SMC Corporation of America
Elite Part Number Search
Search Results "SYJ512-SG-M5-F"

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

1.4 (PE port) L plug connector (L): SYJ52-L-M5 (-F) M plug connector (M): SYJ52-M-M5 (-F) DIN terminal (D): SYJ52-D-M5 (-F) M8 connector (MO): SYJ52-WO-M5 (-F) Applicable cable O.D. 3.5 to 7 Approx. 300 (Lead wire length) 60.9 28.1 [35.1] 53.4 Max. 10 74.6 42.1 12.7 M8 x 1 32.6 15.1 39.2 [46.2] Approx. 300 (Lead wire length) Pg7 65.5 [67.7] 75.5 55.7 [57.9] 64.6 57.2 50.7 34.7 8 9 8 9 8

1.4 (PE port) L plug connector (L): SYJ52-L-M5 (-F) M plug connector (M): SYJ52-M-M5 (-F) DIN terminal (D): SYJ52-D-M5 (-F) M8 connector (MO): SYJ52-WO-M5 (-F) Applicable cable O.D. 3.5 to 7 Approx. 300 (Lead wire length) 60.9 28.1 [35.1] 53.4 Max. 10 74.6 42.1 12.7 M8 x 1 32.6 15.1 39.2 [46.2] Approx. 300 (Lead wire length) Pg7 65.5 [67.7] 75.5 55.7 [57.9] 64.6 57.2 50.7 34.7 8 9 8 9 8

8.5 13 12.7 2-2.6 (For manifold mounting) 28.1 [35.1] (Light/surge voltage suppressor) 2-2.6 (For mounting) + 14.5 3 23 20 2.3 55.6 [57.8] 12.7 28.1 [35.1] 8 9 M5 x 0.8 (P, R port) 23 7 (Bracket) R P 11 11.5 1.4 (PE port) L plug connector (L): SYJ52-L-M5 (-F) M plug connector (M): SYJ52-M-M5 (-F) DIN terminal (D): SYJ52-D-M5 (-F) M8 connector (M0): SYJ52-W0-M5 (-F) Applicable cable O.D.

X 0.8 20 Type How to Order Applicable solenoid valve SYJ512-l-M5 SYJ512M-l-M5 SYJ522-l-M5 SYJ522M-l-M5 SS3YJ5--20-05 Stations Applicable blank plate ass'y SYJ500-10-1A 2 stations 02 P Port Rc(PT)1/8 .. .. 20 stations 20 R Port Rc(PT)1/8 Note) If more than 6 stations, supply air to both sides of P port and exhaust air from both sides of R port. 40 Type Applicable solenoid valve SYJ514-l SYJ514M-l

VQZ VZ VS VFN 4-4-25 Series SYJ500 Manifold for Internal Pilot Type How to Order Applicable solenoid valve SYJ512--M5 SYJ512M--M5 SYJ522--M5 SYJ522M--M5 A port M5 x 0.8 Type 20 SS3YJ5 20 05 Stations Bracket P, R port thread type + + + + Nil Nil 02 : 20 Rc G NPT NPTF 2 stations : 20 stations Without bracket Applicable blanking plate assembly SYJ500-10-1A R P 00F 00N 00T With bracket F P port

4" one-touch fitting) M5 0.8 1/8 NPTF Port size M5 0.8 A port X port Note1) M5 0.8 M5 0.8 M5 0.8 Body ported type SYJ5 2/SYJ5 2R 3.4 (0.19) Note 2) Valve effective area mm2(Cv) M5 : 3.3 (0.18) 1/8 : 4.8 (0.27) N3T, N7T: 3.8 (0.21) Base mounted type SYJ5 4/SYJ5 4R M5 : 3.8 (0.21) 1/8 : 4.7 (0.26) Note 1 : Only for external pilot Note 2 : Value when used on a manifold Proper Combinations of

Slave unit 75 Slave unit 03 Slave unit 01 Master unit ZW-31LM SI unit Master unit SI unit Master unit SI unit SI unit SHIELD SG L2 L1 SHIELD SG L2 L1 SHIELD SG L2 L1 SG L2 L1 + + FG + + FG + + + + + + SHIELD FG FG + Twisted pair wire with shield Class 3 ground Class 3 ground Class 3 ground Class 3 ground FG FG b) 3 wire type Wiring does not include signal ground line (SG).

