Your search for SYJ3000 returned 22 result(s)
There were no hits with the full part number, but there were 23 hits in the keyword search.
There were no hits with the full part number, but there were 6 hits in the keyword search.
Product Information » New Products Search Results
1.5 7 18 15.5 14.5 1.4 1.4 3.2 M3x0.5 KJF23-M3 7 7 18.5 6 14.5 3/2.5 2.6 3.2 M5x0.8 KJS23-M5 2 7 21.5 18 14.5 2.5 2.9 3.2 M5x0.8 KJF23-M5 7 7 21 7.5 14.5 3/2.5 2.9 4 M3x0.5 KJS04-M3 1.5 8 18 15.5 14.5 1.4 1.5 4 M3x0.5 KJF04-M3 8 8 18 5.5 14.5 4 3.2 4 M5x0.8 KJS04-M5 2.5 8 20.5 17 14.5 4 2.6 4 M5x0.8 KJF04-M5 8 8 20.5 7.5 14.5 4 3.8 4 R(PT)1/8 KJS04-01S 3 9.8 21.5 17.5 14.5 4 5.3 6 M5x0.8
2.a VALVES VALVES SERIES PAGE NUMBER SX3000 / SX5000 2.1 SOLENOID VALVE SY100 2.5 3/2 DIRECT ACTING / SOLENOID SPRING VALVE M3 PORTED SY3000/5000/7000 2.8 BODY PORTED SOLENOID VALVE SY3000/5000/7000 2.13 BASE MOUNTED SOLENOID VALVE VQ100 2.19 3/2 DIRECT ACTING / SOLENOID SPRING VALVE M3-M5 PORTED VQ0 2.21 5 PORT METAL/RUBBER SEAL ULTRA HIGH SPEED SOLENOID VALVE VQ1000 2.26 5 PORT METAL/RUBBER
x 0.35 x 19 M3 x 0.35 x 23 M3 x 0.35 x 24 M3 x 0.35 x 28 M3 x 0.35 x 68 M3 x 0.35 x 72 M3 x 0.35 x 73 M3 x 0.35 x 77 y u Components Ejector unit + Vacuum switch/Filter unit i o For nozzle size 10, 13, 15 M3 x 0.35 x 84 4 [For ZSE4 spec.]
Standard Specifications Standard Specifications Type of seal Metal seal Rubber seal Fluid Air, Inert gas Air, Inert gas Max. operating pressure 100 psi (0.7MPa) High pressure type 113 psi (0.8MPa) Min. operating pressure 14 psi (0.1MPa) 21 psi (0.15MPa) Valve specifications Solenoid specifications Note 1) Note 1) Ambient and fluid temperature 14 to 122F 14 to 122F Max. operating frequency 20Hz 5Hz
(Panel adaptor A + Panel adaptor B + Mounting bracket) ZS-22-D (With 4 pcs. of M3 tapping screws) ZS-22-E Panel adaptor A ZS-22-03 Panel adaptor B ZS-22-02 Mounting bracket ..
How to Order Valve T 5M N7 VQZ2120 SY Example/Valve C6 5M VQZ2120R SYJ External pilot specification Thread (Cylinder ports and P, R ports) SX VK Rc(PT) External pilot port N NPT VZ M3 x 0.5 (VQZ2000) M5 x 0.8 (VQZ3000) T NPTF F G(PF) VF Note) R port of VQZ2000 is only G(PF) 1/16 VFR Cylinder ports VP7 Symbol M5 02 N1 N3 N7 N9 N11 Applicable tube O.D.
How to Order Valve T VQZ212 5M N7 Example/Valve VQZ212R 5M C6 External pilot specification Thread (Cylinder ports, and P/R ports) Rc(PT) N NPT External pilot port T NPTF M3 X 0.5 (VQZ200) M5 X 0.8 (VQZ300) F G(PF) Note) R port of VQZ200 is only PF 1/16 Cylinder ports Symbol M5 02 N1 N3 N7 N9 N11 3/8" 1/8" 5/32" 1/4" 5/16" M5 Tube O.D.
Specifications Metal seal Seal Rubber seal Air, lnert gas Fluid Air, lnert gas 0.7MPa (High pressure type: 1.0MPa) Max. operationg pressure 0.15MPa Single Double 2 position Min. operating pressure 0.1MPa only for VQZ3000, 3 position 0.15MPa Valve specifications 0.1MPa 3 position 0.2MPa (1) (1) 10 to 50C Ambient and fluid temperature 10 to 50C SY Single Double Max. operating frequency 20Hz 5Hz
Look up from the 5Hz switching cycle to find the intersection with SUP=0.35MPa. 2. From the point just found, draw a line to the Y-axis to find the air consumption. The result is approximately 9l/min (ANR). 1 0 2 3 4 5 6 7 8 9 10 Cycle (Hz) Caution 1. These flow rate characteristics are for fresh water (viscosity 1mPas, specific gravity 1.0). 2.
Recommended Valve PA3000 PA5000 VQZ140 (exhaust center) VQZ240 (exhaust center) Refer to page 21 for further details. 6 Series PA3000/5000 Performance Curves/Air Operated Type PA513 Flow rate characteristics PA313 Flow rate characteristics 50 50 Cycle 7Hz Cycle 5Hz Cycle 3Hz (no change when SUP=0.2, 0.3MPa) Cycle 7Hz Cycle 5Hz Cycle 3Hz (no change when SUP=0.2MPa) SUP=0.5MPa 40 40 SUP=0.5MPa
Recommended Valve PA3000 PA5000 VQZ140 (exhaust center) VQZ240 (exhaust center) Refer to page 21 for further details. 6 Series PA3000/5000 Performance Curves/Air Operated Type PA513 Flow rate characteristics PA313 Flow rate characteristics 50 50 Cycle 7Hz Cycle 5Hz Cycle 3Hz (no change when SUP=0.2, 0.3MPa) Cycle 7Hz Cycle 5Hz Cycle 3Hz (no change when SUP=0.2MPa) SUP=0.5MPa 40 40 SUP=0.5MPa
Clean room Assembled and double-packaged in clean-room environment Note) With 3/8" inlet/outlet tube: 1 to 12l * The values appearing in the above table are representative of use in a room temperature environment and with tap water. 3 Series PA3000 Performance Automatically operated type Air pilot actuation type * Solenoid valve switching cycle PA3313-m03: Flow rate characteristics (5Hz
Internal pilot: 1 to 5HZ and external pilot: 1 to 8Hz is reference. The charts on page 10 show the relation for the adjustment needle value and operation frequency. However, there is approx. 2Hz of variation depending on individuality. Operating conditions affect the operating frequency.
Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC24V, Specification: Standard, Valve Type: 5-Port Valve, Actuation: -, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 3-PositionExhaust Center, Pipe Port Type: M, Port Size: M3, Pressure Rating(MPa): 0.2 to 0.7, Driving Type: Pilot Type Spool, Pilot Air Supply: Internal, Seal Type