SMC Corporation of America
Elite Part Number Search
Search Results "PF3WB08DN-P720W-04-FT-M"

B O L S ADH4 00 04 T H R E A D .Rc(PT) N .NPT M A X.

B C d H Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com MQ10-M MQ16-M MQ20-M MQ25-M MQ28-M NTJ-015A NT-015A NT-02 NT-03 NT-04 10 8 9.2 6 15.5 5 10 9.2 M5 x 0.8 4 20.5 8 16 8 9.2 8 16.5 6 16 11.5 M6 x 1.0 5 22.5 10 20 8 9.2 10 18.5 6 20 15 M8 x 1.25 5 24.5 13 25 10

Table 1 Display Real-time flow rate l/min Accumulated flow l, m, m x 10 ft, ft x 10, ft x 10 CFM Note 1) For the type with unit switching function [The type without the unit switching function will have a fixed SI unit (l/min, or l, m or m x 10)]. 98 &RXUWHV\RI6WHYHQ(QJLQHHULQJ,QF5\DQ:D\6RXWK6DQ)UDQFLVFR&$ *HQHUDO For Air Digital Flow Switch Series PFA 4.

CHQB100 10D (M) CH QB40 5D (M) 15D (M) 10D (M) 20D (M) 15D (M) x 90l x 95l x 100l x 105l x 110l x 115l x 120l x 145l x 170l 25D (M) 20D (M) 30D (M) 25D (M) 35D (M) 30D (M) 13.5 10 40D (M) 35D (M) 45D (M) 40D (M) 50D (M) 45D (M) 75D (M) 50D (M) x 195l 100 (M) 75D (M) 100D (M) M6 x 90l x 95l x 100l x 105l x 110l x 115l x 120l x 125l x 130l x 155l CH QB50 10D (M) 15D (M) 20D (M) 25D (M) 30D

20 ~ 600 32 35 81 70 52 20 40 10 17 17 M 8 x 1.25 7 M 18 x 1.5 30 3/8 90 0 63 ~ 600 20 ~ 600 32 35 101 85 64 20 40 10 17 17 M 10 x 1.25 7 M 18 x 1.5 31 3/8 98 0 80 ~ 750 20 ~ 750 37 40 119 102 78 25 52 14 21 21 M 12 x 1.75 11 M 22 x 1.5 37 1/2 116 0 100 ~ 750 20 ~ 750 37 40 133 116 92 30 52 14 21 21 M 12 x 1.75 11 M 26 x 1.5 40 1/2 126 0 Without gaiter With gaiter Bore Size (mm) FV FD FT

1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ None N (Example) H7CN Solid state auto switches marked with are produced upon receipt of order.

Lead wire length symbols: 0.5 m Nil (Example) A54 3 m L (Example) A54L 5 m Z (Example) A54Z In addition to the models in the above table, there are some other auto switches that are applicable.

Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min

Valve; w/Stop Valve, Supply/Return Port Size: 3/8, Return Unit Flow Switch Output Specifications: Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated

Applicable thread Gasket M-3G2 M3 M-5G2 M5 M-6G M6 Brass Description Part no.

Bore size (mm) Dd9 L l m d Part no.

Lead wire length symbols: 0.5 m Nil (Example) M9NW Solid state auto switches marked are produced upon receipt of order. Auto switch models D-A9 and D-APV cannot be mounted on CHD2E, CHD2H of all bore sizes and CHD2F32. 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Since there are applicable auto switches other than listed, refer to page 380 for details.

Electrical entry Grommet L plug connector M plug connector DIN terminal G L M D Applicable Auto Switch/Refer to page 10-20-1 for further information on auto switches.

(mm) L L Dd9 d l l d m t Used snap ring t m Used snap ring Part No.

8 -04 R 1/2 -04 R 1/2 Straight Union KGH KGLU12-02 R 1/4 12 -03 R 3/8 -04 R 1/2 Applicable tubing O.D.