T Link Mini System Type R1, R2 OMRON Corporation CompoBus/S Type Q DeviceNet 1 SETTINGS PWR MOD/NET STATION NO. ADDRESS NO.
To avoid this, indicate positions of manifold blocks for single wiring specification (S) and double wiring specification (D) on the manifold specification sheet. (Note that double, 3 or 4 position valves cannot be used for manifolds blocks with single wiring specification (S).) 1.
Kit type S S Kit (Decentralized wiring type serial kit) Kit (I/O serial kit) IP67 protection IP67 protection Serial unit: EX250 Serial unit: EX500 SDTA SDTB SDTC SDTD SD0 SDQ SDN SDV SDY SD0A SDA1 Without SI unit DeviceNet PROFIBUS-DP CC-Link CANopen AS-i, 8 in/8 out, 31 slave modes, 2 power supply systems 1 to 4 stations (8 stations) Serial kit without SI unit Serial kit for Remote I/O 1
In addition, SMC now offers a light weight, large capacity mini ISO valve (size 01).Manifold for series VSR/S8-4 valves (size 01), Conforms to ISO 15407-2 , 1 to 12 stations as standard (depending on S kit) , G port thread is applicable to ISO 1179-1, "MFLD, VP7, 4/5 PORT SOLENOID VALVE, N lb
Size: 01(Size 26mm), Stations: 1 Station, A, B Port: Side, 1/4, Port Thread: NPTF, SI Unit: Serial Kit for DeviceNetâ„¢, PROFIBUS-DP, CC-LINK, EtherNet/IPâ„¢, End Plate: w/o SI Unit/End Plate, SI Unit COM: -COM, Number of Input Blocks: w/o SI Unit/Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: -, X Option: -, CE Compliant: -
Size: 01(Size 26mm), Stations: 4 Stations, A, B Port: 02 (Side, 1/4), Port Thread: T (NPTF), SI Unit: SD0 (EX250/500 Serial Kit w/o SI Unit), End Plate: w/o SI Unit/End Plate, SI Unit COM: +COM, Number of Input Blocks: w/o SI Unit/Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: S (Direct Exhaust w/Built-in Silencer)
Size: 01(Size 26mm), Stations: 6 Stations, A, B Port: 02 (Side, 1/4), Port Thread: T (NPTF), SI Unit: SD0 (EX250/500 Serial Kit w/o SI Unit), End Plate: w/o SI Unit/End Plate, SI Unit COM: +COM, Number of Input Blocks: w/o SI Unit/Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: S (Direct Exhaust w/Built-in Silencer)
Size: 01(Size 26mm), Stations: 8 Stations, A, B Port: 02 (Side, 1/4), Port Thread: T (NPTF), SI Unit: SD0 (EX250/500 Serial Kit w/o SI Unit), End Plate: w/o SI Unit/End Plate, SI Unit COM: +COM, Number of Input Blocks: w/o SI Unit/Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: S (Direct Exhaust w/Built-in Silencer)
Size: 01(Size 26mm), Stations: 10 Stations, A, B Port: 02 (Side, 1/4), Port Thread: T (NPTF), SI Unit: SD0 (EX250/500 Serial Kit w/o SI Unit), End Plate: w/o SI Unit/End Plate, SI Unit COM: +COM, Number of Input Blocks: w/o SI Unit/Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: S (Direct Exhaust w/Built-in Silencer)
Size: 01(Size 26mm), Stations: 4 Stations, A, B Port: Side, 1/4, Port Thread: NPTF, SI Unit: EX250/500 Serial Kit w/o SI Unit, End Plate: w/o SI Unit/End Plate, SI Unit COM: +COM, Number of Input Blocks: w/o SI Unit/Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: Direct Exhaust w/Built-in Silencer, X Option: -, CE Compliant: -
Size: 01(Size 26mm), Stations: 6 Stations, A, B Port: Side, 1/4, Port Thread: NPTF, SI Unit: EX250/500 Serial Kit w/o SI Unit, End Plate: w/o SI Unit/End Plate, SI Unit COM: +COM, Number of Input Blocks: w/o SI Unit/Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: Direct Exhaust w/Built-in Silencer, X Option: -, CE Compliant: -
Size: 01(Size 26mm), Stations: 8 Stations, A, B Port: Side, 1/4, Port Thread: NPTF, SI Unit: EX250/500 Serial Kit w/o SI Unit, End Plate: w/o SI Unit/End Plate, SI Unit COM: +COM, Number of Input Blocks: w/o SI Unit/Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: Direct Exhaust w/Built-in Silencer, X Option: -, CE Compliant: -
Size: 01(Size 26mm), Stations: 10 Stations, A, B Port: Side, 1/4, Port Thread: NPTF, SI Unit: EX250/500 Serial Kit w/o SI Unit, End Plate: w/o SI Unit/End Plate, SI Unit COM: +COM, Number of Input Blocks: w/o SI Unit/Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: Direct Exhaust w/Built-in Silencer, X Option: -, CE Compliant: -
This is a legacy product, and replaced bySY5200-5U1-W1-02T-NA NEW SY5000 VALVE. VALVE, SOL. VALVE. NEW SY5000 NO SIZE RATING. 2.866 lb. 2I.
Size: 01(Size 26mm), Stations: 4 Stations, A, B Port: 02 (Side, 1/4), Port Thread: T (NPTF), SI Unit: SD0 (EX250/500 Serial Kit w/o SI Unit), End Plate: w/o SI Unit/End Plate, SI Unit COM: +COM, Number of Input Blocks: w/o SI Unit/Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block
Size: 01(Size 26mm), Stations: 6 Stations, A, B Port: 02 (Side, 1/4), Port Thread: T (NPTF), SI Unit: SD0 (EX250/500 Serial Kit w/o SI Unit), End Plate: w/o SI Unit/End Plate, SI Unit COM: +COM, Number of Input Blocks: w/o SI Unit/Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block
Size: 01(Size 26mm), Stations: 8 Stations, A, B Port: 02 (Side, 1/4), Port Thread: T (NPTF), SI Unit: SD0 (EX250/500 Serial Kit w/o SI Unit), End Plate: w/o SI Unit/End Plate, SI Unit COM: +COM, Number of Input Blocks: w/o SI Unit/Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block
Size: 01(Size 26mm), Stations: 7 Stations, A, B Port: 02 (Side, 1/4), Port Thread: T (NPTF), SI Unit: SD0 (EX250/500 Serial Kit w/o SI Unit), End Plate: w/o SI Unit/End Plate, SI Unit COM: +COM, Number of Input Blocks: w/o SI Unit/Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block
Size: 01(Size 26mm), Stations: 4 Stations, A, B Port: Side, 1/4, Port Thread: NPTF, SI Unit: EX250/500 Serial Kit w/o SI Unit, End Plate: w/o SI Unit/End Plate, SI Unit COM: +COM, Number of Input Blocks: w/o SI Unit/Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: -, X Option: -, CE Compliant: -
Size: 01(Size 26mm), Stations: 6 Stations, A, B Port: Side, 1/4, Port Thread: NPTF, SI Unit: EX250/500 Serial Kit w/o SI Unit, End Plate: w/o SI Unit/End Plate, SI Unit COM: +COM, Number of Input Blocks: w/o SI Unit/Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: -, X Option: -, CE Compliant: -