+ 152 + 47 x n2 L2 = 10.5 x n1 + 42 L4 = L3 10.5 L5 = (L3 L1)/2 L6 = 47 x n2 + 82 Note 1) These figures show the SS5Y3-10S6Q32-05D-C6.

EX260 Serial transmission Calculation of dimensions L1 = 12.5 x n1 + 16 x n2 + 88.7 L2 = 12.5 x n1 + 16 x n2 + 48 M = L1/12.5 + 1 Remove all numbers after the decimal.

A COM (Red) Black 5B Station 6 11A 11B 12A 12B COM Red 13A Red (COM) Red (COM) 13A 13B COM Manifold specification example Red 13B Stations 1 The drawing above shows connections for type 26P flat ribbon cable connector based on the manifold specification example in the table to the left.

C10: 10 (SMC) C12: 12 (SMC) L1 = 16 x n1 + 147 + 47 x n2 L2 = 16 x n1 + 53.5 L4 = L3 10.5 L5 = (L3 L1) / 2 L6 = 47 x n2 + 81.5 * These figures show the JJ5SY5-10S6Q22-05D-C12. * Refer to page 99 for dimensions of external pilot (Made to Order) and silencer. n1: Valve stations n2: I/O unit stations L3: DIN Rail Overall Length Valve stations (n1) I/O unit stations (n2) 2 3 4 5 6 7 8 9 10

A 5B 3 stations White 6A 6B Black 7A 7B 4 stations White 8A 8B How to Increase Manifold Stations Black 9A 9B 5 stations White 10A 10B 5B SOL.A COM (Red) Black 6 stations 11A 11B 12A 12B Construction COM. 13A Red COM (Red) COM (Red) 13A 13B Manifold Specifications Example Red 13B COM.

A B Note) DXT060-51-13B, DXT152-14-1B are for energizing continuously.

Size Inch Size Applicable tubing O.D. inch Model D1 D2 L Weight g Applicable tubing O.D. inch Model D1 D2 L Weight g 1/8 KQ2C-01A 7.3 4.3 2.6 0.1 3/16 KQ2C-05A 9 5.9 2.6 0.1 1/4 KQ2C-07A 10.7 7.5 2.6 0.1 3/8 KQ2C-11A 14.8 10.7 2.7 0.1 1/2 KQ2C-13A 18.5 13.9 2.7 0.1 1/8 KQ2C-01A 7.3 4.3 2.6 0.1 3/16 KQ2C-05A 9 5.9 2.6 0.1 1/4 KQ2C-07B 11.5 7.5 2.6 0.1 3/8 KQ2C-11B 15.7 10.7 2.7 0.1 1/2 KQ2C-13B

O.D.: 4, 5/32" 6, 1/4" Note) The L1 to L4 dimensions of SS5Y3-45FUC4, N3 C6, N7 C4, N3 C6, N7 Stations Uare identical to those of SS5Y3-45FUStations D.

EX260 Serial transmission Calculation of dimensions L1 = 12.5 x n1 + 16 x n2 + 88.7 L2 = 12.5 x n1 + 16 x n2 + 48 M = L1/12.5 + 1 Remove all numbers after the decimal.

EX260 Serial transmission Calculation of dimensions L1 = 12.5 x n1 + 16 x n2 + 88.7 L2 = 12.5 x n1 + 16 x n2 + 48 M = L1/12.5 + 1 Remove all numbers after the decimal.

, N3 <4(A), 2(B) port> C2: 2 One-touch fitting C3: 3.2 One-touch fitting C4: 4 One-touch fitting N1: 1/8" One-touch fitting N3: 5/32" One-touch fitting DIN rail clamping screw L2 = L1 10.5 L3 = 8.5 x n1 + 46 L4 = L3 + 81 + 47 x n2 L5 = (L1 L4)/2 L6 = 8.5 x n1 + 31 L7 = 47 x n2 + 86.1 (mm) L1: DIN Rail Overall Length Valve stations (n1) I/O Unit stations (n2) 1 2 3 4 5 6 7 8 9 10 11 12 13

EX260 Serial transmission Calculation of dimensions L1 = 12.5 x n1 + 16 x n2 + 88.7 L2 = 12.5 x n1 + 16 x n2 + 48 M = L1/12.5 + 1 Remove all numbers after the decimal.

+ 152 + 47 x n2 L2 = 10.5 x n1 + 42 L4 = L3 10.5 L5 = (L3 L1)/2 L6 = 47 x n2 + 82 Note 1) These figures show the SS5Y3-10S6Q32-05D-C6.

A A A Manual override 15 77.5 SS5Y3-45-D .

L1 to L4 of C4 C6 SS5Y3-45S2DStations D-Q, C4 C6 C4 C6 SS5Y3-45S2UStations D-Q, and SS5Y3-45S2UStations U-Q are the same as SV C4 C6 SS5Y3-45S2DStations U-Q.

-10B: ZP3-13B: ZP3-16B: P.52 ZP3B-Y2BK6-B5 Mounting Adapter Part No.