New Products Guide 2 Air Preparation Equipment, Modular F. R. L., Air Tanks Fittings and Tubing Flow Control Equipment, Exhaust Filters Switches/Sensors Process Valves High Vacuum Equipment Temperature Control Equipment Pneumatic Instrumentation Process Gas Equipment Equipment CAT.E00-7A INDEX New Products Guide 2 Air Preparation Equipment/ Modular F. R. L./Air Tanks Refrigerated Air Dryer
Pressure gauge or pressure convertor Thermometer Differential pressure gauge or differential pressure converter d1 Pressure control d3 3d1 equipment Flow control 3d3 valve d2 Filter Air Flow meter Shut off 3d2 10d2 3d1 10d1 10d3 supply valve Pipe for measuring Equipment temperature for test Pipe for Pipe for measuring measuring pressure in the pressure in the downstream side upstream side
Pressure gauge or pressure converter Thermometer Differential pressure gauge or differential pressure converter Pressure control equipment d1 d3 3d1 Flow control valve 3d3 d2 Air Filter Shut off valve Flow meter 3d2 10d2 3d1 10d1 10d3 supply Pipe for measuring temperature Pipe for measuring pressure on the upstream side Test equipment Pipe for measuring pressure on the downstream side Fig
Pressure gauge or pressure convertor Thermometer Differential pressure gauge or differential pressure converter Pressure control equipment d1 d3 3d1 3d3 Flow control valve d2 Shut off valve Air supply Filter Flow meter 10d3 10d1 10d2 3d1 3d2 Pipe for measuring temperature Equipment for test Pipe for measuring pressure in the downstream side Pipe for measuring pressure in the upstream side
Pressure gauge or pressure convertor Thermometer Differential pressure gauge or differential pressure converter Pressure control equipment d1 d3 3d1 3d3 Flow control valve d2 Shut off valve Air supply Filter Flow meter 10d3 10d1 10d2 3d1 3d2 Pipe for measuring temperature Equipment for test Pipe for measuring pressure in the downstream side Pipe for measuring pressure in the upstream side
Pressure gauge or pressure convertor Thermometer Differential pressure gauge or differential pressure converter Pressure control equipment d1 d3 3d1 3d3 Flow control valve d2 Shut off valve Air supply Filter Flow meter 10d3 10d1 10d2 3d1 3d2 Pipe for measuring temperature Equipment for test Pipe for measuring pressure in the downstream side Pipe for measuring pressure in the upstream side
Function: 3 Position Closed Center, Piping: Base Mounted, Exhaust: Base, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115 VAC) 50/60Hz], Lead Wire: DIN Terminal w/Connector, Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, Port Size: 1/4, Thread: -, Made to Order: -, CE Approval: -
Function: 3 (3 Position Closed Center), Piping: 4 (Base Mounted), Exhaust: 4 (Base), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115 VAC) 50/60Hz], Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, Port Size: 02 (1/4)
Function: 3 (3 Position Closed Center), Piping: 4 (Base Mounted), Exhaust: 4 (Base), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115 VAC) 50/60Hz], Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, Port Size: 04 (1/2)
Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: AC110V, Specification: Standard, Valve Type: 5-Port Valve, Actuation: -, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 3-Position Closed Center, Applicable Cylinder Diameter(Ø): -, Pipe Port Type: [Rc (R)] Rc, Port Size: 1/2, Pressure Rating(MPa): 0.15 to 0.7, Driving Type: Pilot
Pressure gauge or pressure convertor Thermometer Differential pressure gauge or differential pressure converter Pressure control equipment d1 d33d1 Flow control valve 3d3 d2 Air supply Filter Shut off valve Flow meter 3d2 10d2 3d1 10d1 10d3 Pipe for measuring temperature Pipe for measuring pressure on the upstream side Test equipment Pipe for measuring pressure on the downstream side Fig.
Pressure gauge or pressure convertor Thermometer Differential pressure gauge or differential pressure converter Pressure control equipment d1 d33d1 Flow control valve 3d3 d2 Air supply Filter Shut off valve Flow meter 3d2 10d2 3d1 10d1 10d3 Pipe for measuring temperature Pipe for measuring pressure in the upstream side Equipment for test Pipe for measuring pressure in the downstream side
Pressure gauge or pressure convertor Thermometer Differential pressure gauge or differential pressure converter Pressure control equipment d1 d33d1 Flow control valve 3d3 d2 Air supply Filter Shut off valve Flow meter 3d2 10d2 3d1 10d1 10d3 Equipment for test Pipe for measuring temperature Pipe for measuring pressure in the upstream side Pipe for measuring pressure in the downstream side
0 3 0 3 0 3 0 Supply port Supply port Supply port P P P P P T T T T U T U U U U E L E E E E L S L L L S S S S L L L L L 6 9 6 9 6 9 6 9 6 9 IN IN IN MPa MPa MPa MPa MPa Right Left Right Bracket DIN rail mounting bracket DIN rail mounting bracket Stations 1 Stations 1 Stations 1 2 3 IISA2NSR-1B1 set (1 station manifold part number) ISA2-GE41P1 set (Air catch sensor part number) IISA2NSR-3D1
This is a legacy product, and replaced byVF5120-3D1-03
This is a legacy product, and replaced byVF3133-3D1-02
This is a legacy product, and replaced byVF3233-3D1-02
This is a legacy product, and replaced byVF3133-3D1-02N
This is a legacy product, and replaced byVF5120-3D1-03T, VALVE SOL/PILOT *LQA, VALVE, VF5000 SOL VALVE 4/5 PORT, GD, VF5000 BODY PT 3/8NPT (F), .83600 lb
0.3 0.2 0.1 0.3 0.2 0.1 0 MPa 0.4 0 MPa 0.4 0 MPa 0.4 0 MPa 0.4 0 MPa 0.4 Right Right Left Bracket DIN rail mounting bracket DIN rail mounting bracket Stations 1 Stations 1 Stations 1 2 3 IISA2NSR-1B1 set (1 station manifold part number) ISA2-GE41P1 set (Air catch sensor part number) IISA2NPL-1D1 set (1 station manifold part number) ISA2-GE41N 1 set (Air catch sensor part number) IISA2NSR-3D1