Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period.Supply pressure: 0 to 1.0 MPa, Signal pressure: 0.25 to 0.8MPa, Time delay: 0.5 to 60s, Operating and fluid temp: -5 to 60C (no freezing), Effective area (Cv): 0.14, VALVE, TIME DELAY, VALVE, VR CHECK VALVE, DI, VR BODY PT 1/8,
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period.Supply pressure: 0 to 1.0 MPa, Signal pressure: 0.25 to 0.8MPa, Time delay: 0.5 to 60s, Operating and fluid temp: -5° to 60°C (no freezing), Effective area (Cv): 0.14, "VALVE, CHECK VALVE
VR2110-01 Model Supply pressure 0.1 to 1.0 MPa Signal pressure 0.25 to 0.8 MPa SA 0.5 to 60 s Time delay Repeatability 10% F.S.
VR2110-01 Model Supply pressure 0.1 to 1.0 MPa Signal pressure 0.25 to 0.8 MPa SA 0.5 to 60 s Time delay Repeatability 10% F.S.
Supply Pressure 0 ~ 1MPa / 0 ~ 145 PSI Signal Pressure 0.25 ~ 0.8MPa / 32 ~ 116PSI Time Delay 0.5 ~ 60 Sec 2.5mm2 (0.14) Effective Orifice (Cv Factor) Port Size 1/8 PT / NPT D I M E N S I O N S T I M E D E L AY V A LV E S Y M B O L S H O W T O O R D E R T I M E D E L AY V A LV E NVR2110-N01 (1/8 NPT) VR2110-01 (1/8 PT) SHUTTLE VALVE SERIES (N)VR1210, (N)VR1220 T E C H N I C A L SPECIFICATIONS
Supply Pressure 0 ~ 1MPa / 0 ~ 145 PSI Signal Pressure 0.25 ~ 0.8MPa / 32 ~ 116PSI Time Delay 0.5 ~ 60 Sec 2.5mm2 (0.14) Effective Orifice (Cv Factor) Port Size 1/8 PT / NPT D I M E N S I O N S T I M E D E L AY V A LV E S Y M B O L S H O W T O O R D E R T I M E D E L AY V A LV E NVR2110-N01 (1/8 NPT) VR2110-01 (1/8 PT) SHUTTLE VALVE SERIES (N)VR1210, (N)VR1220 T E C H N I C A L SPECIFICATIONS
3 01.0MPa 0.250.8MPa 0.560s (*) 10 (%) F.S. oC( -560 3/ (s C (dm 0.6 [1 (P) 2 (A) ] 0.5 [2 (A) 3 (R) ] bar) ) b 0.2 [1 (P) 2 (A) ] 0.15 [2 (A) 3 (R) ] Rc, NPT, G1/8 ON Delay 480g (*) 4 4 V R 2 1 1 0 01 01 Rc 1/8 N01 NPT 1/8 F01 F01 2 G 1/8 9 5 VR 1 ON Delay 0.560 () () 1 ON OFF 6 (1) 2 0.5MPa 2 10 (2) VR2110 3 )0.25MPa A 60sec (), (S) 0.8MPa 40sec B (3) (MPa) 3 OFF 1
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period.Supply pressure: 0 to 1.0 MPa, Signal pressure: 0.25 to 0.8MPa, Time delay: 0.5 to 60s, Operating and fluid temp: -5 to 60C (no freezing), Effective area (Cv): 0.14, VALVE, TIME DELAY, VALVE, VR CHECK VALVE, DI, VR BODY PT 1/8,
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period.3 port check valve, Max. operating pressure: 1.0MPa, Ambient and fluid temp: -5 to 60C, Effective area (Cv): 0.38 to 0.81, SHUTTLE VALVE, VALVE, VR CHECK VALVE, FI, VR BODY PT 1/4, .10542 lb
(0.38) 3 Balanced Poppet 10.8 (0.6) 5 Rubber Spool 9.9 (0.55) 5 Metal Spool 18 (1) 5 18 (1) 5 6 (0.33) 3 Rubber Spool Metal Spool Balanced Poppet Dual pressure available only on external pilot. 3.5-2 Series VM Related Products No.of Ports Effective Area (mm2) (Cv) Function VR1210 Shuttle Valve 7 (0.38) 3 Dimensions (mm) VR1210: 17.2 X 38 X 29 VR1220: 21.2 X 50 X 38 VR1220 15 (0.81) 3 VR2110
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period.3 port check valve, Max. operating pressure: 1.0MPa, Ambient and fluid temp: -5 to 60C, Effective area (Cv): 0.38 to 0.81, SHUTTLE VALVE W/O FITTING, VALVE, VR CHECK VALVE, C7, VR BODY PT 1/8NPT, .06708 lb
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period.Supply pressure: 0 to 1.0 MPa, Signal pressure: 0.25 to 0.8MPa, Time delay: 0.5 to 60s, Operating and fluid temp: -5 to 60C (no freezing), Effective area (Cv): 0.14, VALVE, TIME DELAY, VALVE, VR CHECK VALVE, DI, VR BODY PT 1/8,
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period.Shuttle valve with one-touch fitting, Maximum operating pressure: 1MPa (145 psi), Minimum operating pressure: 0.05MPa (7 psi), Proof pressure: 1.5MPa (218 psi), Ambient and fluid temp: -5 to 60C (23 to 140F) (with no freezing), SHUTTLE
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period.3 port check valve, Max. operating pressure: 1.0MPa, Ambient and fluid temp: -5 to 60C, Effective area (Cv): 0.38 to 0.81, SHUTTLE VALVE W/O FITTING, VALVE, VR CHECK VALVE, FI, VR BODY PT 1/4, .11252 lb
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period.Shuttle valve with one-touch fitting, Maximum operating pressure: 1MPa (145 psi), Minimum operating pressure: 0.05MPa (7 psi), Proof pressure: 1.5MPa (218 psi), Ambient and fluid temp: -5 to 60C (23 to 140F) (with no freezing), SHUTTLE
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period.Supply pressure: 0 to 145 psi, Signal pressure: 36.25 to 116 psi, Time delay: 0.5 to 60s, Operating and fluid temp: 23 to 140 F (no freezing), Effective area (Cv): 0.14, VALVE, TIME DELAY, VALVE, VR CHECK VALVE, CI, VR BODY PT 1
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period.AND valve with one-touch fitting, Maximum operating pressure: 1MPa (145 psi), Minimum operating pressure: 0.05MPa (7 psi), Proof pressure: 1.5MPa (218 psi), Ambient and fluid temp: -5 to 60C (23 to 140F) (with no freezing), AND VALVE
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period.Shuttle valve with one-touch fitting, Maximum operating pressure: 1MPa (145 psi), Minimum operating pressure: 0.05MPa (7 psi), Proof pressure: 1.5MPa (218 psi), Ambient and fluid temp: -5 to 60C (23 to 140F) (with no freezing), SHUTTLE
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period.AND valve with one-touch fitting, Maximum operating pressure: 1MPa (145 psi), Minimum operating pressure: 0.05MPa (7 psi), Proof pressure: 1.5MPa (218 psi), Ambient and fluid temp: -5 to 60C (23 to 140F) (with no freezing), AND VALVE