1 / -10110 1 3F.S. 7 s 2 5F.S. 1090 2 (ZS-40-W) AWG26 0.51 mm 1.00 mm 3.5 mm -68No.PF-OMN0011CN-C / (PF3W704/720740) A B C 1 V 1.5 V 5 V 4 mA 6 mA 20 mA (PF3W711) A B C 1 V 1.4 V 5 V 4 mA 5.6 mA 20 mA (PF3W721) A B C 1 V 1.5 V 5 V 4 mA 5.9 mA 20 mA [L/min] PF3W504 0.5

Upper 3 digits Lower 3 digits Reverse output Warning: + ON Time Part A should then be pressed in using a suitable tool, such as pliers. 2 sec. OFF Initialize mode DANGER indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.

Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 04 (1/2), Output Specification: 1 (OUT1: Analog 1 to 5V)

Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1/2, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: -, Lead Wire: -, Units on Label: -, Bracket: -, Calibration Certificate: -, Made to Order: -

D2 D3 L1 L2 L3 L4 M1 L5 Weight T D1 H(1) D2 D3 L1 L2 L3 L4 M1 L5 H(1) A(2) A(2) AQ Weight (g) (g) Model Min.

M5 Port size With One-touch fitting M5 x 0.8 R 1/8 R 1/4 R 3/8 R 1/2 10-32UNF NPT1/8 NPT1/4 NPT3/8 NPT1/2 01 02 03 04 U10/32 N01 N02 N03 N04 SMC Pneumatics, Inc. 5 Series ASIII1F-T Dimensions (mm) 1in=25.4mm L5 D3 Elbow type H (width across flats) Applicable tubing O.D. d A L4 D1 L3 M1 D2 T L1 L2 Metric sizes Inch sizes d T H D1 D2 D3 L1 L2 L3 L4 L5 A M1 Model A D1 Model T H D2 D3 L1 L2 L3

A (1) (2) L4 (1) (2) Mass (g) Model M1 D1 D2 L1 L2 L3 d T H Min.