Model: SGC200, Valve Type: Normally Closed, Seal Material: FKM, Pressure Range: 0 to 0.5 MPa, Thread: Rc, Port Size: 1/2, Pilot Valve: 0.35 W Type, V116, Voltage: 24 VDC, Electrical Entry: DIN Terminal, Surge Suppressor: With Light and Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Bracket Mounting Position: Bracket on the Left Side, Auto Switch: -, Lead Wire: -, Number
Applicable bore size B1 C1 d H1 Part no. Applicable bore size B2 C2 d H2 CK1 SNJ-006B 6 8 9.2 M6 x 1.0 4 NTJ-006A 6 5.5 6.4 M3 x 0.5 2.4 Y-J016C 16 11 16.6 21 M5 x 0.8 SNJ-010C 10 11 12.7 M8 x 1.0 4 NTJ-010C 10 7 8.1 M4 x 0.7 3.2 Part no.
GR GL LOCK FREE PL PG P (Rc, NPT) Head side cylinder port Width across flats KA 4 x J PW GB PH 2 x Cushion valve Width across flats B1 MM LZ D E C B F H1 C M N BN AL B K A S + Stroke M H ZZ + Stroke With rod boot l 10.2 h + l ZZ + l + Stroke [mm] Bore size [mm] Stroke range [mm] A AL B B1 BN BP BQ C D E F GA GB GC GD GL GR H1 J Without rod boot With rod boot 40 Up to 500 20 to 500 30 27
With Air Cushion/Basic: CLG1BA Bore (mm) Stroke range A B1 BC BN BZ C D E GA GB GC GD GK GL GQ GR I J K KA MM NA AL 20 25 32 40 to 200 to 300 to 300 to 300 15.5 19.5 19.5 27 18 22 22 30 13 17 17 19 57.5 69 69 76 8 10 12 16 M4 X 0.7 depth 7 M5 X 0.8 depth 5 M5 X 0.8 depth 8 M6 X 1 depth 12 5 5.5 5.5 6 10 14 24 29 35.5 44 12 14 18 25 14 16.5 20 26 38 45 45 52 M8 X 1.25 M10 X 1.25 M10 X 1.25
GL1 T Q Rc P Head side cylinder port 4-J Width across flats KA 4-FD GB With rod boot Width across flats B1 MM W B E D FY FV BF e H1 V AL 8 f l K A C h + l BN N F FX ZZ + l + Stroke FT S + Stroke ZZ + Stroke H FZ Bore size (mm) Stroke range (mm) 40 50 63 80 100 A AL B B1 BF BN BP BQ C D E F FD FT FV FX FY FZ GA GB GC GD GL GL1 GR H1 30 27 60 22 71 96 1/8 1/8 44 16 32 10 9 12 60 80 42 100
GL GR D E MLGC Q T H1 AL A H S + Stroke ZZ + Stroke CNG N K F M M BN W V MNB Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com C B CNA CNS With rod boot CLS CLQ e MLGP 8 f l RLQ ZZ + l + Stroke h + l MLU ML1C DBore size (mm) Stroke range (mm) A AL B B1 BN BP BQ C D
MB, MB1 series MM Cushion valve W Width across flats Width across flats B1 E D H1 Effective thread Effective thread length Width across flats Bore size (mm) A B1 D H H1 K MM W ZZ A K 32 40 50 63 80 100 H 30 27 16 51 8 6 14 M14 x 1.5 7.2 139 22 ZZ + Stroke 35 32 20 58 11 7 18 M18 x 1.5 9.7 146 27 40 37 25 68 13 10 22 M22 x 1.5 10.5 166 32 40 37 25 68 13 10 22 M22 x 1.5 12 166 32 40 37 30 74
W GL1 GE B B2 C H S + Stroke Width across flats B1 A F GB K BN GF Cushion valve 2-J (Both sides) Rc P MM Effective thread length Head side cylinder port H1 Q E D V LY 4-LD LH Width across flats Y X X Y N T LX VA LT LS + Stroke ZZ + Stroke LZ Width across flats Bore size (mm) Stroke range (mm) Effective thread length (mm) Ee11 GA GB GC GD GL GL1 B B1 A H1 B2 BN BP C D F GR GE GF 32 54 97
