This is a legacy product. Please contact us for the latest version.sales@ocaire.com, HAND VALVE, VALVE, VH HAND VALVE, LF, VH BODY PT >3/4, 2.96301 lb
VH410-02 to 06 3 (Closed center) 1 (P) 3 (R) Rc 1/4: 45 4 3 VH401-02 to 06 VH411-02 to 06 3 (Exhaust center) Rc 3/8: 49 Rc 1/2: 55 VH402-02 to 06 VH412-02 to 06 2 (Position) 1/4 to 3/4 2 1 1.28 VH4 Handle Operation Angle and Air Flow Direction VH420-02 to 06 VH430-02 to 06 3 (Closed center) (Refer to the figures of piping direction to the right.)
VH410-02 to 06 3 (Closed center) 1 (P) 3 (R) Rc 1/4: 45 4 3 VH401-02 to 06 VH411-02 to 06 3 (Exhaust center) Rc 3/8: 49 Rc 1/2: 55 VH402-02 to 06 VH412-02 to 06 2 (Position) 1/4 to 3/4 2 1 1.28 VH4 Handle Operation Angle and Air Flow Direction VH420-02 to 06 VH430-02 to 06 3 (Closed center) (Refer to the figures of piping direction to the right.)
VH410-02 to 06 Rc1/4: 45(2.5) 4 3 3 (Exhaust center) VH401-02 to 06 VH411-02 to 06 Rc3/8: 49(2.7) Rc1/2: 55(3.1) 2 (Position) VH402-02 to 06 VH412-02 to 06 2 1 1.28 VH4 Handle operation angle and air flow direction 1/4 to 3/4 3 (Closed center) VH420-02 to 06 VH430-02 to 06 (Refer to figures of porting direction in the right.) 3 (Exhaust center) VH421-02 to 06 VH431-02 to 06 Rc3/4: 58(3.2
3 4 2 1 VH422-N02 to N06 VH432-N02 to N06 2 (Position) Flow direction 2 Flow direction 4 Flow direction 2 Flow direction 4 90 45 45 3/4" 185(10.2) 1 2 21.34 (9.7) VH6 VH600-N06,N10 3 (Closed center) 3/4", 1" 1" 194(10.5) 3 4 2 How To Order Series VH How to Order VH 2 0 1 02 N Options Hand valve R In/Out Reverse Valve model (Cv) Port size (NPT) 2 3 4 6 (0.4) (1.1) (3.2) (10.5) 02 03 04 06
Main Body Shape: Block Horizontal Type, Number of Ports: 4-Port, Number of Switching Positions: 3-Position Closed Center, Operation Status Retention: Retention, Switching Operation: Manual Lever, Effective Sectional Area(mm2): 64.58, Effective Sectional Area Class(mm2): Up to 70, Pipe Port Type: Rc (R), Plumbing Thread Nominal: 1/2, Mounting Method: Bottom, Plumbing
Main Body Shape: Block Horizontal Type, Number of Ports: 4-Port, Number of Switching Positions: 3-Position Closed Center, Operation Status Retention: Retention, Switching Operation: Manual Lever, Effective Sectional Area(mm2): 64.58, Effective Sectional Area Class(mm2): Up to 70, Pipe Port Type: G, Plumbing Thread Nominal: 1/2, Mounting Method: Bottom, Plumbing Type
Main Body Shape: Block Horizontal Type, Number of Ports: 4-Port, Number of Switching Positions: 3-Position Closed Center, Operation Status Retention: Retention, Switching Operation: Manual Lever, Effective Sectional Area(mm2): 68.26, Effective Sectional Area Class(mm2): Up to 70, Pipe Port Type: G, Plumbing Thread Nominal: 3/4, Mounting Method: Bottom, Plumbing Type
Main Body Shape: Block Horizontal Type, Number of Ports: 4-Port, Number of Switching Positions: 3-Position Closed Center, Operation Status Retention: Retention, Switching Operation: Manual Lever, Effective Sectional Area(mm2): 53.50, Effective Sectional Area Class(mm2): Up to 60, Pipe Port Type: NPT, Plumbing Thread Nominal: 1/4, Mounting Method: Bottom, Plumbing Type
Main Body Shape: Block Horizontal Type, Number of Ports: 4-Port, Number of Switching Positions: 3-Position Closed Center, Operation Status Retention: Retention, Switching Operation: Manual Lever, Effective Sectional Area(mm2): 57.20, Effective Sectional Area Class(mm2): Up to 60, Pipe Port Type: NPT, Plumbing Thread Nominal: 3/8, Mounting Method: Bottom, Plumbing Type
Main Body Shape: Block Horizontal Type, Number of Ports: 4-Port, Number of Switching Positions: 3-Position Closed Center, Operation Status Retention: Retention, Switching Operation: Manual Lever, Effective Sectional Area(mm2): 64.58, Effective Sectional Area Class(mm2): Up to 70, Pipe Port Type: NPT, Plumbing Thread Nominal: 1/2, Mounting Method: Bottom, Plumbing Type
Main Body Shape: Block Horizontal Type, Number of Ports: 4-Port, Number of Switching Positions: 3-Position Closed Center, Operation Status Retention: Retention, Switching Operation: Manual Lever, Effective Sectional Area(mm2): 68.26, Effective Sectional Area Class(mm2): Up to 70, Pipe Port Type: NPT, Plumbing Thread Nominal: 3/4, Mounting Method: Bottom, Plumbing Type
Size: 400, Piping and Mounting: Bottom Ported Body Mount, No.of Positions: 3 Position Closed Center, Thread: Rc(PT), Port Size: 3/8, Rod Handle: -, Made to Order: -
Size: 4 (400), Piping and Mounting: 2 (Bottom Ported Body Mount), No.of Positions: 0 (3 Position Closed Center), Thread: Rc(PT), Port Size: 03 (3/8)
Size: 4 (400), Piping and Mounting: 2 (Bottom Ported Body Mount), No.of Positions: 0 (3 Position Closed Center), Thread: N (NPT), Port Size: 04 (1/2)
Size: 4 (400), Piping and Mounting: 2 (Bottom Ported Body Mount), No.of Positions: 0 (3 Position Closed Center), Thread: N (NPT), Port Size: 06 (3/4)
Size: 4 (400), Piping and Mounting: 2 (Bottom Ported Body Mount), No.of Positions: 0 (3 Position Closed Center), Thread: F [G(PF)], Port Size: 06 (3/4)
Size: 4 (400), Piping and Mounting: 2 (Bottom Ported Body Mount), No.of Positions: 0 (3 Position Closed Center), Thread: N (NPT), Port Size: 02 (1/4)
Size: 4 (400), Piping and Mounting: 2 (Bottom Ported Body Mount), No.of Positions: 0 (3 Position Closed Center), Thread: F [G(PF)], Port Size: 04 (1/2)
Size: 4 (400), Piping and Mounting: 2 (Bottom Ported Body Mount), No.of Positions: 0 (3 Position Closed Center), Thread: Rc(PT), Port Size: 04 (1/2)