Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 04 (1/2), Thread: T (NPTF), Passage: B (Normally Open)
Pilot: Internal Pilot, Voltage: 110VAC 50/60HZ, Lead Wire: DIN Connector, Surge Suppressor: None, Port Size: 1/2, Thread: NPTF, Passage: Normally Open, Option: -, CE Compliant: -
dryer Applicable dryer Port size Rc E D D C A B Part No.
D D t D t t c e c c e e u u s u s s d i d i d i g g g o o o n n n r r r P P P A A A 1 1 9 9 9 9 9 9 w w 9 w 9 9 m I m I n n 9 9 9 u d u d a a a r u r u o s o F s tr F i e tr i e 9 9 9 D r r D r r r e e e e v v s 1 d d s 1 1 d o o i i n g n g n n n n a a H H n P n P g g r r o o i i s s d d e e u u D D c c t t d A d A r r w w a a 12-11-1 2 Courtesy of Steven Engineering, Inc.-230 Ryan Way,
, 4D, 6D, 8D Small How to Order Voltage Model Options (No options for standard specification models) 3D 4D 6D 8D C E H 1 IDU 2 4 6 L M R S T Voltage 1 100VAC (50Hz) 100 to 110VAC (60Hz) 200VAC (50Hz) 200 to 220VAC (60Hz) 2 Single phase 240VAC (50Hz) 220 to 240VAC (50Hz) 4 6 220VAC (50Hz) Model Air compressor Refrigerant 2.2kW 3.7kW 5.5kW 7.5kW 1 3D 4D 6D 8D R134a Model and voltage combinations
With external pilot specification (Pitch) P = 24 65.8 24 20 25 11 E 3/5 E 3/5 E 3 A E 3 A 4 A 4 A 4 A 4 A 4 4 A 4 A 4 A 4 A 4 13.7 14.5 35.8 35 58.3 74.8 B 2 B 2 B 2 B 2 B 2 P 1 P 1 P 1 B 2 B 2 B 2 B 2 B 2 P 1 One-touch fitting [1(P), 3/5(E) port] Applicable tubing O.D.: 12 N11 One-touch fitting [4(A), 2(B) port] Applicable tubing O.D.: 8, N9 10, N11 12 x PE X PE Rc 3/8 [1(P), 3(E) port]
P407090-1 P406090-3D MRHQ10D Switch holder B P406090-3S MRHQ10S P407060-1 P406090-3C MRHQ10C Switch case P406060-3D MRHQ16D P406060-3S MRHQ16S P406060-3C MRHQ16C P407080-3D MRHQ20D P407080-3S MRHQ20S Switch holder A P407080-3C MRHQ20C P408080-3D MRHQ25D Two of each part indicated at the left are included in a unit. Switches are not included with a unit.
EZ VFS1320-E/EZ VFS1420-E/EZ VFS1520-E/EZ Lead wire O.D.
(b) 1) Vb[V] 2) (Ib) Ib = Vb R [A] 3) (E) L lb2 E = 2 [J] 4) (Vi) (Ib)(Vi)(E) (Vi)[V](Vs)[V]Vi ViVs 5) () () = E Vi lb [S] 6) ()N (Ip) (Ip)(Ib) Ip/IbN[] (4) 13 3 13. 13.1.2 ( ) () LE--B S5 S6 S7 S8 50W 100W 200W 400W (1) () (4) DC 24 V 0 -10% [W] at 20 6.3 7.9 (6) [] 91.0 73.0 (6) [H] 0.15 0.18 [N m] 0.32 1.3 (2) [s] 0.03 0.03 (2) [s] 0.01 0.02 1 [J] 5.6 22 [J] 56 220 (5
Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: G (Grommet Lead Wire 0.3m), Surge Suppressor: S (Surge Suppressor), Port Size: 04 (1/2), Thread: T (NPTF), Passage: B (Normally Open), Option: E (Continuous Duty)
Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Port Size: 04 (1/2), Thread: T (NPTF), Passage: B (Normally Open), Option: E (Continuous Duty)
Pilot: Internal Pilot, Voltage: 24VDC, Lead Wire: Grommet Lead Wire 0.3m, Surge Suppressor: Surge Suppressor, Port Size: 1/2, Thread: NPTF, Passage: Normally Open, Option: Continuous Duty, CE Compliant: -
Pilot: Internal Pilot, Voltage: 110VAC 50/60HZ, Lead Wire: DIN Connector, Surge Suppressor: Light & Surge Suppressor, Port Size: 1/2, Thread: NPTF, Passage: Normally Open, Option: Continuous Duty, CE Compliant: -
Assembly 1) Terminal box e connected with housing r should be reinstated.
M12 connector pin number Wiring specication w r q e w w q e e r q r VG342(R)-X87 Internal pilot External pilot External pilot/With check valve 2(A) 2(A) 2(A) w r w r w r q e q e q e 3(R) 3(R) 3(R) w r w r w r q e q e q e 3(R) 3(R) 3(R) 1(P) X X Safety limit switch terminal [N.C.]
Take proper measures to prevent dust or foreign matter from accumulating in this area. (6) (3e) VQZ (3d) (3d) (3c) VZ (3) (9) (3a) VS (3e) (8) Electrical Connection VFN (9) For wiring to DIN terminal, connect the positive (+) polar side with connector terminal no. 1 and the negative () side with connector terminal no. 2 when the rated voltage is DC type. (3e) Magnifying figure (2a) Self-up
VZS VFS VS4 VQ7 EVS (1) VFN (4) (7) (5) (6) (3e) (3d) (3d) (3c) (3) (9) (3a) (3e) (8) (9) (3e) Magnifying figure (2a) Self-up screw 2 1 3 (2b) DlN Terminal (Connection) Solenoid is wired with male thread terminals of DIN connector as follows. Connect with corresponding terminals of the connector.