Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Port Size: 10 (1), Thread: T (NPTF), Passage: A (Normally Closed), Option: E (Continuous Duty)
Series VG342 is a 3 port pilot poppet solenoid valve and can be used as a selector or divider valve (external pilot). Actuation is changeable between N.C., N.O., or external pilot types. VG342 is possible to use in vacuum or under low pressures.
Series VG342 is a 3 port pilot poppet solenoid valve and can be used as a selector or divider valve (external pilot). Actuation is changeable between N.C., N.O., or external pilot types. VG342 is possible to use in vacuum or under low pressures.
Pilot: Internal Pilot, Voltage: 24VDC, Lead Wire: DIN Connector, Surge Suppressor: None, Port Size: 1, Thread: NPTF, Passage: Normally Closed, Option: -, CE Compliant: -
Pilot: Internal Pilot, Voltage: 110VAC 50/60HZ, Lead Wire: DIN Connector, Surge Suppressor: None, Port Size: 1, Thread: NPTF, Passage: Normally Closed, Option: -, CE Compliant: -
Pilot: Internal Pilot, Voltage: 12VDC, Lead Wire: DIN Connector, Surge Suppressor: Light & Surge Suppressor, Port Size: 1, Thread: NPTF, Passage: Normally Closed, Option: -, CE Compliant: -
Pilot: Internal Pilot, Voltage: 220VAC 50/60HZ, Lead Wire: DIN Connector, Surge Suppressor: Light & Surge Suppressor, Port Size: 1, Thread: NPTF, Passage: Normally Closed, Option: -, CE Compliant: -
Pilot: Internal Pilot, Voltage: 24VDC, Lead Wire: Grommet Lead Wire 0.3m, Surge Suppressor: None, Port Size: 1, Thread: NPTF, Passage: Normally Closed, Option: -, CE Compliant: -
Pilot: Internal Pilot, Voltage: 24VDC, Lead Wire: Grommet Lead Wire 0.3m, Surge Suppressor: Surge Suppressor, Port Size: 1, Thread: NPTF, Passage: Normally Closed, Option: -, CE Compliant: -
Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC24V, Specification: Standard / Lubrication Free, Valve Type: 3-Port Valve, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 2-Position Normally Closed, Pipe Port Type: NPTF, Port Size: 1, Pressure Rating(MPa): 02 to 0.9, Driving Type: Pilot Type Poppet,
Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 10 (1), Thread: T (NPTF), Passage: A (Normally Closed)
Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 10 (1), Thread: T (NPTF), Passage: A (Normally Closed)
Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Port Size: 10 (1), Thread: T (NPTF), Passage: A (Normally Closed)
Pilot: Internal Pilot, Voltage: 6 (12VDC), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Port Size: 10 (1), Thread: T (NPTF), Passage: A (Normally Closed)
Pilot: Internal Pilot, Voltage: 4 (220VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Port Size: 10 (1), Thread: T (NPTF), Passage: A (Normally Closed)
Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: G (Grommet Lead Wire 0.3m), Surge Suppressor: None, Port Size: 10 (1), Thread: T (NPTF), Passage: A (Normally Closed)
Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: G (Grommet Lead Wire 0.3m), Surge Suppressor: S (Surge Suppressor), Port Size: 10 (1), Thread: T (NPTF), Passage: A (Normally Closed)
Effective torque(35)Tf 10Ta=10I=100.0002/0.22 Static loadT s Effective torque10T a =0.157NmEffective torque Resistance loadTf OK Date 1 and Graph 1 Inertial loadT a Note:Substitute a numerical value of moment of inertai for I. Rotation time Confirm that it is within the adjustable 0.070.3s/90 0.2s/90 OK rotation time.
time (t): 0.3s; Rotation (): 90 Load weight (m): 0.15kg Distance between central axis and center of gravity (H): 30mm Required torque 2 Inertial load Confirm the type of load as shown below, and select an actuator that satisfies the required torque. . 10 x Ta = 10 x I x = 10 x 0.0002 x /0.3 Effective torque Ts Effective torque (3 to 5)Tf = 0.07Nm < Effective torque OK Effective torque 10Ta
Pilot: Internal Pilot, Voltage: 24VDC, Lead Wire: DIN Connector, Surge Suppressor: Light & Surge Suppressor, Port Size: 1, Thread: NPTF, Passage: Normally Closed, Option: Low Wattage 2WDC, CE Compliant: -