(Including the mounted valves. ) 1.10-148 Manifold optionsSV5Q11OP, #1 to #3 VQ 1000/2000 Plug-in Unit Base Mounted EXH block base assembly VVQ1000-19A-(C3, C4, C6, M5) F P L Manifold block ass'y Electrical entry F1 F2 F3 P1 P2 P3 L0 For F kit (2 to 12 stations)/Double wiring For F kit (13 to 24 stations)/Double wiring For F kit (2 to 24 stations)/Single wiring For P, G, T, S kit (2 to 12

Refer to pages starting with 181 for mounting. 95 95 100 8(4)-6.2 B () () (170) A 110 20 95 95 () () (150) A B A B 100 200 300 400 500 600 Stroke Model LG1H212SC-700-F-X10 LG1H212SC-800-F-X10 LG1H212SC-900-F-X10 LG1H212SC-1000-F-X10 LG1H212SC-1200-F-X10 Stroke Model LG1H212SC100-F-X10 LG1H212SC200-F-X10 LG1H212SC300-F-X10 LG1H212SC400-F-X10 LG1H212SC500-F-X10 LG1H212SC600-F-X10 580 680

Refer to pages starting with 181 for mounting. 95 100 8(4)-6.2 B 95 ( ) ( ) (170) A 95 110 20 95 ( ) ( ) (150) A B 100 200 300 400 500 600 700 800 900 1000 1200 Stroke Model LG1H212SC-100-F LG1H212SC-200-F LG1H212SC-300-F LG1H212SC-400-F LG1H212SC-500-F LG1H212SC-600-F LG1H212SC-700-F LG1H212SC-800-F LG1H212SC-900-F LG1H212SC-1000-F LG1H212SC-1200-F 80 180 280 380 480 580 680 780 880

Port size M5 x 0.8 Rc 1/8 Rc 1/4 Series Assembly part no.

How to Order Valves 5 L N SX 5 1 20 01 Thread type Series A, B port size Nil Applicable series Rc Symbol Port size M5 x 0.8 3 SX3000 5 SX5000 G F M5 One-touch fitting for 4 C4 N 7 SX7000 NPT SX3000 One-touch fitting for 6 C6 NPTF T Type of actuation 1 8 01 1 2 position single One-touch fitting for 4 C4 Rated voltage SX5000 2 2 position double One-touch fitting for 6 C6 5 24 VDC 6 12 VDC 3

Body size Port size M5 M5 x 0.8 U10/32 10-32UNF 1 M5 x 0.8 10-32UNF AS 2 0 F A 1 1 M5 06 G Body size 1 AS 2 0 S F A 1 2 01 06 G Body size 2/3/4 Body size Made to Order Refer to page 484 for details. 2 1/8, 1/4 3 3/8 4 1/2 Push-lock type Type 2 Elbow 3 Universal Seal method Nil Without sealant S With sealant Note) Face seal method is used for the G thread type.

CN2 11 15 14 2 12 PF SG CR PP PG NP NG SD V24 SON LSN LSP ALM SG 3 12 13 9 10 7 8 20 17 11 LG 19 P5 4 OP 1 V+ 20 12 7 6 P5 LG MR MRR MD MDR SD 7 8 1 2 4 5 9 P5 LG MR MRR MD MDR SHD SG 7 8 1 2 4 9 P5 LG MR MRR MD MDR SHD Note 3) Detector 17 16 Plate 5 Note 2) Note 6) Be sure to connect the shielding wires to the ground plate inside the connector. 12 SG Note 1) Do not orient diodes incorrectly

CN2 11 15 14 2 12 PF SG CR PP PG NP NG SD V24 SON LSN LSP ALM SG 3 12 13 9 10 7 8 20 17 11 LG 19 P5 4 OP 1 V+ 20 12 7 6 P5 LG MR MRR MD MDR SD 7 8 1 2 4 5 9 P5 LG MR MRR MD MDR SHD SG 7 8 1 2 4 9 P5 LG MR MRR MD MDR SHD Note 3) Detector 17 16 Plate 5 Note 2) Note 6) Be sure to connect the shielding wires to the ground plate inside the connector. 12 SG Note 1) Do not orient diodes incorrectly