LS + Stroke ZZ + Stroke LZ Width across flats Bore size (mm) Stroke range (mm) Effective thread length (mm) Ee11 GA GB GC GD GL GL1 B B1 A H1 B2 BN BP C D F GR GE GF 32 54 97 46 6 13 32.5 1/8 Up to 700 30 13 18.3 10 4 8.5 45.5 22 17 12 13 88.5 83 12 19.5 40 63 104 52 8 16.5 38 1/8 Up to 800 35 14 19.5 14 4 10 52.5 30 22 16 13 96.5 91 12 27 50 75 120.5 65 11 19 46.5 1/4 Up to 1000 40 15.5
Head side cylinder port Rc P S + Stroke ZZ + Stroke Boss-cut With rod boot e ZZ + Stroke 9 9 l f h A BP D E BZ GA H2 I H1 AL B2 B1 BN BC F BQ 1/8 1/8 1/8 1/8 GC GB GK GD GQ GL H GR Bore (mm) Stroke range 0 0.033 0 0.033 0 0.033 0 0.039 1/8 1/8 1/8 1/8 8 20 20 8 80 18 55 13 26 5 57.5 73.5 15.5 3.5 38 6 13 8 28 8 4 41 4 Up to 300 10 25 26 8 90 19.5 22 64.5 17 32 6 69 83.5 4 45 9 13 8 33.5
flats B1 PH MM 0 0.05 E 0 0.05 BZ D E BC I H1 4-TC TB TA AL A F K 0. 1 C0. 1 C 8-J BN BC NA S + Stroke H ZZ + Stroke F e f 8 l ZZ + l + Stroke h + l With rod boot (mm) Bore size (mm) Stroke range without rod boot Standard Long stroke 20 25 32 40 Stroke range with rod boot Standard Long stroke A AL B1 BC BN BP BZ C D E F GA GB GC GK GL GR GQ H1 I 10 (12) 6 201 to 350 20 to 200 4 to 200 38
BC PH MM H1 PD E 0 0.05 E 0 0.05 I BZ TH Width across flats B1 Width across flats KA Width across flats NA 8-J TT TY TW C0. 1 TX TE +0.10 0 4-TF TV TZ BC Z ZZ + Stroke f 8 l e h + l ZZ + l + Stroke Z + l With rod boot (mm) Bore size (mm) Stroke range without rod boot Standard Long stroke 20 25 32 40 Stroke range with rod boot Standard Long stroke A AL B1 BC BN BP BZ C D E F GA GB GC GK GL
Head side cylinder port Rc P Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com S + Stroke ZZ + Stroke Boss-cut With rod boot e ZZ + Stroke 9 9 l f h A BP D E BZ GA H2 I H1 AL B2 B1 BN BC F BQ 1/8 1/8 1/8 1/8 GC GB GK GD GQ GL H GR Bore (mm) Stroke range 0 0.033
Applicable bore size (mm) B1 C D d H1 Applicable snap ring Applicable snap ring t m Part no.
Note 2) Combination with option B or option B1 is not necessary. The earth leakage breaker with a handle (Option B1) is provided as standard.
A specified earth leakage breaker is installed for option B, option B1, option S of each model. If the product is not option B, option B1, option S, please prepare an earth leakage breaker on the users side. A specified earth leakage breaker and handle are installed for HRSH--40*2.
A 20 HRS Options Cooling capacity None Nill 100 10kW Castersadjuster foots A 150 15kW Earth leakage breaker B Earth leakage breaker B1 with a handle B1 Cooling method Fluid fill port K A Air-cooled refrigeration W Water-cooled Fixed SI unit W refrigeration *1 : In case of power supply '40/46', this is standard.