SMC Corporation of America
Elite Part Number Search
Search Results "VQ4000-PW-B03N"

Model: VQ4000, Porting Specificaitons: B (Bottom Ported), Port Size: 03 (3/8), Thread: N (NPT), CE, UKCA Compliant: Q (CE/UKCA-compliant)

Model: VQ4000, Porting Specificaitons: Bottom Ported, Port Size: 3/8, Thread: NPT, CE, UKCA Compliant: CE/UKCA-compliant

Please contact us for the latest version.sales@ocaire.com, SUBPLATE, VALVE, VQ4000 VALVE, SOL 4/5-PORT, 22, VQ4000 NO SIZE RATING, 1.07548 lb

VQ valves are ideal for applications requiring high speed, frequent operation, stable response time and long service life. Innovative mounting methods allow valves to be changed without entirely disassembling the manifold. Built-in one-touch fittings save piping time and labor. Fluid: air/inert gas, Operating pressure range: 0.15 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal

www.stevenengineering.com I S E E I N S I D E F R O N T C O V E R F O R FOR FURTHER TECHNICAL DETAILS ON THIS PRODUCT REQUEST CATALOG REFERENCE E137, E138, N238, N239 DETAILS OF YOUR LOCAL SALES OFFICE 2.42 SOLENOID VALVES SERIES VQ4000 5 PORT METAL SEAL/RUBBER SEAL BASE MOUNTED / PLUG IN TYPE SERIES VQ4000 High Speed and Long Life Compact Design with Large Flow Capacity Various Centralized

B 34 38 HG PA 2 10 Counterbore depth C MM thread depth M HG 2-P d D 4-J x K (Depth) 4-LD GP PW QW GP PW PB W HT HT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com HS 14 HA HP H NN G G L Q + Stroke HS 14 Auto switch A HA HP H Auto switch mounting rail can also be