Measurement Flow Range: 30F (-3.0 to 3.0 â„“/min), Measurement Flow Range for X502: None, Instruction Manual: N (None), Option: A (w/L-Type Bracket/Mounting Screw)

Measurement Flow Range: -3.0 to 3.0 â„“/min, Measurement Flow Range for X502: None, Instruction Manual: None, Option: w/L-Type Bracket/Mounting Screw

Response speed: 5ms or less , Proof pressure: 500 kPa , Low flow rate range , Output: 1 to 5V analog (non-linear) , Piping specification: M5 female threads, Weight 10g (not including the lead wire), Flow Sensor for Air, DIGITAL FLOW SWITCH, 10 lb

(1 to 5 V) output type Max. 80 mA Internal voltage drop: 1 V or less Analogue output: 1 to 5 V Output impedance: approx. 1 k PFMV304 PNP (2 outputs) + Analogue (4 to 20 mA) output type Max. 80 mA Internal voltage drop: 1 V or less Analogue output: 4 to 20 mA Max. load impedance: 600 (24 VDC) PFMV305 PNP (2 outputs) + External input type Max. 80 mA Internal voltage drop: 1 V or less External

PF-OMK0003CN-E PFMV505(F)-1 PFMV510(F)-1 [kPa] [kPa] [L/min] [L/min] PFMV530(F)-1 [kPa] [L/min] -21No. PF-OMK0003CN-E PFMV5 PFMV5 + L (ZS-36-A) 10n +24(n=15) 10n +14 L L L -22No.

PFMV505 0.5 L 0 to 0.5 [L/min] PFMV530F -3.0 to 3.0 [L/min] -3.0 L Sensor connector PFMV510F -1.0 L -1.0 to 1.0 [L/min] WARNING indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury.

Measurement Flow Range: -3.0 to 3.0 â„“/min, Measurement Flow Range for X502: None, Instruction Manual: -, Option: -

Measurement Flow Range: 30F (-3.0 to 3.0 â„“/min), Measurement Flow Range for X502: None, Instruction Manual: w/Instruction Manual (Japanese/English), Option: A (w/L-Type Bracket/Mounting Screw)

Measurement Flow Range: -3.0 to 3.0 â„“/min, Measurement Flow Range for X502: None, Instruction Manual: w/Instruction Manual (Japanese/English), Option: w/L-Type Bracket/Mounting Screw

Response speed: 5ms or less , Proof pressure: 500 kPa , Low flow rate range , Output: 1 to 5V analog (non-linear) , Piping specification: M5 female threads, Weight 10g (not including the lead wire), FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, 2X, IFW/PFW NO SIZE ALL OTHER, .17762 lb

Response speed: 5ms or less , Proof pressure: 500 kPa , Low flow rate range , Output: 1 to 5V analog (non-linear) , Piping specification: M5 female threads, Weight 10g (not including the lead wire), FLOW SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, 2X, IFW/PFW NO SIZE ALL OTHER, .17288 lb

Measurement Flow Range: 05F (-0.5 to 0.5 â„“/min), Measurement Flow Range for X502: None, Instruction Manual: N (None)

Measurement Flow Range: 10 (0.0 to 1.0 â„“/min), Measurement Flow Range for X502: None, Instruction Manual: N (None)

Measurement Flow Range: 10F (-1.0 to 1.0 â„“/min), Measurement Flow Range for X502: None, Instruction Manual: N (None)