Magnet: Built-in, Mounting: B [Through Hole (Standard)], Bore Size: 32mm, Port Thread Type: Rc, Stroke: 75mm, Body Option: Rod End Male Threads, Locking Direction: Extension Locking, By-Pass Piping: w/By-Pass, Right-Hand Piping, Drop Prevention, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Bore Size: 32mm, Port Thread Type: Rc, Stroke: 75mm, Body Option: M (Rod End Male Threads), Locking Direction: F (Extension Locking), By-Pass Piping: R (w/By-Pass, Right-Hand Piping, Drop Prevention), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal
Magnet: Built-in, Mounting: B [Through Hole (Standard)], Bore Size: 32mm, Port Thread Type: Rc, Stroke: 75mm, Body Option: Rod End Male Threads, Locking Direction: Extension Locking, By-Pass Piping: w/By-Pass, Right-Hand Piping, Drop Prevention, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: -, Number: -
Series RLQ is a compact cylinder with a built-in lock and air cushion. Should the air supply be cut off, the RLQ was designed by SMC to provide the safety of drop prevention at any point of the stroke. Additional features include standardized bypass piping, and a home position holding function. The RLQ is the perfect solution for applications which require larger kinetic energy, high
Series RLQ is a compact cylinder with a built-in lock and air cushion. Should the air supply be cut off, the RLQ was designed by SMC to provide the safety of drop prevention at any point of the stroke. Additional features include standardized bypass piping, and a home position holding function. The RLQ is the perfect solution for applications which require larger kinetic energy, high
Series RLQ is a compact cylinder with a built-in lock and air cushion. Should the air supply be cut off, the RLQ was designed by SMC to provide the safety of drop prevention at any point of the stroke. Additional features include standardized bypass piping, and a home position holding function. The RLQ is the perfect solution for applications which require larger kinetic energy, high
ID AMG Accessory (Option) HAA7 HAA7 HAA15 HAA22 HAA37 Auto-drain Applicable model AFF Working Principle HAA7-F HAA7-S HAA15-F AD402-03 HAA15-S HAA22-F HAA22-S HAA37-F AD402-04 Dust-protecting filter Mounting bench AM HAA37-S Inlet side air (HOT AIR) Push button switch Pilot light The accessories should be mounted by user. Misc.
flats 17 Purge air discharge tubing port for dehumidification Applicable tube O.D.: 12 (NPT threads: 1/2 inch) Applicable tube O.D.: 10 (NPT threads: 3/8 inch) 26 Series IDG Membrane Air Dryer Dimensions (mm) (M Type) 1in = 25.4mm , , IDG60HM, 75HM, 100HM IDG60M, 75M, 100M (A) (B) Port size D (C) L Purge air for dew point indicator M J K N H G 37 22 18 OUT IN (F) (E) (352) Purge air for
Note 2) They are not applicable in case the thread type is N or F.
PP depth element Nominal filtration accuracy: 1 to 75m Material: PP EJ202S ... x 11 (L125) EJ302S ... x 11 (L250) EJ402S ... x 11 (L500) b Set the stopper on the retainer while holding down the V-band outside perimeter, and then tighten the wing bolt to the prescribed position.
PP depth element Nominal filtration accuracy: 1 to 75m Material: PP EJ202S ... x 11 (L125) EJ302S ... x 11 (L250) EJ402S ... x 11 (L500) b Set the stopper on the retainer while holding down the V-band outside perimeter, and then tighten the wing bolt to the prescribed position.
Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Bore Size: 32mm, Port Thread Type: Rc, Stroke: 75mm, Body Option: M (Rod End Male Threads), Locking Direction: B (Retraction Locking)
Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Bore Size: 32mm, Port Thread Type: Rc, Stroke: 75mm, Body Option: M (Rod End Male Threads), Locking Direction: B (Retraction Locking), By-Pass Piping: None (Emergency Stop), Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector), Number
LECYU uses the MECHATROLINK-III protocol, connecting up to 62 units at a max distance of 75m between units, with 100 Mbps transmission speed. Synchronous motion control is possible with additional equipment.
LECYU uses the MECHATROLINK-III protocol, connecting up to 62 units at a max distance of 75m between units, with 100 Mbps transmission speed. Synchronous motion control is possible with additional equipment.
Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Bore Size: 32mm, Port Thread Type: Rc, Stroke: 100mm, Body Option: M (Rod End Male Threads), Locking Direction: F (Extension Locking)
Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Bore Size: 32mm, Port Thread Type: Rc, Stroke: 25mm, Body Option: Rod End Female Threads, Standard, Locking Direction: F (Extension Locking)
Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Bore Size: 32mm, Port Thread Type: Rc, Stroke: 75mm, Body Option: Rod End Female Threads, Standard, Locking Direction: F (Extension Locking)
Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Bore Size: 32mm, Port Thread Type: Rc, Stroke: 20mm, Body Option: M (Rod End Male Threads), Locking Direction: F (Extension Locking)
Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Bore Size: 32mm, Port Thread Type: Rc, Stroke: 40mm, Body Option: M (Rod End Male Threads), Locking Direction: F (Extension Locking)