Size: 5 [ø32(ø22)], Valve Type: 1 [NC (Operating Pressure 0.5MPa)], Sealant: A (NBR Seal), Body Material: Standard, Pilot System Option: Standard, Thread: Rc(PT), Port Size: 32A (1 1/4), Voltage: 5 (24VDC), Lead Wire: DZ (DIN Terminal w/Light & Surge Voltage Suppressor)
Compatible Fluid: Air / Water / Vacuum / Oil / Gas, Operating Environment: Standard, Type: Electromagnetic Type, Number of Solenoids: Single Solenoid, Switching Type: Normally Closed, Application: Individual Item, Connection Type: [Rc (R)] Rc, Plumbing Thread Nominal: 1 1/4, Tube Flange Nominal: -, Operating Temperature Range(°C): -5~50, Driving Type: Pilot Type, Operating Pressure Difference
Option Stainless steel Standard Brass BC6 Brass BC6 NBR Standard Brass BC6 Brass BC6 NBR Option Stainless steel 10A to 25A 15A to 25A Body Body q q 32A to 50A 32A to 50A Stainless steel Stainless steel 10A to 25A 32A to 50A 15A to 25A 32A to 50A Bonnet Bonnet w w FKM/EPDM Stainless steel, FKM Stainless steel, EPDM FKM/EPDM Stainless steel, FKM Stainless steel, EPDM Stainless steel, Brass
L 230 VAC 7 32A N.C. Q CAC408 35 32A Flange M Conduit terminal 24 VDC E N.O. With surge voltage suppressor N 100 VAC 8 40A N.C. R CAC408 40 40A Flange P 110 VAC F N.O. Q 200 VAC 9 50A N.C. S CAC408 50 50A Flange R 230 VAC G N.O.
Thread T F N Thread Rc(PT) NPTF G(PF) NPT Refer to p.4.0-15 for ordering coil only. 1 For 32A For 40A For 50A 32 40 50 Flange Refer to table q for configuration.
effective area Q=11S P(P2+1.033).kg/h Equation in the domain of sonic flow Calculation by Cv factor Q=98.9Cv(p1+1.033).kg/h Calculation by effective area Q=5.51S(P1+1.033).kg/h 4.2-38 VND Flow Characteristics Water/VND 2 to 7 should be N.O. to suppress water hammer.
Size: 5 [ø32(ø22)], Valve Type: 1 [NC (Operating Pressure 0.5MPa)], Sealant: NBR Seal, Body Material: Standard, Pilot System Option: Standard, Thread: Rc(PT), Port Size: 1 1/4, Voltage: 12VDC, Lead Wire: DIN Terminal w/Light & Surge Voltage Suppressor, Manual Override: Non-locking Push Style, Bracket: None, X200: No, CE Compliance: CE Compliance
Size: 5 [ø32(ø22)], Valve Type: 1 [NC (Operating Pressure 0.5MPa)], Sealant: A (NBR Seal), Body Material: Standard, Pilot System Option: Standard, Thread: Rc(PT), Port Size: 32A (1 1/4), Voltage: 5 (24VDC), Lead Wire: D (DIN Terminal), Manual Override: Non-locking Push Style, Bracket: None, X200: No, CE Compliance: Q (CE Compliance)
Size: 5 [ø32(ø22)], Valve Type: 1 [NC (Operating Pressure 0.5MPa)], Sealant: A (NBR Seal), Body Material: Standard, Pilot System Option: Standard, Thread: Rc(PT), Port Size: 32A (1 1/4), Voltage: 6 (12VDC), Lead Wire: DZ (DIN Terminal w/Light & Surge Voltage Suppressor), Manual Override: Non-locking Push Style, Bracket: None, X200: No, CE Compliance: Q (CE Compliance)
Compatible Fluid: Air / Water / Vacuum / Oil / Gas, Operating Environment: Standard, Type: Electromagnetic Type, Number of Solenoids: Single Solenoid, Switching Type: Normally Closed, Application: Individual Item, Connection Type: [Rc (R)] Rc, Plumbing Thread Nominal: 1 1/4, Tube Flange Nominal: -, Operating Temperature Range(°C): -5~50, Driving Type: Pilot Type, Operating Pressure Difference
Equipment w e q Digital flow switch for air Air leakage tester Compact manometer Equipment Equipment Equipment Equipment q w Air leakage tester Main Points w Measure air leakage rate and air blow rate Air leakage tester. (Made to order) Page 133 q Measure main line and branch line flow rates. Digital flow switch for air Series PFA Page 84 e Measure air blow rate.
