Refer to pages 11 and 12 regarding manifold additions. 9 Compact Direct Operated Series VDW10/20/30 2 Port Solenoid Valve for Water and Air Dimensions (mm) 1in = 25.4mm VV2DW3 (26.5) 23 2.5 20 14.7 Approx. 300 28 4.5 (24.5) 49 38 24.5 R2.25 L1 L2 L3 5.5 10.5 2-3/8 (IN port) (: Thread type) 1 Stations D side 2 3 4 5 n U side VDW33-*G-* VDW33-*G-* VDW33-*G-* VDW33-*G-* 83 34 5.5 21 16 n-1/
G E C T D DL S Z L 1, 2, 3, 4 (Only G)(Except G) 5, 6, 7 (Except DL)(Only T) (Only T) 17-4-13 2 Series VNB How to Order Seal material Body option Nil V Standard Vacuum pilot A B C NBR seals FKM seals EPR seals Thread type Bracket (valve size: 1/2/3/4.)
3 stns. 2 stns. + 3 stns. x 2 2 stns. x 2 + 3 stns. x 2 3 stns. x 1 2 stns. x 2 3 stns. x 2 3 stns. x 3 Note) Manifold base is consisted of the junction of 2 and 3 station bases.
Series: 350 [3 Port COM (Single Unit)], Voltage: 5VDC, Electrical Entry: Grommet / Tape winding, Orifice: 2 [250 (3 Port) Ø1.6; 350 (3 Port) Ø2], Port Size: 01 [1/8 (6A)], Thread: NPT, Material: Stainless Steel Body, NBR Seal Class B Coil, Option: Foot Bracket, CE Compliance: -
Series: 350 [3 Port COM (Single Unit)], Voltage: S (5VDC), Electrical Entry: G (Grommet / Tape winding), Orifice: 2 [250 (3 Port) Ø1.6; 350 (3 Port) Ø2], Port Size: 01 [1/8 (6A)], Thread: N (NPT), Material: G (Stainless Steel Body, NBR Seal Class B Coil), Option: F (Foot Bracket)
FG DG DB DA DG DB DA SLD FG b) 3 wire type Twisted pair wire with shield Class 3 ground Class 3 ground Class 3 ground Class 3 ground Power supply 24V 0V 24V 0V D G D G 24V 0V Slave unit (SI unit) Slave unit (SI unit) Slave unit Master unit (SI unit) SG B A SG B A FG SG B A FG SG B A FG FG Power supply 24V 0V Twisted pair wire with shield DG 36 EX120 Dedicated Output Serial Wiring Series
D G 24 V 0 V Slave unit (S1 unit) Slave unit (S1 unit) Slave unit Master station (S1 unit) FG SG B A FG SG B A FG SG B A SG B A 24 V 0 V Power supply FG Transmission line with shield Twisted pair wire Master unit SI unit SI unit FG DG DB DA FG DG DB DA DG DB DA Terminal resistor Terminal resistor SLD FG b) 3-wire type with shield Twisted pair wire Type 3 ground Type 3 ground Type 3 ground
DA FG DG DB DA DG DB DA Terminal resistor Terminal resistor SLD FG b) 3 line wiring Twisted pair line with shielding Power supply 24V 0V 24V 0V D G D G 24V 0V Master unit Type 3 grounding Type 3 grounding Type 3 grounding SI unit SI unit SI unit FG SG B A FG SG B A SG B A SG B A FG FG Power supply 24V 0V Twisted pair line with shielding DG Type 45 SI unit part nos.
D G 24 V 0 V Slave unit (S1 unit) Slave unit (S1 unit) Slave unit Master station (S1 unit) FG SG B A FG SG B A FG SG B A SG B A 24 V 0 V Power supply FG Transmission line Twisted pair wire with shielding Master unit SI unit SI unit Terminal resistor Terminal resistor FG DG DB DA FG DG DB DA DG DB DA SLD FG b) 3-wire type Twisted pair wire with shielding Type 3 ground Type 3 ground Type 3
3 0.5 3 3 3 Proximity switch types Home position switch 3 wire/NPN 3 wire/PNP 3 wire/NPN 3 wire/PNP 3 wire/NPN 3 wire/PNP 2 wire 3 wire/NPN 3 wire/PNP 2 wire N.O.
