Your search for PFM returned 30 result(s)
There were no hits with the full part number, but there were 13 hits in the keyword search.
There were no hits with the full part number, but there were 9 hits in the keyword search.
Product Information » New Products Search Results
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: R (Bracket for w/o Flow Adjustment Valve: ZS-33-M)
(MPa): 1, Flow Rate Type: Standard, Operating Temperature Range(°C): -10~60, Operating Humidity Range(%): 35~85, Number of Inputs: 2, Number of Outputs: 1, Analog Voltage Output(V): [DC1-5V] 1-5V, Power Supply Type: DC, Power Supply Voltage(V): [24] 24±10%, Pipe Connection Direction: 2-way, Connecting Tube Diameter: -, Liquid contact parts material: Resin + Metal, Mounting Hole: Presence,
or 2s can be chosen., Easy connection and removal of wiring., IFW/PFW 1/8INCH PT VERSION, INSTRUMENTATION, IFW/PFW FLOW SWITCH, CB, IFW/PFW 1/8INCH PT VERSION, 0.88184 lb, ModelPort sizeMaterialSensor cableMassWith sensor cableWithout sensor cable01R 1/8M5 x 0.8Case: C3604 + nickel plated, Piping port/pressure sensor: Stainless steel 316LPSE56 - : Oil proof heavy-duty vinyl cable
To obtain more detailed information about operating this product, please refer to the SMC website (URL http://www.smcworld.com) or contact SMC directly. approx. 1 second The flow range is displayed 10 L/min (PFM510) 25 L/min (PFM525) 50 L/min (PFM550) 100 L/min (PFM511) Indicator LED (OUT2) Indicates the output status of OUT2. LED is ON (Red) when OUT2 is ON.
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: W [Lead Wire w/Connector (2m) + Rubber Cover]
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: -
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)]
(MPa): 1, Flow Rate Type: Standard, Operating Temperature Range(°C): -10~60, Operating Humidity Range(%): 35~85, Number of Inputs: 2, Number of Outputs: 1, Analog Voltage Output(V): [DC1-5V] 1-5V, Power Supply Type: DC, Power Supply Voltage(V): [24] 24±10%, Pipe Connection Direction: 2-way, Connecting Tube Diameter: -, Liquid contact parts material: Resin + Metal, Mounting Hole: Presence,
Series: 25A-PFM5, Rated Flow Range: 10 [0.2 to 10 (5) L/min], Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Operation Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Lead Wire: W (w/Lead Wire w/Connector, Rubber Cover for Connector, Silicone Rubber)
Series: 25A-PFM5, Rated Flow Range: 10 [0.2 to 10 (5) L/min], Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Operation Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Lead Wire: w/Lead Wire w/Connector, Rubber Cover for Connector, Silicone Rubber
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate)
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: R (Bracket for w/o Flow Adjustment Valve: ZS-33-M)
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Z (w/o Lead Wire w/Connector)
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: T (Panel Mount Adapter for w/o Flow Adjustment Valve)
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: N (None)
(MPa): 1, Flow Rate Type: Standard, Operating Temperature Range(°C): -10~60, Operating Humidity Range(%): 35~85, Number of Inputs: 2, Number of Outputs: 1, Analog Voltage Output(V): [DC1-5V] 1-5V, Power Supply Type: DC, Power Supply Voltage(V): [24] 24±10%, Pipe Connection Direction: 2-way, Connecting Tube Diameter: -, Liquid contact parts material: Resin + Metal, Mounting Hole: Presence,