Description Size Standard Brass BC6 Brass BC6 NBR Option Stainless steel Standard Brass BC6 Brass BC6 NBR Option Stainless steel 10A to 25A 15A to 25A Body Body q q 32A to 50A 32A to 50A Stainless steel Stainless steel 10A to 25A 32A to 50A 15A to 25A 32A to 50A Bonnet Bonnet w w FKM/EPDM Stainless steel, FKM Stainless steel, EPDM FKM/EPDM Stainless steel, FKM Stainless steel, EPDM Stainless
r e w q r e w q VG VP S070 VQ VKF N.C.
Option Stainless steel Standard Brass BC6 Brass BC6 NBR Standard Brass BC6 Brass BC6 NBR Option Stainless steel 10A to 25A 15A to 25A Body Body q q 32A to 50A 32A to 50A Stainless steel Stainless steel 10A to 25A 32A to 50A 15A to 25A 32A to 50A Bonnet Bonnet w w FKM/EPDM Stainless steel, FKM Stainless steel, EPDM FKM/EPDM Stainless steel, FKM Stainless steel, EPDM Stainless steel, Brass
Symbol Parts name VEX11001 02 VEX12001 02 VEX13002 03 04 04 06 10 VEX150VEX17010 12 VEX19014 20 VEX3-32A VEX5-32A VEX7-32A VEX9-32A VEX1-18-1A G27-10-01 G36-10-01 B F G Bracket (with bolt and washer) Air operated External pilot solenoid G46-10-01 VEX1-18-2A Pressure gauge (1) Note 1) When requring the gauge except mentioned above, specify the model number.
623 A VNC Series How to Order Pilot Solenoid Valves Valve size 1 Valve size 2 to 9 1 Q SF4 5 D 5 D 23 Q VO307 CE-compliant Coil rated voltage CE-compliant Coil rated voltage CE-compliant Nil Q 1 2 3 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz CE-compliant Nil Q 1 2 3 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60
In the case of liquids: P Q = 53 Kv (9) G Q : Flow rate [L/min] Kv : Flow coefficient [m3/h] DP : Pressure difference [MPa] G : Relative density [water = 1] In the case of saturated aqueous vapor: Q = 232 Kv P (P2 + 0.1) (10) Q : Flow rate [kg/h] Kv : Flow coefficient [m3/h] DP : Pressure difference [MPa] P1 : Upstream pressure [MPa]: DP = P1 P2 P2 : Downstream pressure [MPa] 57 Solenoid
-20(-Q) 10-SS5YJ5-20P(-Q) Applicable manifold base 10-SS5YJ5-40(-Q) 10-SS5YJ5-41(-Q) 10-SS5YJ5-42(-Q) 10-SS5YJ5-43(-Q) 10-SS5YJ5-41P(-Q) 10-SS5YJ5-43P(-Q) Applicable manifold base Type 10-SS5YJ5-41(-Q) Type 10-SS5YJ5-42(-Q) Type 10-SS5YJ5-43(-Q) Type 10-SS5YJ5-41P(-Q) Type 10-SS5YJ5-43P(-Q) Caution Mounting screw tightening torque M2.5: 0.45 Nm Use caution to the assembly orientation
Note 3) Vacuum pilot type CE-compliant pilot solenoid valves will become VO307VD DZ-Q. 2 1 1 2 569 A VNB Series How to Order Pilot Solenoid Valves Valve size 1/2/3/4 Valve size 5/6/7 and vacuum pilot type VO307 Q 1 5 D SF4 5 D 23 Q Body option CE-compliant CE-compliant Coil rated voltage CE-compliant Nil Q Standard Vacuum pilot Nil V CE-compliant Nil Q 1 2 3 Note 1) 100 VAC 50/60 Hz 200