The electrical entry port {VQ1000: G(PF)1/2, VQ2000: G(PF)3/4} permits connection of conduit fittings. Max. 24 stations. Enclosure: dust-resistant/jetproof type (IP65) available.
CN2 11 15 14 2 12 PF SG CR PP PG NP NG SD V24 SON LSN LSP ALM SG 3 12 13 9 10 7 8 20 17 11 LG 19 P5 4 OP 1 V+ 20 12 7 6 P5 LG MR MRR MD MDR SD 7 8 1 2 4 5 9 P5 LG MR MRR MD MDR SHD SG 7 8 1 2 4 9 P5 LG MR MRR MD MDR SHD Note 3) Detector 17 16 Plate 5 Note 2) Note 6) Be sure to connect the shielding wires to the ground plate inside the connector. 12 SG Note 1) Do not orient diodes incorrectly
Standards RS-232C One thermo-chiller for one master RD 2 RD 2 SD 3 SD 3 Circuit diagram SG 5 SG 5 Master This product Do not connect with other pins. 5 9 6 1 D-sub 9-pin female (socket) type 334 HRL Series Dual Channel Refrigerated Thermo-chiller for Lasers Optional Accessories Consumables List Part no. Description Qty.
CN1 CN2 Shuts off 3 12 13 9 10 7 8 20 17 PF SG CR PP PG NP NG SD V24 SON LSN LSP ALM SG P5 19 OP 4 11 LG V+ 1 P5 LG MR MRR MD MDR SD 20 12 7 6 SG P5 LG MR MRR MD MDR SHD P5 LG MR MRR MD MDR SHD 7 8 1 2 4 5 9 7 8 1 2 4 9 Detector 17 16 Plate 5 (Note 2) 11 15 14 2 12 (Note 6) Connect the shielding wire securely to the ground plate inside the connector.
Signal contents RS-232C RS-485 1 Unused BUS+ 2 RD Unused 3 SD Unused 4 Unused Unused 5 SG SG 6-8 Unused Unused 9 Unused BUS 8 Contact b for output cutoff alarm (closed when alarm occurs) 5 4 3 2 1 3 9 Contact a for upper/lower temp. limit alarm (open when alarm occurs) 10 Common for upper/lower temp. limit alarm 4 11 Contact b for upper/lower temp. limit alarm (closed when alarm occurs) 12
V F Black 0 V G Shield 658 Stroke Reading Cylinder CE1 Series Construction 12, 20 32 @7 @4@8 @0 oi @3!
10, 12, 16 1/4, 3/8 50 RS Q G 500 15 63 RS H A 3/8, 16 1/2, 16 1/2, 16 3/4, 16 3/4, 16 1000 1500 2000 2500 3000 30 0 45 1,000 2,000 3,000 60 RZQ Maximum speed Vmax (mm/s) 75 89.5 80 MI W S 16 3/8, 1/2 500 24.5 = 0.7 3/8, 16 1/2, 16 3/4 3/4 3/4 3/8 1/2, 16 3/4 3/4 3/4 3/4 1000 1500 2000 2500 3000 500 1000 1500 2000 2500 3000 48.5 150 CEP1 80 72.5 96.5 0.5 120.5 100 0.1 0.3 CE1 106 38 50
V Red F 0 V Black G Shield 10-12-20 20 Stroke Reading Cylinder Series CE1 Construction 12, 20 32 @7 @4@8 @0 oi @3 !
V Red F 0 V Black G Shield 10-12-20 20 Stroke Reading Cylinder Series CE1 Construction 12, 20 32 @7 @4@8 @0 oi @3 !